CoChat

Palpitations and Cardiac Awareness After Heart Transplantation

Barsky, Arthur J., Ahern, David K., Brener, Jasper, Surman, Owen S., Ring, Christopher, Dec, G. William · 1998 · Psychosomatic Medicine
Cited by 41

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The aim of this study was to examine the awareness of resting heartbeat in heart transplantation recipients, compare it with that found in other medical populations, and determine whether clinical characteristics are associated with accurate heartbeat awareness. METHODS: Eligible patients underwent a research battery consisting of a heartbeat detection task and self-report questionnaires assessing cardiac symptoms, psychosocial variables, and cognitive function. The accurate awareness of resting heartbeat was determined by presenting the patients with auditory stimuli at each of six different delays following the R wave on the ECG. Patients then selected the tones that they thought coincided with the sensation they had of their heart beating. The patients' physicians rated their cardiac morbidity. The results were contrasted with comparable data obtained in previous work with other ambulatory medical populations. RESULTS: Forty-one consecutive heart transplantation recipients who survived for at least 3 months after surgery were eligible. Thirty-four (82.9%) of them were studied and complete data were obtained on 26 (63.4%). Nine patients (34.6%) were reliably able to detect their resting heartbeat. When compared with the 17 patients who were not accurately aware of their heartbeat, the two groups did not differ significantly in cardiac morbidity, cognitive brain dysfunction, generalized psychiatric distress, depression, somatization, or hypochondriacal attitudes. A significantly higher proportion of heart transplantation recipients were accurately aware of their heartbeat than was found in a sample of general medical outpatients and in asymptomatic, nonpatient volunteers. CONCLUSIONS: One-third of heart transplant recipients are accurately aware of resting heartbeat, despite the absence of cardiac innervation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006842-199809000-00007

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 41

Metadata

Authors
Barsky, A. J., Ahern, D. K., Brener, J., Surman, O. S., Ring, C., & Dec, G. W.
Venue
Psychosomatic Medicine
Published
1998
Volume
60
Issue
5
Pages
557-562
ISSN
0033-3174 (ISSN-L)
OpenAlex
W2024461199
Cited by
41
References
7
FWCI
1.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Palpitations and Cardiac Awareness After Heart Transplantation. https://app.cochat.ai/papers/10.1097/00006842-199809000-00007
The paper
Barsky, A. J., Ahern, D. K., Brener, J., Surman, O. S., Ring, C., & Dec, G. W. (1998). Palpitations and Cardiac Awareness After Heart Transplantation. Psychosomatic Medicine. https://doi.org/10.1097/00006842-199809000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.