Pitfalls in the Measurement of Bone Mineral Density by Dual Energy X-ray Absorptiometry
The DOI matches its Crossref record.
Abstract
STUDY DESIGN: Fifty-three human thoracic and lumbar vertebrae were analyzed by dual energy x-ray absorptiomety to obtain projectional (g/cm2) and volumetric (g/cm3) bone mineral density. OBJECTIVES: To determine the effect of volume on the measurement of bone mineral density by DEXA. SUMMARY OF BACKGROUND DATA: Despite the widespread use of dual energy x-ray absorptiomety to measure bone mineral density expressed as grams per projectional unit area (g/cm2), the effect of volume has been ignored in many published biomechanical studies. METHODS: Projectional bone mineral density (g/cm2) of fifty-three human vertebrae was obtained by dual energy x-ray absorptiometry measurement. This was compared to bone mineral density expressed as grams per unit volume. RESULTS: Many specimens with near equal projectional bone mineral density were demonstrated to have significantly different true densities when measured by dual energy x-ray absorptiomety in grams per unit volume. The difference in true bone mineral density for these specimens ranged from 24.1% to 139%. CONCLUSION: The effect of volume on bone mineral density data based on projectional areas can cause very significant perturbations of the data in biomechanical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bolotin, H. H. (2007) · Bone · doi:10.1016/j.bone.2007.02.022 · Cited by 274
“A number of the most salient of these have been highlighted in recent research studies, mini-reviews, and perspective journal articles [1–21].”
BackgroundResultDual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Kaesmacher, J., Liebl, H., Baum, T., & Kirschke, J. S. (2017) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000518 · Cited by 50
Metadata
- Authors
- Antonacci, M. D., Hanson, D. S., & Heggeness, M. H.
- Venue
- Spine
- Published
- 1996-01
- Volume
- 21
- Issue
- 1
- Pages
- 87-90
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2024509809
- Cited by
- 42
- References
- 0
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pitfalls in the Measurement of Bone Mineral Density by Dual Energy X-ray Absorptiometry. https://app.cochat.ai/papers/10.1097/00007632-199601010-00020
- The paper
- Antonacci, M. D., Hanson, D. S., & Heggeness, M. H. (1996). Pitfalls in the Measurement of Bone Mineral Density by Dual Energy X-ray Absorptiometry. Spine. https://doi.org/10.1097/00007632-199601010-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.