Lumbar Range of Motion: Reliability and Validity of the Inclinometer Technique in the Clinical Measurement of Trunk Flexibility
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: This study examines the reliability and validity of measuring lumbar range of motion with an inclinometer. OBJECTIVES: To find out whether a manual determination of the reference points for measuring lumbar range of motion is as reliable as radiologic determination for positioning the inclinometers, lumbar range of motion was determined in degrees by evaluating radiographs and by using the inclinometer technique of Loebl. SUMMARY OF BACKGROUND DATA: Reliability and validity of the inclinometer technique as a clinical measurement of trunk flexibility were investigated. Fifty-four patients participated in the study. METHODS: Lumbar range of motion measurements were taken with and without radiologic control of the T12 and S1 vertebrae as reference points for positioning of the inclinometers. An interrater correlation was done of the inclinometer techniques of a physician and a physiotherapist. Functional radiographs were investigated in a standing position. Lumbar range of motion measurements based on radiographs and those taken using the inclinometer alone were correlated to validate the inclinometer technique. RESULTS: Lumbar range of motion measurements taken with and without radiologic determination showed a very close correlation (r = 0.93; P < 0.001). Flexion alone also demonstrated a close correlation (r = 0.95; P < 0.001), whereas extension showed a somewhat smaller correlation (r = 0.82; P < 0.001). Total lumbar range of motion (r = 0.94; P < 0.001) and flexion (r = 0.88; P < 0.001) were closely related, as indicated by the interrater correlation, whereas extension (r = 0.42; P < 0.05) showed a lesser correlation. Correlation of the measurements taken radiographically and by inclinometer demonstrated an almost linear correlation for measurements of the total lumbar range of motion (r = 0.97; P < 0.001) and flexion (r = 0.98; P < 0.001), whereas extension (r = 0.75; P < 0.001) did not correlate as well. CONCLUSIONS: The noninvasive inclinometer technique proved to be highly reliable and valid, but the measurement technique for extension needs further refinement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Macrae, I. F., & Wright, V (1969) · Annals of the Rheumatic Diseases · doi:10.1136/ard.28.6.584 · Cited by 389
Roentgenographic Evaluation of Lumbar Spine Flexion-Extension in Asymptomatic Individuals
HAYES, M. A., HOWARD, T. C., GRUEL, C. R., & KOPTA, J. A. (1989) · Spine · doi:10.1097/00007632-198903000-00014 · Cited by 296
MAYER, T. G., TENCER, A. F., KRISTOFERSON, S., & MOONEY, V. (1984) · Spine · doi:10.1097/00007632-198409000-00009 · Cited by 291
MEASUREMENT OF SPINAL POSTURE AND RANGE OF SPINAL MOVEMENT
LOEBL, W. Y. (1967) · Rheumatology · doi:10.1093/rheumatology/9.3.103 · Cited by 149
Reliability of Clinical Measurements of Forward Bending Using the Modified Fingertip-to-Floor Method
Gauvin, M. G., Riddle, D. L., & Rothstein, J. M. (1990) · Physical Therapy · doi:10.1093/ptj/70.7.443 · Cited by 148
Reliability and Validity of Four Instruments for Measuring Lumbar Spine and Pelvic Positions
Burdett, R. G., Brown, K. E., & Fall, M. P. (1986) · Physical Therapy · doi:10.1093/ptj/66.5.677 · Cited by 129
Quantification of Lumbar Function
Keeley, J., Mayer, T. G., Cox, R., Gatchel, R. J., SMITH, J., & Mooney, V. (1986) · Spine · doi:10.1097/00007632-198601000-00009 · Cited by 124
Reproducibility of nine tests to measure spinal mobility and trunk muscle strength
Hyytiäinen, K., Salminen, J. J., Suvitie, T., Wickström, G. J., & Pentti, J. (2020) · Journal of Rehabilitation Medicine · doi:10.2340/165019779123310 · Cited by 104
MEASUREMENTS OF THE SAGITTAL MOBILITY OF THE LUMBAR SPINE AND HIPS
Troup, J. D. G., Hood, C. A., & Chapman, A. E. (1968) · Rheumatology · doi:10.1093/rheumatology/9.8.308 · Cited by 100
Measurement of Thoracolumbar Posture and Mobility with a Myrin Inclinometer
Mellin, G. P. (1986) · Spine · doi:10.1097/00007632-198609000-00019 · Cited by 93
Variation in Lumbar Sagittal Mobility with Low-Back Trouble
Burton, K. A., Tillotson, K. M., & Troup, J. D. G. (1989) · Spine · doi:10.1097/00007632-198906000-00007 · Cited by 92
Spinal Flexibility and Individual Factors That Influence It
Battié, M. C., Bigos, S. J., Sheehy, A., & WORTLEY, M. D. (1987) · Physical Therapy · doi:10.1093/ptj/67.5.653 · Cited by 81
Reliability of the Attraction Method for Measuring Lumbar Spine Backward Bending
Beattie, P., Rothstein, J. M., & Lamb, R. L. (1987) · Physical Therapy · doi:10.1093/ptj/67.3.364 · Cited by 48
Chiarello, C. M., & Savidge, R. (1993) · PubMed · Cited by 46
Pfingsten, M., Ensink, F. B. M., Franz, C., Hildebrandt, J., Saur, P. M. M., Schwibbe, G., Steinmetz, U., & Straub, A. (1993) · Journal of Public Health · doi:10.1007/bf02959666 · Cited by 15
Self-citation
Cited by
O'Sullivan, P. B., Phyty, G. D. M., Twomey, L. T., & Allison, G. T. (1997) · Spine · doi:10.1097/00007632-199712150-00020 · Cited by 1,109
Delitto, A., George, S. Z., Van Dillen, L., Whitman, J. M., Sowa, G., Shekelle, P., Denninger, T. R., & Godges, J. J. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.42.4.a1 · Cited by 919
Tousignant, M., Poulin, L., Marchand, S., Viau, A., & Place, C. (2005) · Disability and Rehabilitation · doi:10.1080/09638280400018411 · Cited by 179
Mika, A., Unnithan, V. B., & Mika, P. (2005) · Spine · doi:10.1097/01.brs.0000150521.10071.df · Cited by 164
Walicka-Cupryś, K., Wyszyńska, J., Podgórska-Bednarz, J., & Drzał-Grabiec, J. (2018) · European Spine Journal · doi:10.1007/s00586-017-5409-8 · Cited by 31
Metadata
- Authors
- Saur, P. M. M., Ensink, F.-B. M., Frese, K., Seeger, D., & Hildebrandt, J.
- Venue
- Spine
- Published
- 1996-06
- Volume
- 21
- Issue
- 11
- Pages
- 1332-1338
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2082161122
- Cited by
- 238
- References
- 15
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.