Hemorrhage Risk after Stereotactic Radiosurgery of Cerebral Arteriovenous Malformations
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
To analyze the effect of stereotactic radiosurgery on the hemorrhage rate of arteriovenous malformations (AVMs), we reviewed the clinical and angiographic characteristics of 315 patients with AVMs before and after radiosurgery. One hundred ninety-six patients sustained 263 bleeds in 10,939 patient-years before radiosurgery, for an annual nonfatal hemorrhage rate of 2.4%. Clinical follow-up after radiosurgery was available in 312 patients (mean, 47 +/- 20 mo); follow-up > or = 24 months was obtained in 295 patients (94%). Twenty-one patients had AVM bleeds at a median of 8 months (range, 1-60 mo) after radiosurgery. Two additional patients had three aneurysmal bleeds (at 5, 27, and 32 mo, respectively) for a 7.4% total risk of hemorrhage per patient. The actuarial hemorrhage rate until AVM obliteration was 4.8% per year (95% confidence interval, 2.4-7.0%) during the first 2 years after radiosurgery and 5.0% per year (95% confidence interval, 2.3-7.3%) for the third to fifth years after radiosurgery. Multivariate analysis of clinical and angiographic factors demonstrated that the presence of an unsecured proximal aneurysm was associated with an increased risk of postradiosurgical hemorrhage (relative risk, 4.56; 95% confidence interval, 1.77-11.70%; P < 0.001). No AVM hemorrhages were observed after radiosurgery in seven patients with intranidal aneurysms. No protective effect against hemorrhage was observed in patients who received an "optimal" radiation dose (> or = 25 Gy to the AVM margin) compared with patients who received < 25 Gy to the AVM margin (P = 0.36). No patient suffered a hemorrhage after angiography had confirmed complete obliteration (n = 140) or suffered from an early draining vein without residual nidus (n = 19). Stereotactic radiosurgery was not associated with a significant change in the hemorrhage rate of AVMs during the latency interval before obliteration. No protective benefit was conferred on patients who had incomplete nidus obliteration in early (< 60 mo) follow-up after radiosurgery. AVM patients with unsecured proximal aneurysms should have aneurysms obliterated either before radiosurgery or at the time of surgical resection of their AVMs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Peto, R., Pike, M. C., Armitage, P., Breslow, N. E., Cox, D. R., Howard, S. V., Mantel, N., McPherson, K., Peto, J., & Smith, P. G. (1977) · British Journal of Cancer · doi:10.1038/bjc.1977.1 · Cited by 8,285
A Proposed Grading System for Arteriovenous Malformations
Spetzler, R. F., & Martin, N. A. (1986) · CRC Press eBooks · doi:10.1201/9781003416197-14 · Cited by 2,496
Ondra, S. L., Troupp, H., George, E. D., & Schwab, K. (1990) · Journal of Neurosurgery · doi:10.3171/jns.1990.73.3.0387 · Cited by 1,175
Arteriovenous malformations of the brain: natural history in unoperated patients.
Crawford, P. M., West, C. R., Chadwick, D. W., & Shaw, M. D. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.1.1 · Cited by 815
Bleeding from cerebral arteriovenous malformations as part of their natural history
Graf, C. J., Perret, G. E., & Torner, J. C. (1983) · Journal of Neurosurgery · doi:10.3171/jns.1983.58.3.0331 · Cited by 786
Stereotactic radiosurgery for arteriovenous malformations of the brain
Lunsford, L. D., Kondziolka, D., Flickinger, J. C., Bissonette, D. J., Jungreis, C. A., Maitz, A. H., Horton, J. A., & Coffey, R. J. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.4.0512 · Cited by 724
Self-citationBragg-peak proton-beam therapy for arteriovenous malformations of the brain
Kjellberg, R. N., Hanamura, T., Davis, K. R., Lyons, S. L., & Adams, R. D. (1983) · New England Journal of Medicine · doi:10.1056/nejm198308043090503 · Cited by 540
Relationship of perfusion pressure and size to risk of hemorrhage from arteriovenous malformations
Spetzler, R. F., Hargraves, R. W., McCormick, P. W., Zabramski, J. M., Flom, R. A., & Zimmerman, R. S. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.6.0918 · Cited by 454
Drake, C. G. (1979) · Neurosurgery · doi:10.1093/neurosurgery/26.cn_suppl_1.145 · Cited by 450
Arteriovenous malformations of the brain: A long-term clinical study
Forster, D. M. C., Steiner, L., & Håkanson, S. (1972) · Journal of Neurosurgery · doi:10.3171/jns.1972.37.5.0562 · Cited by 433
The Prospective Application of a Grading System for Arteriovenous Malformations
Hamilton, M. G., & Spetzler, R. F. (1994) · Neurosurgery · doi:10.1227/00006123-199401000-00002 · Cited by 389
Linear accelerator radiosurgery for arteriovenous malformations: the relationship of size to outcome
Friedman, W. A., Bova, F. J., & Mendenhall, W. M. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.82.2.0180 · Cited by 327
Steinberg, G. K., Fabrikant, J. I., Marks, M. P., Levy, R. P., Frankel, K. A., Phillips, M. H., Shuer, L. M., & Silverberg, G. D. (1990) · New England Journal of Medicine · doi:10.1056/nejm199007123230205 · Cited by 295
Operative Neurosurgical Techniques: Indications, Methods, and Results
Schmidek, H. H. (1995) · Medical Entomology and Zoology · Cited by 289
An integrated logistic formula for prediction of complications from radiosurgery
Flickinger, J. C. (1989) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(89)90082-5 · Cited by 286
Self-citationHemorrhage in intracerebral arteriovenous malformations: angiographic determinants.
Marks, M. P., Lane, B., Steinberg, G. K., & Chang, P. J. (1990) · Radiology · doi:10.1148/radiology.176.3.2389040 · Cited by 286
Kader, A., Young, W. L., Pile-Spellman, J., Mast, H., Sciacca, R. R., Mohr, J. P., Stein, B. M., & The Columbia University AVM Study Project (1994) · Neurosurgery · doi:10.1097/00006123-199405000-00003 · Cited by 283
Linear accelerator radiosurgery for arteriovenous malformations
Friedman, W. A., & Bova, F. J. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.6.0832 · Cited by 222
Microsurgery for 67 intracranial arteriovenous malformations less than 3 cm in diameter
Sisti, M. B., Kader, A., & Stein, B. M. (1993) · Journal of Neurosurgery · doi:10.3171/jns.1993.79.5.0653 · Cited by 175
Patient Outcomes after Stereotactic Radiosurgery for “Operable” Arteriovenous Malformations
Robinson, J. R., Brown, A. P., & Spetzler, R. F. (1995) · Neurosurgery · doi:10.1227/00006123-199502000-00032 · Cited by 161
Operative Neurosurgical Techniques: Indications, Methods and Results
Erickson, D. L. (1989) · JAMA · doi:10.1001/jama.1989.03420090112046 · Cited by 106
Kondziolka, D. S., Nixon, B. J., Lasjaunias, P. L., Lasjaunias, P. L., Tucker, W. S., terBrugge, K. G., & Spiegel, S. M. (1988) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100027487 · Cited by 71
Self-citationLo, E. H. (1993) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(93)90247-s · Cited by 24
Cited by
International guidelines for the diagnosis and management of hereditary haemorrhagic telangiectasia
Faughnan, M. E., Palda, V. A., Garcia-Tsao, G., Geisthoff, U. W., McDonald, J., Proctor, D. D., Spears, J., Brown, D. H., Buscarini, E., Chesnutt, M. S., et al. (2011) · Journal of Medical Genetics · doi:10.1136/jmg.2009.069013 · Cited by 1,082
Ogilvy, C. S., Stieg, P. E., Awad, I., Brown, R. D., Kondziolka, D., Rosenwasser, R., Young, W. L., & Hademenos, G. (2001) · Stroke · doi:10.1161/01.str.32.6.1458 · Cited by 588
Self-citationFaughnan, M. E., Mager, J. J., Hetts, S. W., Palda, V. A., Lang-Robertson, K., Buscarini, E., Deslandres, E., Kasthuri, R. S., Lausman, A., Poetker, D., et al. (2020) · Annals of Internal Medicine · doi:10.7326/m20-1443 · Cited by 537
Fleetwood, I. G., & Steinberg, G. K. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07946-1 · Cited by 383
Factors Associated with Successful Arteriovenous Malformation Radiosurgery
Pollock, B. E., Flickinger, J. C., Lunsford, L. D., Maitz, A., & Kondziolka, D. (1998) · Neurosurgery · doi:10.1097/00006123-199806000-00020 · Cited by 379
Self-citation
Metadata
- Authors
- Pollock, B. E., Flickinger, J. C., Lunsford, L. D., Bissonette, D. J., & Kondziolka, D.
- Venue
- Neurosurgery
- Published
- 1996-04
- Volume
- 38
- Issue
- 4
- Pages
- 652-661
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2002199411
- Cited by
- 315
- References
- 27
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.