Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Navigation and Robotics in Spinal Surgery: Where Are We Now?

Overley, Samuel C., Cho, Samuel K., Mehta, Ankit I., Arnold, Paul M.·2017·Neurosurgery

Abstract

Spine surgery has experienced much technological innovation over the past several decades. The field has seen advancements in operative techniques, implants and biologics, and equipment such as computer-assisted navigation and surgical robotics. With the arrival of real-time image guidance and navigation capabilities along with the computing ability to process and reconstruct these data into an interactive three-dimensional spinal “map”, so too have the applications of surgical robotic technology. While spinal robotics and navigation represent promising potential for improving modern spinal surgery, it remains paramount to demonstrate its superiority as compared to traditional techniques prior to assimilation of its use amongst surgeons. The applications for intraoperative navigation and image-guided robotics have expanded to surgical resection of spinal column and intradural tumors, revision procedures on arthrodesed spines, and deformity cases with distorted anatomy. Additionally, these platforms may mitigate much of the harmful radiation exposure in minimally invasive surgery to which the patient, surgeon, and ancillary operating room staff are subjected. Spine surgery relies upon meticulous fine motor skills to manipulate neural elements and a steady hand while doing so, often exploiting small working corridors utilizing exposures that minimize collateral damage. Additionally, the procedures may be long and arduous, predisposing the surgeon to both mental and physical fatigue. In light of these characteristics, spine surgery may actually be an ideal candidate for the integration of navigation and robotic-assisted procedures. With this paper, we aim to critically evaluate the current literature and explore the options available for intraoperative navigation and robotic-assisted spine surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/neuros/nyw077

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Research works printed but not linked: 75

  1. Marcus, 2014, Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review, Eur Spine J, 23, 291, 10.1007/s00586-013-2879-1 · doi:10.1007/s00586-013-2879-1
  2. Kelly, 2002, Neurosurgical robotics, Clin Neurosurg, 49, 136
  3. Han, 2010, Pedicle screw placement in the thoracic spine: a comparison study of computer-assisted navigation and conventional techniques, Orthopedics, 33, 10.3928/01477447-20100625-14 · doi:10.3928/01477447-20100625-14
  4. Ishikawa, 2010, Clinical accuracy of three-dimensional fluoroscopybased computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. Clinical article, J Neurosurg Spine, 13, 606, 10.3171/2010.5.SPINE09993 · doi:10.3171/2010.5.spine09993
  5. Ito, 2007, Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients, Rheumatol Int, 27, 567, 10.1007/s00296-006-0256-7 · doi:10.1007/s00296-006-0256-7
  6. Kotani, 2003, Improved accuracy of computer-assisted cervical pedicle screw insertion, J Neurosurg, 99, 257
  7. Kotani, 2007, Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique, Spine, 32, 1543, 10.1097/BRS.0b013e318068661e · doi:10.1097/brs.0b013e318068661e
  8. Laine, 2000, Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients, Eur Spine J, 9, 235, 10.1007/s005860000146 · doi:10.1007/s005860000146
  9. Lee, 2007, Clinical accuracy of cervicothoracic pedicle screw placement: a comparison of the “open” lamino-foraminotomy and computer-assisted techniques, J Spinal Disord Tech, 20, 25, 10.1097/01.bsd.0000211239.21835.ad · doi:10.1097/01.bsd.0000211239.21835.ad
  10. Liu, 2005, Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique, Zhonghua Wai Ke Za Zhi, 43, 1328
  11. Nakashima, 2009, Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery, J Spinal Disord Tech, 22, 468, 10.1097/BSD.0b013e31819877c8 · doi:10.1097/bsd.0b013e31819877c8
  12. Richter, 2005, Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws, Spine, 30, 2280, 10.1097/01.brs.0000182275.31425.cd · doi:10.1097/01.brs.0000182275.31425.cd
  13. Sakai, 2008, Segmental pedicle screwing for idiopathic scoliosis using computer-assisted surgery, J Spinal Disord Tech, 21, 181, 10.1097/BSD.0b013e318074d388 · doi:10.1097/bsd.0b013e318074d388
  14. Schnake, 2004, Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique, Unfallchirurg, 107, 104
  15. Seller, 2005, Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation., Biomed Tech (Berl), 50, 287, 10.1515/BMT.2005.043 · doi:10.1515/bmt.2005.043
  16. Tian, 2006, Clinical contrast of cervical pedicle screw fixation assisted by C-arm fluoroscopy or 3D navigation system., Zhonghua Wai Ke Za Zhi, 44, 1399
  17. Tormenti, 2010, Intraoperative computed tomography imageguided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery, Neurosurg Focus, 28, 1, 10.3171/2010.1.FOCUS09275 · doi:10.3171/2010.1.focus09275
  18. Rajan, 2010, Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine, Indian J Orthop, 44, 163, 10.4103/0019-5413.62083 · doi:10.4103/0019-5413.62083
  19. Wang, 2008, Computer-assisted pedicle screw placement for thoracolumbar spine fracture with separate spinal reference clamp placement and registration, Surg Neurol, 69, 597, 10.1016/j.surneu.2007.04.006 · doi:10.1016/j.surneu.2007.04.006
  20. Fu, 2004, Computer-assisted fluoroscopic navigation of pedicle screw insertion: an in vivo feasibility study, Acta Orthop Scand, 75, 730, 10.1080/00016470410004102 · doi:10.1080/00016470410004102
  21. Carl, 2000, In vivo pedicle screw placement: image-guided virtual vision, J Spinal Disord, 13, 225, 10.1097/00002517-200006000-00005 · doi:10.1097/00002517-200006000-00005
  22. Girardi, 1999, The placement of lumbar pedicle screws using computerised stereotactic guidance, J Bone Joint Surg Br, 81, 825, 10.1302/0301-620X.81B5.0810825 · doi:10.1302/0301-620x.81b5.0810825
  23. Rajasekaran, 2007, Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries, Spine, 32, 56, 10.1097/01.brs.0000252094.64857.ab · DOI · Paper page
  24. Tang, 2014, Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine: a meta-analysis of comparative studies, J Biomed Res, 28, 228, 10.7555/JBR.28.20130159 · doi:10.7555/jbr.28.20130159
  25. Marcus, 2014, Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review, Eur Spine J, 23, 291, 10.1007/s00586-013-2879-1 · doi:10.1007/s00586-013-2879-1
  26. Shin, 2012, Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion, J Neurosurg Spine, 17, 113, 10.3171/2012.5.SPINE11399 · doi:10.3171/2012.5.spine11399
  27. Arand, 2002, Spinal navigation in tumor surgery of the thoracic spine: first clinical results, Clin Orthop Relat Res, 211, 10.1097/00003086-200206000-00026 · doi:10.1097/00003086-200206000-00026
  28. Rajasekaran, 2008, Intraoperative Iso-C three-dimensional navigation in excision of spinal osteoid osteomas, Spine, 33, E25, 10.1097/BRS.0b013e31815e6308 · doi:10.1097/brs.0b013e31815e6308
  29. Van Royen, 2005, Osteoid osteoma of the spine: a novel technique using combined computer-assisted and gamma probe-guided high-speed intralesional drill excision, Spine, 30, 369, 10.1097/01.brs.0000152531.49095.34 · doi:10.1097/01.brs.0000152531.49095.34
  30. Smitherman, 2010, Image-guided multilevel vertebral osteotomies for en bloc resection of giant cell tumor of the thoracic spine: case report and description of operative technique, Eur Spine J, 19, 1021, 10.1007/s00586-009-1273-5 · doi:10.1007/s00586-009-1273-5
  31. Reid, 1978, Ultrasonic visualization of a cervical cord cystic astrocytoma, AJR Am J Roentgenol, 131, 907, 10.2214/ajr.131.5.907 · doi:10.2214/ajr.131.5.907
  32. Epstein, 1991, Intraoperative ultrasonography: an important surgical adjunct for intramedullary tumors, J Neurosurg, 74, 729, 10.3171/jns.1991.74.5.0729 · doi:10.3171/jns.1991.74.5.0729
  33. Regelsberger, 2005, Intraoperative sonography of intra- and extramedullary tumors, Ultrasound Med Biol, 31, 593, 10.1016/j.ultrasmedbio.2005.01.016 · doi:10.1016/j.ultrasmedbio.2005.01.016
  34. Bozinov, 2012, Intra-operative high frequency ultrasound improves surgery of intramedullary cavernous malformations, Neurosurg Rev, 35, 269, 10.1007/s10143-011-0364-z · doi:10.1007/s10143-011-0364-z
  35. Friedman, 2000, Migration of an intraspinal schwannoma documented by intraoperative ultrasound: case report, Surg Neurol, 54, 455, 10.1016/S0090-3019(00)00314-1 · doi:10.1016/s0090-3019(00)00314-1
  36. Kolstad, 2006, Three-dimensional ultrasonography navigation in spinal cord tumor surgery. Technical note, J Neurosurg Spine, 5, 264, 10.3171/spi.2006.5.3.264 · doi:10.3171/spi.2006.5.3.264
  37. Maiuri, 1997, The role of intraoperative sonography in reducing invasiveness during surgery for spinal tumors, Minim Invasive Neurosurg, 40, 8, 10.1055/s-2008-1053405 · doi:10.1055/s-2008-1053405
  38. Maiuri, 2000, Intraoperative sonography for spinal tumors. Correlations with MR findings and surgery, J Neurosurg Sci, 44, 115
  39. Zhou, 2011, Intraoperative ultrasound assistance in treatment of intradural spinal tumours, Clin Neurol Neurosurg, 113, 531, 10.1016/j.clineuro.2011.03.006 · doi:10.1016/j.clineuro.2011.03.006
  40. Prada, 2014, Intraoperative ultrasound in spinal tumor surgery, J Ultrasound, 17, 195, 10.1007/s40477-014-0102-9 · doi:10.1007/s40477-014-0102-9
  41. D’Andrea, 2015, Utility of preoperative magnetic resonance imaging coregistered with intraoperative computed tomographic scan for the resection of complex tumors of the spine, World Neurosurg, 84, 1804, 10.1016/j.wneu.2015.07.072 · doi:10.1016/j.wneu.2015.07.072
  42. Leksell, 1985, Stereotaxis and nuclear magnetic resonance. A technical note, J Neurol Neurosurg Psychiatry, 48, 14, 10.1136/jnnp.48.1.14 · doi:10.1136/jnnp.48.1.14
  43. Cohen, 1995, Effects of coregistration of MR to CT images on MR stereotactic accuracy, J Neurosurg, 82, 772, 10.3171/jns.1995.82.5.0772 · doi:10.3171/jns.1995.82.5.0772
  44. Bradford, 1987, MRI-directed stereotactic biopsy of cerebral lesions, Acta Neurochir, 39, 25
  45. Lévesque, 1990, Stereotactic investigation of limbic epilepsy using a multimodal image analysis system. Technical note, J Neurosurg, 73, 792, 10.3171/jns.1990.73.5.0792 · doi:10.3171/jns.1990.73.5.0792
  46. Kamogawa, 2009, The 3D-MRI/MRA/CT Fusion Imaging in spine and spinal cord disorders focusing on upper cervical spine: report of two cases, Spine Spinal Cord, 22, 979
  47. Kamagoawa, 2015, Virtual pathology of cervical radiculopathy based on 3D MR/CT fusion images: impingement, flattening or twisted condition of the compressed nerve root in three cases, Springerplus, 4, 123, 10.1186/s40064-015-0898-6 · doi:10.1186/s40064-015-0898-6
  48. Castro, 1996, Accuracy of pedicle screw placement in lumbar vertebrae, Spine, 21, 1320, 10.1097/00007632-199606010-00008 · doi:10.1097/00007632-199606010-00008
  49. Laine, 1997, Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients, Eur Spine J, 6, 402, 10.1007/BF01834068 · doi:10.1007/bf01834068
  50. Wiesner, 2000, Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine, Spine, 25, 615, 10.1097/00007632-200003010-00013 · doi:10.1097/00007632-200003010-00013
  51. Seichi, 2005, Revision cervical spine surgery using transarticular or pedicle screws under a computer-assisted imageguidance system, J Orthop Sci, 10, 385, 10.1007/s00776-005-0902-z · doi:10.1007/s00776-005-0902-z
  52. Jones, 1997, Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison, Spine, 22, 977, 10.1097/00007632-199705010-00009 · doi:10.1097/00007632-199705010-00009
  53. Kotani, 1994, Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine, Spine, 19, 2529, 10.1097/00007632-199411001-00007 · doi:10.1097/00007632-199411001-00007
  54. Allam, 2013, Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques, Eur Spine J, 22, 648, 10.1007/s00586-012-2505-7 · doi:10.1007/s00586-012-2505-7
  55. Luther, 2015, Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: Screw accuracy, screw size, and the complexity of surgery, J Spinal Disord Tech, 28, E298, 10.1097/BSD.0b013e31828af33e · doi:10.1097/bsd.0b013e31828af33e
  56. Theocharopoulos, 2003, Occupational exposure from common fluoroscopic projections used in orthopaedic surgery, J Bone Joint Surg Am, 85, 1698, 10.2106/00004623-200309000-00007 · doi:10.2106/00004623-200309000-00007
  57. Mroz, 2011, Radiation exposure to the surgeon during percutaneous pedicle screw placement, J Spinal Disord Tech, 24, 264, 10.1097/BSD.0b013e3181eed618 · doi:10.1097/bsd.0b013e3181eed618
  58. Rampersaud, 2000, Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion, Spine, 25, 2637, 10.1097/00007632-200010150-00016 · doi:10.1097/00007632-200010150-00016
  59. Bindal, 2008, Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion, J Neurosurg Spine, 9, 570, 10.3171/SPI.2008.4.08182 · doi:10.3171/spi.2008.4.08182
  60. Taher, 2013, 2013 Young Investigator Award winner: how safe is lateral lumbar interbody fusion for the surgeon? A prospective in vivo radiation exposure study, Spine, 38, 1386, 10.1097/BRS.0b013e31828705ad · doi:10.1097/brs.0b013e31828705ad
  61. Kim, 2008, Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery, Spine J, 8, 584, 10.1016/j.spinee.2006.12.012 · doi:10.1016/j.spinee.2006.12.012
  62. Kraus, 2010, Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?, Clin Orthop Relat Res, 468, 2419, 10.1007/s11999-010-1393-6 · doi:10.1007/s11999-010-1393-6
  63. Lieberman, 2006, Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part I–Technical development and a test case result, Neurosurgery, 59, 641, 10.1227/01.NEU.0000229055.00829.5B · doi:10.1227/01.neu.0000229055.00829.5b
  64. Togawa, 2007, Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2–Evaluation of system accuracy, Neurosurgery, 60, ONS129
  65. Roser, 2013, Maier G Spinal robotics: current applications and future perspectives, Neurosurgery, 72, 12, 10.1227/NEU.0b013e318270d02c · doi:10.1227/neu.0b013e318270d02c
  66. Schizas, 2012, Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy, Acta Orthop Belg, 78, 240
  67. Kantelhardt, 2011, Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement, Eur Spine J, 20, 860, 10.1007/s00586-011-1729-2 · doi:10.1007/s00586-011-1729-2
  68. Lonjon, 2016, Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis, Eur Spine J, 25, 947, 10.1007/s00586-015-3758-8 · doi:10.1007/s00586-015-3758-8
  69. Obenchain, 1991, Laparoscopic lumbar discectomy: case report, J Laparoendosc Surg, 1, 145, 10.1089/lps.1991.1.145 · doi:10.1089/lps.1991.1.145
  70. Inamasu, 2005, Laparoscopic anterior lumbar interbody fusion: a review of outcome studies, Minim Invasive Neurosurg, 48, 340, 10.1055/s-2005-915634 · doi:10.1055/s-2005-915634
  71. Liu, 2002, Is laparoscopic anterior lumbar interbody fusion a useful minimally invasive procedure?, Neurosurgery, 51, S155, 10.1097/00006123-200211002-00021 · doi:10.1097/00006123-200211002-00021
  72. Chung, 2003, Comparative study of laparoscopic L5-S1 fusion versus open mini-ALIF, with a minimum 2-year follow-up, Eur Spine J, 12, 613, 10.1007/s00586-003-0526-y · doi:10.1007/s00586-003-0526-y
  73. Lee, 2013, Technique and surgical outcomes of robot-assisted anterior lumbar interbody fusion, J Robot Surg, 7, 177, 10.1007/s11701-012-0365-0 · doi:10.1007/s11701-012-0365-0
  74. Lee, 2013, Minimally invasive, robot-assisted, anterior lumbar interbody fusion: a technical note, J Neurol Surg A Cent Eur Neurosurg, 74, 258, 10.1055/s-0032-1330121 · doi:10.1055/s-0032-1330121
  75. Yang, 2011, Robot-assisted anterior lumbar interbody fusion in a Swine model in vivo test of the da vinci surgical-assisted spinal surgery system, Spine, 36, E139, 10.1097/BRS.0b013e3181d40ba3 · doi:10.1097/brs.0b013e3181d40ba3

Cited by

See all 327

Metadata

Authors
Overley, S. C., Cho, S. K., Mehta, A. I., & Arnold, P. M.
Venue
Neurosurgery
Published
2017-02-21
Volume
80
Issue
3S
Pages
S86-S99
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2590852980
Cited by
327
References
25
FWCI
25.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Navigation and Robotics in Spinal Surgery: Where Are We Now? https://app.cochat.ai/papers/10.1093/neuros/nyw077
The paper
Overley, S. C., Cho, S. K., Mehta, A. I., & Arnold, P. M. (2017). Navigation and Robotics in Spinal Surgery: Where Are We Now? Neurosurgery. https://doi.org/10.1093/neuros/nyw077

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.