The DOI matches its Crossref record.
Image-Guided Insertion of Transpedicular Screws: A Laboratory Set-Up
Abstract
STUDY DESIGN: A computer-assisted system allowing precise preoperative planning and real-time intraoperative image localization of surgical instruments is tested in a laboratory setup. OBJECTIVES: The purpose of this study is to assess the applicability, functionality, and accuracy of this transpedicular spinal fixation technique. SUMMARY OF BACKGROUND DATA: Most techniques in transpedicular spinal fixation rely on the identification of predefined targets with the help of anatomic landmarks and on the intraoperative use of image intensifiers. Various studies report considerable screw misplacement rates which may lead to serious clinical sequelae such as permanent nerve damage. METHODS: The proposed system was tested in an in vitro setup drilling 20 pedicle pilot holes in lumbar vertebrae. The accuracy was assessed using precision cuts through the pedicles and simulation of a 6-mm pedicle screw insertion. RESULTS: An ideal screw position was found in 70 of 77 cuts, and in no case was an injury to the pedicular cortex observed. CONCLUSIONS: The presented technique provides a safe, accurate, and flexible basis for transpedicular screw placement in the spine. This approach should be further evaluated in clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Amiot, L.-P., Lang, K., Putzier, M., Zippel, H., & Labelle, H. (2000) · Spine · doi:10.1097/00007632-200003010-00012 · Cited by 450
Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007) · Spine · doi:10.1097/01.brs.0000252094.64857.ab · Cited by 358
Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997) · Spine · doi:10.1097/00007632-199702150-00020 · Cited by 284
Self-citationLaine, T., Schlenzka, D., Mäkitalo, K., Tallroth, K., Nolte, L.-P., & Visarius, H. (1997) · Spine · doi:10.1097/00007632-199706010-00018 · Cited by 277
Self-citationA new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation
Nolte, L. P., Slomczykowski, M. A., Berlemann, U., Strauss, M. J., Hofstetter, R., Schlenzka, D., Laine, T., & Lund, T. (2000) · European Spine Journal · doi:10.1007/pl00010026 · Cited by 159
Self-citation
Metadata
- Authors
- Nolte, L.-P., Zamorano, L. J., Jiang, Z., Wang, Q., Langlotz, F., & Berlemann, U.
- Venue
- Spine
- Published
- 1995-02
- Volume
- 20
- Issue
- supplement
- Pages
- 497-500
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2180660871
- Cited by
- 197
- References
- 0
- FWCI
- 15.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image-Guided Insertion of Transpedicular Screws: A Laboratory Set-Up. https://app.cochat.ai/papers/10.1097/00007632-199502001-00016
- The paper
- Nolte, L.-P., Zamorano, L. J., Jiang, Z., Wang, Q., Langlotz, F., & Berlemann, U. (1995). Image-Guided Insertion of Transpedicular Screws: A Laboratory Set-Up. Spine. https://doi.org/10.1097/00007632-199502001-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.