Long-term Hardware-related Complications of Deep Brain Stimulation
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the incidence of long-term hardware-related complications of deep brain stimulation (DBS). METHODS: The study design is a retrospective chart review of a single-surgeon, single-institution experience with DBS in 84 consecutive cases from 1993 to 1999. Only patients with a minimum follow-up of 1 year were considered. Five patients were excluded because trial stimulation failed to achieve pain relief (n = 4) or because the procedure was aborted owing to hemorrhage (n = 1). Seventy-nine patients received 124 permanent DBS electrode implants. RESULTS: The mean follow-up period was 33 months, and the cumulative follow-up time was 217 patient-years or 310 electrode-years. Overall, 20 patients (25.3%) had 26 hardware-related complications involving 23 (18.5%) of the electrodes. There were 4 lead fractures, 4 lead migrations, 3 short or open circuits, 12 erosions and/or infections, 2 foreign body reactions, and one cerebrospinal fluid leak. The hardware-related complication rate per electrode-year was 8.4%. The most common complications were related to the electrode connectors. A significant finding was a high number of complications involving erosions or infections, which occurred in 7 of 12 instances as a late complication (beyond 12 mo). CONCLUSION: Long-term follow-up reveals that hardware-related complications occur in a significant number of patients. Factors that lead to such complications must be identified and addressed to maximize the important benefits of DBS therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Comparison of Continuous Thalamic Stimulation and Thalamotomy for Suppression of Severe Tremor
Schuurman, P. R., Bosch, D. A., Bossuyt, P. M. M., Bonsel, G. J., van Someren, E. J. W., de Bie, R. M. A., Merkus, M. P., & Speelman, J. D. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420703 · Cited by 1,044
Atlas for stereotaxy of the human brain
Bosch, D. A. (1978) · Clinical Neurology and Neurosurgery · doi:10.1016/s0303-8467(78)80027-4 · Cited by 867
Multicentre European study of thalamic stimulation in parkinsonian and essential tremor
Limousin, P., Speelman, J. D., Gielen, F., Janssens, M., & collaborators, S. (1999) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.66.3.289 · Cited by 491
High‐frequency unilateral thalamic stimulation in the treatment of essential and parkinsonian tremor
Koller, W., Pahwa, R., Busenbark, K., Hubble, J., Wilkinson, S., Lang, A., Tuite, P., Sime, E., Lazano, A., Hauser, R., et al. (1997) · Annals of Neurology · doi:10.1002/ana.410420304 · Cited by 478
Self-citationDeep Brain Stimulation for Intractable Pain: A 15-Year Experience
Kumar, K., Toth, C., & Nath, R. K. (1997) · Neurosurgery · doi:10.1097/00006123-199704000-00015 · Cited by 387
Long-Term Electrical Inhibition of Deep Brain Targets in Movement Disorders
Benabid, A. L., Benazzouz, A., Hoffmann, D., Limousin, P., Krack, P., & Pollak, P. (2008) · Movement Disorders · doi:10.1002/mds.870131321 · Cited by 375
Levy, R. M., Lamb, S., & Adams, J. E. (1987) · Neurosurgery · doi:10.1227/00006123-198712000-00017 · Cited by 319
Rezai, A. R., Lozano, A. M., Crawley, A. P., Joy, M. L. G., Davis, K. D., Kwan, C. L., Dostrovsky, J. O., Tasker, R. R., & Mikulis, D. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.3.0583 · Cited by 169
Self-citationTextbook of Stereotactic and Functional Neurosurgery
Staal, M. J. (1999) · Spinal Cord · doi:10.1038/sj.sc.3100743 · Cited by 136
Deep Brain Stimulator Electrodes Used for Lesioning: Proof of Principle
Oh, M. Y., Hodaie, M., Kim, S. H., Alkhani, A. M., Lang, A. E., & Lozano, A. M. (2001) · Neurosurgery · doi:10.1097/00006123-200108000-00018 · Cited by 61
Self-citation
Cited by
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Deep brain stimulation of the subthalamic nucleus for the treatment of Parkinson's disease
Benabid, A. L., Chabardes, S., Mitrofanis, J., & Pollak, P. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70291-6 · Cited by 1,285
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Samii, A., Nutt, J. G., & Ransom, B. R. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16305-8 · Cited by 1,265
Kaplitt, M. G., Feigin, A., Tang, C., Fitzsimons, H. L., Mattis, P., Lawlor, P. A., Bland, R. J., Young, D., Strybing, K., Eidelberg, D., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60982-9 · Cited by 1,067
Bilateral deep brain stimulation in Parkinson's disease: a multicentre study with 4 years follow-up
Rodriguez-Oroz, M. C., Obeso, J. A., Lang, A. E., Houeto, J.-L., Pollak, P., Rehncrona, S., Kulisevsky, J., Albanese, A., Volkmann, J., Hariz, M. I., et al. (2005) · Brain · doi:10.1093/brain/awh571 · Cited by 1,057
Self-citationPahwa, R., Factor, S. A., Lyons, K. E., Ondo, W. G., Gronseth, G., Bronte-Stewart, H., Hallett, M., Miyasaki, J., Stevens, J., & Weiner, W. J. (2006) · Neurology · doi:10.1212/01.wnl.0000215250.82576.87 · Cited by 499
Fenoy, A. J., & Simpson, R. K. (2014) · Journal of Neurosurgery · doi:10.3171/2013.10.jns131225 · Cited by 449
Treatment of motor and non-motor features of Parkinson's disease with deep brain stimulation
Fasano, A., Daniele, A., & Albanese, A. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70049-2 · Cited by 437
Vidailhet, M., Vercueil, L., Houeto, J.-L., Krystkowiak, P., Lagrange, C., Yelnik, J., Bardinet, E., Benabid, A.-L., Navarro, S., Dormont, D., et al. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70035-2 · Cited by 437
The functional role of the subthalamic nucleus in cognitive and limbic circuits
Temel, Y., Blokland, A., Steinbusch, H. W. M., & Visser-Vandewalle, V. (2005) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2005.09.005 · Cited by 426
Temel, Y., Kessels, A., Tan, S., Topdag, A., Boon, P., & Visser-Vandewalle, V. (2006) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2006.01.004 · Cited by 424
Electrical brain stimulation for epilepsy
Fisher, R. S., & Velasco, A. L. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.59 · Cited by 402
Advances in the treatment of Parkinson's disease
Singh, N., Pillay, V., & Choonara, Y. E. (2007) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2006.11.009 · Cited by 394
Velasco, A. L., Velasco, F., Velasco, M., Trejo, D., Castro, G., & Carrillo‐Ruiz, J. D. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01181.x · Cited by 331
Deep brain stimulation: Postoperative issues
Deuschl, G., Herzog, J., Kleiner-Fisman, G., Kubu, C., Lozano, A. M., Lyons, K. E., Rodriguez-Oroz, M. C., Tamma, F., Tröster, A. I., Vitek, J. L., et al. (2006) · Movement Disorders · doi:10.1002/mds.20957 · Cited by 313
Self-citationDeep brain stimulation for drug‐resistant epilepsy
Li, M. C. H., & Cook, M. J. (2018) · Epilepsia · doi:10.1111/epi.13964 · Cited by 293
Review: Deep brain stimulation in Parkinson’s disease
Groiss, S. J., Wojtecki, L., Südmeyer, M., & Schnitzler, A. (2009) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756285609339382 · Cited by 280
Suchowersky, O., Reich, S., Perlmutter, J., Zesiewicz, T., Gronseth, G., & Weiner, W. J. (2006) · Neurology · doi:10.1212/01.wnl.0000215437.80053.d0 · Cited by 280
Hamani, C., Richter, E., Schwalb, J. M., & Lozano, A. M. (2005) · Neurosurgery · doi:10.1227/01.neu.0000159714.28232.c4 · Cited by 280
Self-citationDeep brain stimulation for movement disorders: morbidity and mortality in 109 patients
Umemura, A., Jaggi, J. L., Hurtig, H. I., Siderowf, A. D., Colcher, A., Stern, M. B., & Baltuch, G. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0779 · Cited by 279
Breit, S., Schulz, J. B., & Benabid, A.-L. (2004) · Cell and Tissue Research · doi:10.1007/s00441-004-0936-0 · Cited by 273
Voges, J. (2006) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.081232 · Cited by 273
Surgical and hardware complications of subthalamic stimulation: A series of 160 procedures
Lyons, K. E., Wilkinson, S. B., Overman, J., & Pahwa, R. (2004) · Neurology · doi:10.1212/01.wnl.0000134650.91974.1a · Cited by 271
The RNS System: responsive cortical stimulation for the treatment of refractory partial epilepsy
Sun, F. T., & Morrell, M. J. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.947274 · Cited by 266
DEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONS: INCIDENCE AND MANAGEMENT IN A LARGE SERIES
Sillay, K. A., Larson, P. S., & Starr, P. A. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316002.03765.33 · Cited by 225
Stefurak, T., Mikulis, D., Mayberg, H., Lang, A. E., Hevenor, S., Pahapill, P., Saint‐Cyr, J., & Lozano, A. (2003) · Movement Disorders · doi:10.1002/mds.10593 · Cited by 215
Self-citationThalamic deep brain stimulation in the treatment of essential tremor: a long-term follow-up
Blomstedt, P., Hariz, G.-M., Hariz, M. I., & Koskinen, L.-O. D. (2007) · British Journal of Neurosurgery · doi:10.1080/02688690701552278 · Cited by 207
de Koning, P. P., Figee, M., van den Munckhof, P., Schuurman, P. R., & Denys, D. (2011) · Current Psychiatry Reports · doi:10.1007/s11920-011-0200-8 · Cited by 202
“Lead breakage and failure of the neurostimulator, reported to occur in as many as 8% of cases in 2002 [28], have rarely been noted in more recent literature.”
BackgroundDeep Brain Stimulation for Primary Generalized Dystonia: Long-term Outcomes
Isaias, I. U., Alterman, R. L., & Tagliati, M. (2009) · Archives of Neurology · doi:10.1001/archneurol.2009.20 · Cited by 198
“All hardware-related adverse events were identified, and their incidence was calculated in electrodeyears, defined as the number of years with an electrode implanted.(14,15)”
BackgroundBoviatsis, E. J., Stavrinou, L. C., Themistocleous, M., Kouyialis, A. T., & Sakas, D. E. (2010) · Acta Neurochirurgica · doi:10.1007/s00701-010-0749-8 · Cited by 192
“Our literature review reveals a mean rate of 5% per patient and 1.8% per procedure for postoperative electrode breakage [7, 9, 13, 17, 26, 29, 35, 38 , 51, 54].”
BackgroundInfluentialLong-term results of thalamic deep brain stimulation for essential tremor: Clinical article
Zhang, K., Bhatia, S., Oh, M. Y., Cohen, D., Angle, C., & Whiting, D. (2010) · Journal of Neurosurgery · doi:10.3171/2009.10.jns09371 · Cited by 190
Self-citationAn update on best practice of deep brain stimulation in Parkinson’s disease
Hartmann, C. J., Fliegen, S., Groiss, S. J., Wojtecki, L., & Schnitzler, A. (2019) · Therapeutic Advances in Neurological Disorders · doi:10.1177/1756286419838096 · Cited by 173
Bullard, A. J., Hutchison, B. C., Lee, J., Chestek, C. A., & Patil, P. G. (2020) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.13069 · Cited by 65
The safety of Micro-implants for the brain
Dabbour, A.-H., Tan, S., Kim, S. H., Guild, S.-J., Heppner, P., McCormick, D., Wright, B. E., Leung, D., Gallichan, R., Budgett, D., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.796203 · Cited by 13
Self-citation
Metadata
- Authors
- Oh, M. Y., Abosch, A., Kim, S. H., Lang, A. E., & Lozano, A. M.
- Venue
- Neurosurgery
- Published
- 2002-06-01
- Volume
- 50
- Issue
- 6
- Pages
- 1268-1276
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2017863178
- Cited by
- 405
- References
- 11
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.