Training the Generation X Plastic Surgeon: Dispelling the Myths?
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
An increasing number of injectable filler materials for facial wrinkles and folds points to the need for objective measurements of their effectiveness. Patient satisfaction is the goal, but proof of the value of a particular product requires objective measurement. A wrinkle assessment scale was developed as a simple tool for use by plastic surgeons, dermatologists, and aesthetic surgeons who want to assess the changes resulting from injecting filler materials in their patients. By correlating the grade of the wrinkle in the reference photographs with the wrinkle in a patient's face, a classification of 0 to 5 is assigned. Reliability of the scale was assessed by "live" judgment of 76 wrinkles by nine observers. The same rating was given to 92.7 percent of all wrinkles. In a second trial, photographs from 130 wrinkles were presented to eight observers who rated 89.4 percent of all wrinkles equally. A significant correlation of 87 percent was found between subjective ratings and objective wrinkle depth measured by profilometry on 40 silicone impressions. Manufacturers, monitors of clinical trials, health authorities, and most important, patients will benefit from objective data on current and new injectable materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Body Contouring by Lipolysis: A 5-Year Experience with over 3000 Cases
Illouz, Y.-G., & Illouz, Y.-G. (1983) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-198311000-00001 · Cited by 700
Tumescent Technique for Regional Anesthesia Permits Lidocaine Doses of 35 mg/kg for Liposuction
KLEIN, J. A. (1990) · The Journal of Dermatologic Surgery and Oncology · doi:10.1111/j.1524-4725.1990.tb03961.x · Cited by 672
Pulsed Carbon Dioxide Laser Resurfacing of Photoaged Facial Skin
Fitzpatrick, R. E. (1996) · Archives of Dermatology · doi:10.1001/archderm.132.4.395 · Cited by 640
Tumescent Technique for Local Anesthesia Improves Safety in Large-Volume Liposuction
Klein, J. A. (1993) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199311000-00014 · Cited by 475
Aesthetic and anatomic analysis of the aging skin
Glogau, R. G. (1996) · Seminars in Cutaneous Medicine and Surgery · doi:10.1016/s1085-5629(96)80003-4 · Cited by 296
The anatomy and pathogenesis of wrinkles
KLIGMAN, A. M., ZHENG, P., & LAVKER, R. M. (1985) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1985.tb02042.x · Cited by 197
Olenius, M. (1998) · Aesthetic Plastic Surgery · doi:10.1007/s002669900172 · Cited by 170
Rohrich, R. J., Reagan, B. J., Adams, W. P., Kenkel, J. M., & Beran, S. J. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200001000-00067 · Cited by 168
Self-citationOptical profilometry: An objective method for quantification of facial wrinkles
Grove, G. L., Grove, M. J., & Leyden, J. J. (1989) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(89)70230-9 · Cited by 165
The Role of Subcutaneous Infiltration in Suction-Assisted Lipoplasty: A Review
Rohrich, R. J., Beran, S. J., & Fodòr, P. B. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199702000-00031 · Cited by 157
Self-citationSafety Considerations and Fluid Resuscitation in Liposuction: An Analysis of 53 Consecutive Patients
Trott, S. A., Beran, S. J., Rohrich, R. J., Kenkel, J. M., Adams, W. P., & Klein, K. W. (1998) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199811000-00063 · Cited by 141
Self-citationTumescent Liposuction Complicated by Pulmonary Edema
Gilliland, M. D., & Coates, N. R. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199701000-00032 · Cited by 126
Soft-Tissue Augmentation with Injectable Alginate and Syngeneic Fibroblasts
Marler, J. J., Guha, A., Rowley, J., Koka, R., Mooney, D., Upton, J., & Vacanti, J. P. (2000) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200005000-00020 · Cited by 117
Ultrasound-Assisted Lipoplasty: A Clinical Study of 250 Consecutive Patients
Maxwell, P. G., & Gingrass, M. K. (1998) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199801000-00034 · Cited by 111
Pitman, G. H., Aker, J. S., & Tripp, Z. D. (1996) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32560-8 · Cited by 106
Regional Fat Aspiration for Body Contouring
Kesselring, U. K., & Kesselring, U. K. (1983) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198311000-00003 · Cited by 100
Influence of body water distribution on skin thickness: measurements using high-frequency ultrasound
Eisenbeiss, C., Welzel, J., Eichler, W., & Klotz, K.-F. (2001) · British Journal of Dermatology · doi:10.1046/j.1365-2133.2001.04180.x · Cited by 91
Blood loss during liposuction using the tumescent technique
Samdal, F., Amland, P. F., & Bugge, J. F. (1994) · Aesthetic Plastic Surgery · doi:10.1007/bf00454476 · Cited by 91
Large-Volume Suction Lipectomy: An Analysis of 108 Patients
Courtiss, E. H., Choucair, R. J., & Donelan, M. B. (1992) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199206000-00012 · Cited by 91
The Tumescent Technique for Liposuction Surgery
Lillis, P. J. (1990) · Dermatologic Clinics · doi:10.1016/s0733-8635(18)30475-3 · Cited by 83
Bafaqeeh, S. A., Al-Qattan, M. M., & Rohrich, R. J. (2000) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-200001000-00057 · Cited by 81
Self-citationSuction-Assisted Lipectomy, Suction Lipectomy, Lipolysis, and Lipexeresis
Grazer, F. M., & Grazer, F. M. (1983) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198311000-00004 · Cited by 81
Some New Injectable Dermal Filler Materials: Hylaform, Restylane, and Artecoll
Pollack, S. V. (1999) · Journal of Cutaneous Medicine and Surgery · doi:10.1177/12034754990030s406 · Cited by 75
History And Current Concepts Of Lipoplasty
Illouz, Y.-G. (1996) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32567-0 · Cited by 70
Courtiss, E. H. (1984) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198405000-00011 · Cited by 67
The effect of low-dose epinephrine on the hematocrit drop following lipolysis
Hetter, G. P. (1984) · Aesthetic Plastic Surgery · doi:10.1007/bf01572780 · Cited by 67
Clayton, D. N., Clayton, J. N., Lindley, T. S., & Clayton, J. L. (1989) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31344-4 · Cited by 63
Tissue Temperatures during Ultrasound-Assisted Lipoplasty
Ablaza, V. J., Gingrass, M. K., Perry, L. C., Fisher, J., & Maxwell, P. G. (1998) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199808000-00039 · Cited by 53
Teimourian, B., Adham, M. N., Gulin, S., & Shapiro, C. (1983) · Annals of Plastic Surgery · doi:10.1097/00000637-198308000-00001 · Cited by 53
Complications of the Tumescent Formula For Liposuction
Grazer, F. M., & Meister, F. L. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199712000-00040 · Cited by 51
Blood and Fluid Replacement for Lipoplasty Procedures
Retter, G. P. (1989) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31338-9 · Cited by 45
Fatal Necrotizing Fasciitis Following Suction-assisted Lipectomy
Alexander, J., Takeda, D., Sanders, G. B., & Goldberg, H. M. (1988) · Annals of Plastic Surgery · doi:10.1097/00000637-198806000-00012 · Cited by 39
Improved Results with Closed Facial Suction
Hetter, G. P. (1989) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31346-8 · Cited by 39
Safety Issues In Ultrasound-Assisted Large-Volume Lipoplasty
Gilliland, M. D., Commons, G. W., & Halperin, B. D. (1999) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32619-5 · Cited by 38
Safe Suction: Fluid Replacement and Blood Loss Parameters
Pitman, G. H., & Holzer, J. A. (1991) · Seminars in Plastic Surgery · doi:10.1055/s-2008-1080416 · Cited by 18
Factors contributing to adverse effects of the tumescent technique*
Grazer, F. M., & Meister, F. L. (1997) · Aesthetic Surgery Journal · doi:10.1016/s1090-820x(97)80060-x · Cited by 17
Cited by
Hróbjartsson, A., Thomsen, A. S. S., Emanuelsson, F., Tendal, B., Hilden, J., Boutron, I., Ravaud, P., & Brorson, S. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.120744 · Cited by 527
“40 Some researchers consider the blinding of outcome assessors too resource-demanding, superfluous, or misconceived; 41,42 however, planning and running a randomized clinical trial is already a logistically very challenging undertaking.”
BackgroundInfluences on Medical Student Career Choice: Gender or Generation?
Sanfey, H. A. (2006) · Archives of Surgery · doi:10.1001/archsurg.141.11.1086 · Cited by 306
The Wrinkle Severity Rating Scale: A Validation Study
Day, D. J., Littler, C. M., Swift, R. W., & Gottlieb, S. (2004) · American Journal of Clinical Dermatology · doi:10.2165/00128071-200405010-00007 · Cited by 284
Age estimation using a hierarchical classifier based on global and local facial features
Choi, S. E., Lee, Y. J., Lee, S. J., Park, K. R., & Kim, J. (2011) · Pattern Recognition · doi:10.1016/j.patcog.2010.12.005 · Cited by 260
Age‐related changes in skin mechanical properties: a quantitative evaluation of 120 female subjects
Krueger, N., Luebberding, S., Oltmer, M., Streker, M., & Kerscher, M. (2011) · Skin Research and Technology · doi:10.1111/j.1600-0846.2010.00486.x · Cited by 209
Metadata
- Authors
- Rohrich, R. J.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2001-11
- Volume
- 108
- Issue
- 6
- Pages
- 1733-1734
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2040995707
- Cited by
- 277
- References
- 36
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.