Image-guided Robotic Radiosurgery
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: To describe the design and performance of a novel frameless system for radiosurgery. This technology, called image-guided radiosurgery (IGR), eliminates the need for stereotactic frame fixation by relating the identified lesion to radiographic landmarks. CONCEPT: IGR uses a lightweight x-band linear accelerator, computer-controlled robotic arm (Fanuc manipulator [Fanuc Robotics North America, Inc., Rochester Hills, MI]), paired orthogonal x-ray imagers, and a computer workstation that performs rapid image-to-image registration. During radiosurgery, the x-ray imaging system determines the location of the lesion and communicates these coordinates to the robot, which adjusts the pointing of the linear accelerator beam to maintain alignment with the target. RATIONALE: Existing stereotactic techniques require rigid cranial fixation to establish and maintain a system of reference for targeting. Such frames cause pain for the patient, limit the use of fractionation, and necessitate a prolonged period of general anesthesia if children are to be treated. Furthermore, skeletal or any other type of rigid fixation is difficult to achieve beyond the cranium. IGR was designed to overcome these limitations, which are inherent to nearly all current radiosurgical methods. DISCUSSION: Preliminary testing and early clinical experience have demonstrated the practicality and potential of the IGR concept and have identified the most important directions for improvement. For example, an IGR prototype accurately tracked target displacements in three dimensions but showed reduced accuracy when confronted by rotational movements. This observation led to development of a new generation of tracking algorithm that promises to improve tracking in all six dimensions. Further experience indicated that improvements in the quality of the x-ray images were needed to allow the system to locate and treat target sites outside the cranium. Consequently, a new x-ray imaging technology with superior resolution and increased sensitivity has been added to the system. These improvements should make it possible to apply IGR techniques to a variety of targets located throughout the body. This article describes and critiques the components of the IGR and summarizes our preliminary clinical experience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Application Accuracy of Stereotactic Frames
Maciunas, R. J., Galloway, R. L., & Latimer, J. W. (1994) · Neurosurgery · doi:10.1227/00006123-199410000-00015 · Cited by 395
Adaptation and verification of the relocatable gill-thomas-cosman frame in stereotactic radiotherapy
Kooy, H. M., Dunbar, S. F., Tarbell, N. J., Mannarino, E., Ferarro, N., Shusterman, S., Bellerive, M., Finn, L., McDonough, C. V., & Loeffler, J. S. (1994) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(92)90956-i · Cited by 197
Murphy, M. J. (1997) · Medical Physics · doi:10.1118/1.598005 · Cited by 171
Self-citationA real-time, flat-panel, amorphous silicon, digital x-ray imager.
Antonuk, L. E., Yorkston, J., Huang, W., Siewerdsen, J. H., Boudry, J. M., El‐Mohri, Y., & Marx, M. V. (1995) · Radiographics · doi:10.1148/radiographics.15.4.7569143 · Cited by 87
Voxel‐based localization in frame‐based and frameless stereotaxy and its accuracy
Lemieux, L., Kitchen, N. D., Hughes, S., & Thomas, D. G. T. (1994) · Medical Physics · doi:10.1118/1.597403 · Cited by 66
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Heavy-ion tumor therapy: Physical and radiobiological benefits
Schardt, D., Elsässer, T., & Schulz-Ertner, D. (2010) · Reviews of Modern Physics · doi:10.1103/revmodphys.82.383 · Cited by 778
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…3D/2D image registration are radiotherapy and radiosurgery, where as a result of the research efforts two commercial systems, Accuray Cyberknife (Adler et al., 1999; Fu and Kuduvalli, 2008b; Fu and 14 Benameur et al. (2005b), Birkfellner et al. (2003), Byrne et al. (2004), Chen et al. (2008),…”
BackgroundMethodInfluentialRobotic motion compensation for respiratory movement during radiosurgery
Schweikard, A., Glosser, G., Bodduluri, M., Murphy, M. J., & Adler, J. R. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:4<263::aid-igs5>3.0.co;2-2 · Cited by 393
Self-citationPrediction of respiratory tumour motion for real-time image-guided radiotherapy
Sharp, G. C., Jiang, S. B., Shimizu, S., & Shirato, H. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/006 · Cited by 355
Image-guided Hypo-fractionated Stereotactic Radiosurgery to Spinal Lesions
Ryu, S. I., Chang, S. D., Kim, D. H., Murphy, M. J., Le, Q.-T., Martin, D. P., & Adler, J. R. (2001) · Neurosurgery · doi:10.1097/00006123-200110000-00011 · Cited by 344
Self-citationAn Analysis of the Accuracy of the CyberKnife: A Robotic Frameless Stereotactic Radiosurgical System
(2003) · Neurosurgery · doi:10.1227/0006123-200301000-00018 · Cited by 299
Kassahun, Y., Yu, B., Tibebu, A. T., Stoyanov, D., Giannarou, S., Metzen, J. H., & Vander Poorten, E. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1305-z · Cited by 238
State of the art in surgical robotics: Clinical applications and technology challenges
Cleary, K., & Nguyen, C. (2001) · Computer Aided Surgery · doi:10.1002/igs.10019 · Cited by 238
“Orthopedic USA Integrated Surgical ROBODOC Human [11] Orthopedic USA Georgetown/Hopkins PAKY/RCM Cadaver [16, 17] Orthopedic USA Univ of Tokyo/Hopkins PAKY/RCM Phantom This issue Orthopedic USA Marconi Kawasaki Pig This issue Orthopedic UK Imperial College Acrobot Human This issue Urology UK Imperial College Probot Hu…”
BackgroundIn Touch with Robotics: Neurosurgery for the Future
Nathoo, N., Çavuşoğlu, M. C., Vogelbaum, M. A., & Barnett, G. H. (2005) · Neurosurgery · doi:10.1227/01.neu.0000153929.68024.cf · Cited by 221
“(1) described an innovative approach to radiosurgery.”
A Perspective on Medical Robotics
Taylor, R. H. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.880669 · Cited by 220
Heron, D. E., Ferris, R. L., Karamouzis, M., Andrade, R. S., Deeb, E. L., Burton, S., Gooding, W. E., Branstetter, B. F., Mountz, J. M., Johnson, J. T., et al. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.12.075 · Cited by 179
Robot-assisted procedures in pediatric neurosurgery
De Benedictis, A., Trezza, A., Carai, A., Genovese, E., Procaccini, E., Messina, R., Randi, F., Cossu, S., Esposito, G., Palma, P., et al. (2017) · Neurosurgical Focus · doi:10.3171/2017.2.focus16579 · Cited by 178
Li, Q. H., Zamorano, L., Pandya, A. D., Perez, R., Gong, J., & Diaz, F. (2002) · Computer Aided Surgery · doi:10.1002/igs.10035 · Cited by 178
Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT
Livyatan, H., Yaniv, Z., & Joskowicz, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819288 · Cited by 176
“for radiosurgery [7], among many others.”
BackgroundMethodInfluentialA STUDY OF THE ACCURACY OF CYBERKNIFE SPINAL RADIOSURGERY USING SKELETAL STRUCTURE TRACKING
Ho, A. K., Fu, D., Cotrutz, C., Hancock, S. L., Chang, S. D., Gibbs, I. C., Maurer, C. R., & Adler, J. R. (2007) · Operative Neurosurgery · doi:10.1227/01.neu.0000249248.55923.ec · Cited by 163
“The CyberKnife radiosurgery system has been described previously in detail (1, 6).”
MethodSelf-citationRussakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
Self-citationIntraoperative 2D/3D Image Registration via Differentiable X-Ray Rendering
Gopalakrishnan, V., Dey, N., & Golland, P. (2024) · 2024 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52733.2024.01108 · Cited by 87
“Beyond localization of instruments relative to patient anatomy, accurate 2D/3D rigid registration is critical to cutting-edge surgical innovations incorporating robotic assistance and augmented reality [2, 3, 20].”
BackgroundEffective Intensity-Based 2D/3D Rigid Registration between Fluoroscopic X-Ray and CT
Knaan, D., & Joskowicz, L. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39899-8_44 · Cited by 43
“To date, the Cyberknife [ 4 ] is the only system in clinical use based on intensity-based registration [9].”
BackgroundEvaluation of Intensity-Based 2D-3D Spine Image Registration Using Clinical Gold-Standard Data
Russakoff, D. B., Rohlfing, T., Ho, A., Kim, D. H., Shahidi, R., Adler, J. R., & Maurer, C. R. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39701-4_16 · Cited by 43
Self-citation
Metadata
- Authors
- Adler, J. R., Murphy, M. J., Chang, S. D., & Hancock, S. L.
- Venue
- Neurosurgery
- Published
- 1999-06
- Volume
- 44
- Issue
- 6
- Pages
- 1299-1306
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2075060606
- Cited by
- 412
- References
- 5
- FWCI
- 9.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.