Measurement of Intraoperative Brain Surface Deformation under a Craniotomy
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Several causes of spatial inaccuracies in image-guided surgery have been carefully studied and documented for several systems. These include error in identifying the external features used for registration, geometrical distortion in the preoperative images, and error in tracking the surgical instruments. Another potentially important source of error is brain deformation between the time of imaging and the time of surgery or during surgery. In this study, we measured the deformation of the dura and brain surfaces between the time of imaging and the start of surgical resection for 21 patients. METHODS: All patients underwent intraoperative functional mapping, allowing us to measure brain surface motion at two times that were separated by nearly an hour after opening the dura but before performing resection. The positions of the dura and brain surfaces were recorded and transformed to the coordinate space of a preoperative magnetic resonance image, using the Acustar surgical navigation system (manufactured by Johnson & Johnson Professional, Inc., Randolph, MA) (the Acustar trademark and associated intellectual property rights are now owned by Picker International, Highland Heights, OH). This system performs image registration with bone-implanted markers and tracks a surgical probe by optical triangulation. RESULTS: The mean displacements of the dura and the first and second brain surfaces were 1.2, 4.4, and 5.6 mm, respectively, with corresponding mean volume reductions under the craniotomy of 6, 22, and 29 cc. The maximum displacement was greater than 10 mm in approximately one-third of the patients for the first brain surface measurement and one-half of the patients for the second. In all cases, the direction of brain shift corresponded to a "sinking" of the brain intraoperatively, compared with its preoperative position. Analysis of the measurement error revealed that its magnitude was approximately 1 to 2 mm. We observed two different patterns of the brain surface deformation field, depending on the inclination of the craniotomy with respect to gravity. Separate measurements of brain deformation within the closed cranium caused by changes in patient head orientation with respect to gravity suggested that less than 1 mm of the brain shift recorded intraoperatively could have resulted from the change in patient orientation between the time of imaging and the time of surgery. CONCLUSION: These results suggest that intraoperative brain deformation is an important source of error that needs to be considered when using surgical navigation systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationStudholme, C., Hill, D. L. G., & Hawkes, D. J. (1997) · Medical Physics · doi:10.1118/1.598130 · Cited by 675
Self-citationA frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
Roberts, D. W., Strohbehn, J. W., Hatch, J. F., Murray, W. T., & Kettenberger, H. (1986) · Journal of neurosurgery · doi:10.3171/jns.1986.65.4.0545 · Cited by 640
Registration of head volume images using implantable fiducial markers
Maurer, C. R., Fitzpatrick, J. M., Wang, M. Y., Galloway, R. L., Maciunas, R. J., & Allen, G. S. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.611354 · Cited by 561
Self-citationJack, C. R., Thompson, R. M., Butts, R. K., Sharbrough, F. W., Kelly, P. J., Hanson, D. P., Riederer, S. J., Ehman, R. L., Hangiandreou, N. J., & Cascino, G. D. (1994) · Radiology · doi:10.1148/radiology.190.1.8259434 · Cited by 375
Conversion of complex contour line definitions into polygonal element mosaics
Christiansen, H. N., & Sederberg, T. W. (1978) · Proceedings of the 5th annual conference on Computer graphics and interactive techniques · doi:10.1145/800248.807388 · Cited by 317
Puce, A., Constable, R. T., Luby, M. L., McCarthy, G., Nobre, A. C., Spencer, D. D., Gore, J. C., & Allison, T. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.2.0262 · Cited by 312
Brain parenchyma motion: measurement with cine echo-planar MR imaging.
Poncelet, B. P., Wedeen, V. J., Weisskoff, R. M., & Cohen, M. S. (1992) · Radiology · doi:10.1148/radiology.185.3.1438740 · Cited by 285
Comparison and evaluation of retrospective intermodality image registration techniques:
West, J. B., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, Jr., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A. M. F., et al. (1996) · SPIE Proceedings · doi:10.1117/12.237936 · Cited by 269
Self-citationComputer-assisted stereotaxic laser resection of intra-axial brain neoplasms
Kelly, P. J., Kall, B. A., Goerss, S., & Earnest, F. (1986) · Journal of Neurosurgery · doi:10.3171/jns.1986.64.3.0427 · Cited by 267
A physics-based coordinate transformation for 3-D image matching
Davis, M. H., Khotanzad, A., Flamig, D. P., & Harms, S. E. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585766 · Cited by 266
Conversion of complex contour line definitions into polygonal element mosaics
Christiansen, H. N., & Sederberg, T. W. (1978) · ACM SIGGRAPH Computer Graphics · doi:10.1145/965139.807388 · Cited by 231
Interactive image-guided neurosurgery
Galloway, R. L., Maciunas, R. J., & Edwards, C. A. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.184698 · Cited by 229
Self-citationInteractive Image‐Guided Neurosurgery
(1995) · Journal of Neuroimaging · doi:10.1111/jon19955154b · Cited by 203
BRAIN WATER MEASURED BY MAGNETIC RESONANCE IMAGING
Bell, B. A., Kean, D. M., MacDonald, H. L., Barnett, G. H., Douglas, R. H. B., Smith, M. A., McGhee, C. N. J., Miller, J. D., Tocher, J. L., & Best, J. J. K. (1987) · The Lancet · doi:10.1016/s0140-6736(87)91908-8 · Cited by 154
Registration of 3-D images using weighted geometrical features
Maurer, C. R., Aboutanos, G. B., Dawant, B. M., Maciunas, R. J., & Fitzpatrick, J. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.544501 · Cited by 154
Self-citationAdams, L., Krybus, W., Meyer‐Ebrecht, D., Rueger, R., Gilsbach, J. M., Moesges, R., & Schlöndorff, G. (1990) · IEEE Computer Graphics and Applications · doi:10.1109/38.55152 · Cited by 138
An articulated neurosurgical navigation system using MRI and CT images
Kosugi, Y., Watanabe, E., Goto, J.-I., Watanabe, T., Yoshimoto, S., Takakura, K., & Ikebe, J. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1353 · Cited by 126
Colchester, A. C. F., Zhao, J. C., Tainter, K. S. H., Henri, C. J., Maitland, N., Roberts, P. T. E., Harris, C. G., & Evans, R. (1996) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80006-2 · Cited by 90
A three-component deformation model for image-guided surgery
Edwards, P., Hill, D., Little, J. A., & Hawkes, D. J. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80016-9 · Cited by 77
Self-citationVolume regulation of the brain tissue?a survey
D�czi, T. (1993) · Acta Neurochirurgica · doi:10.1007/bf01405174 · Cited by 73
Cited by
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Intraoperative brain cancer detection with Raman spectroscopy in humans
Jermyn, M., Mok, K., Mercier, J., Desroches, J., Pichette, J., Saint-Arnaud, K., Bernstein, L., Guiot, M.-C., Petrecca, K., & Leblond, F. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2384 · Cited by 618
Duffau, H., Capelle, L., Denvil, D., Sichez, N., Gatignol, P., Taillandier, L., Lopes, M., Mitchell, M.-C., Roche, S., Muller, J.-C., et al. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0764 · Cited by 539
Serial Intraoperative Magnetic Resonance Imaging of Brain Shift
Nabavi, A., Black, P. M., Gering, D. T., Westin, C.-F., Mehta, V., Pergolizzi, R. S., Ferrant, M., Warfield, S. K., Hata, N., Schwartz, R. B., et al. (2001) · Neurosurgery · doi:10.1097/00006123-200104000-00019 · Cited by 461
Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical model
Ferrant, M., Nabavi, A., Macq, B., Jolesz, F. A., Kikinis, R., & Warfield, S. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.974933 · Cited by 339
Metadata
- Authors
- Hill, D. L. G., Maurer, C. R., Maciunas, R. J., Maciunas, R. J., Barwise, J. A., Fitzpatrick, J. M., & Wang, M. Y.
- Venue
- Neurosurgery
- Published
- 1998-09
- Volume
- 43
- Issue
- 3
- Pages
- 514-526
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W1484665822
- Cited by
- 404
- References
- 22
- FWCI
- 42.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.