An Alternative to the Classical Nerve Graft for the Management of the Short Nerve Gap
The DOI matches its Crossref record.
Abstract
Reconstruction of a short nerve gap by a nerve graft produces donor-site scarring, loss of donor nerve function, and neuroma formation. This study compared the regeneration achieved after 1 year in 16 monkeys across a 3-cm upper arm ulnar nerve gap with a bioabsorbable polyglycolic acid nerve conduit with the regeneration achieved with a classical interfascicular interpositional sural nerve graft. The results demonstrated electrophysiologic and histologic evidence of neural regeneration across the gaps in all experimental groups. The bioabsorbable nerve conduit groups and the sural nerve graft group had mean fiber diameters, amplitudes, and conduction velocities each significantly less than those of normal control ulnar nerves. There was, however, no significant difference between any of the experimental groups. Electromyography demonstrated recovery of 19 of the 28 (68 percent) intrinsic muscles studied. These results demonstrate that the primate peripheral nerve can regenerate across short nerve gaps when guided by an appropriate nerve conduit, suggesting that a single-stage biodegradable polyglycolic acid conduit may be used as an alternative to a short interfascicular nerve graft.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kehoe, S., Zhang, X. F., & Boyd, D. (2012) · Injury · doi:10.1016/j.injury.2010.12.030 · Cited by 725
Lundborg, G. (2000) · The Journal of Hand Surgery · doi:10.1053/jhsu.2000.4165 · Cited by 656
Neural tissue engineering options for peripheral nerve regeneration
Gu, X., Ding, F., & Williams, D. F. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.04.064 · Cited by 630
“[45,88,89], centrifugal casting [90], spinning mandrel technology [91], film casting plus rolling [92,93], and molding plus freeze-”
MethodGu, X., Ding, F., Yang, Y., & Liu, J. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.11.002 · Cited by 583
Weber, R. A., Breidenbach, W. C., Brown, R. E., Jabaley, M. E., & Mass, D. P. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200010000-00013 · Cited by 552
Peripheral nerve regeneration through guidance tubes
Belkas, J. S., Shoichet, M. S., & Midha, R. (2004) · Neurological Research · doi:10.1179/016164104225013798 · Cited by 415
Biomaterials for the Development of Peripheral Nerve Guidance Conduits
Nectow, A. R., Marra, K. G., & Kaplan, D. L. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0240 · Cited by 395
Matsumoto, K., Ohnishi, K., Kiyotani, T., Sekine, T., Ueda, H., Nakamura, T., Endo, K., & Shimizu, Y. (2000) · Brain Research · doi:10.1016/s0006-8993(00)02207-1 · Cited by 370
Controlled release of nerve growth factor enhances sciatic nerve regeneration
Lee, A. C., Yu, V. M., Lowe, J. B., Brenner, M. J., Hunter, D. A., Mackinnon, S. E., & Sakiyama-Elbert, S. E. (2003) · Experimental Neurology · doi:10.1016/s0014-4886(03)00258-9 · Cited by 369
Self-citationMonkey median nerve repaired by nerve graft or collagen nerve guide tube
Archibald, S., Shefner, J., Krarup, C., & Madison, R. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-05-04109.1995 · Cited by 359
Designing ideal conduits for peripheral nerve repair
de Ruiter, G. C. W., Malessy, M. J. A., Yaszemski, M. J., Windebank, A. J., & Spinner, R. J. (2009) · Neurosurgical Focus · doi:10.3171/foc.2009.26.2.e5 · Cited by 352
Battiston, B., Geuna, S., Ferrero, M., & Tos, P. (2005) · Microsurgery · doi:10.1002/micr.20127 · Cited by 346
Complications from silicon‐polymer intubulation of nerves
Merle, M., Lee Dellon, A., Campbell, J. N., & Chang, P. S. (1989) · Microsurgery · doi:10.1002/micr.1920100213 · Cited by 298
Ceballos, D., Navarro, X., Dubey, N., Wendelschafer-Crabb, G., Kennedy, W. R., & Tranquillo, R. T. (1999) · Experimental Neurology · doi:10.1006/exnr.1999.7111 · Cited by 291
Nerve Repair by Means of Tubulization: Past, Present, Future
Konofaos, P., & Ver Halen, J. (2013) · Journal of Reconstructive Microsurgery · doi:10.1055/s-0032-1333316 · Cited by 269
Limitations of Conduits in Peripheral Nerve Repairs
Moore, A. M., Kasukurthi, R., Magill, C. K., Farhadi, H. F., Borschel, G. H., & Mackinnon, S. E. (2009) · HAND · doi:10.1007/s11552-008-9158-3 · Cited by 268
Self-citationIchihara, S., Inada, Y., & Nakamura, T. (2008) · Injury · doi:10.1016/j.injury.2008.08.029 · Cited by 222
Gaudin, R., Knipfer, C., Henningsen, A., Smeets, R., Heiland, M., & Hadlock, T. (2016) · BioMed Research International · doi:10.1155/2016/3856262 · Cited by 207
“Dellon and Mackinnon demonstrated positive results after 1 year in a 3 cm ulnar nerve gap in monkeys using a second-generation nerve conduit compared to autografts [71].”
BackgroundKrekoski, C. A., Neubauer, D., Zuo, J., & Muir, D. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-16-06206.2001 · Cited by 179
“Neuroma formation is often associated with regeneration failure after nerve injury and surgical repair (Dellon and Mackinnon, 1988).”
BackgroundKrarup, C., Archibald, S. J., & Madison, R. D. (2002) · Annals of Neurology · doi:10.1002/ana.10054 · Cited by 172
Metadata
- Authors
- Dellon, A. L., & Mackinnon, S. E.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1988-11
- Volume
- 82
- Issue
- 5
- Pages
- 849-856
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2027862144
- Cited by
- 292
- References
- 0
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.