The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Navigation and Robotics in Spinal Surgery: Where Are We Now?
Abstract
Spine surgery has experienced much technological innovation over the past several decades. The field has seen advancements in operative techniques, implants and biologics, and equipment such as computer-assisted navigation and surgical robotics. With the arrival of real-time image guidance and navigation capabilities along with the computing ability to process and reconstruct these data into an interactive three-dimensional spinal “map”, so too have the applications of surgical robotic technology. While spinal robotics and navigation represent promising potential for improving modern spinal surgery, it remains paramount to demonstrate its superiority as compared to traditional techniques prior to assimilation of its use amongst surgeons. The applications for intraoperative navigation and image-guided robotics have expanded to surgical resection of spinal column and intradural tumors, revision procedures on arthrodesed spines, and deformity cases with distorted anatomy. Additionally, these platforms may mitigate much of the harmful radiation exposure in minimally invasive surgery to which the patient, surgeon, and ancillary operating room staff are subjected. Spine surgery relies upon meticulous fine motor skills to manipulate neural elements and a steady hand while doing so, often exploiting small working corridors utilizing exposures that minimize collateral damage. Additionally, the procedures may be long and arduous, predisposing the surgeon to both mental and physical fatigue. In light of these characteristics, spine surgery may actually be an ideal candidate for the integration of navigation and robotic-assisted procedures. With this paper, we aim to critically evaluate the current literature and explore the options available for intraoperative navigation and robotic-assisted spine surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of Pedicular Screw Placement In Vivo
GERTZBEIN, S. D., & ROBBINS, S. E. (1990) · Spine · doi:10.1097/00007632-199001000-00004 · Cited by 1,381
Robotic Surgery: A Current Perspective
Lanfranco, A. R., Castellanos, A. E., Desai, J. P., & Meyers, W. C. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000103020.19595.7d · Cited by 1,299
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Gelalis, I. D., Paschos, N. K., Pakos, E. E., Politis, A. N., Arnaoutoglou, C. M., Karageorgos, A., Ploumis, A., & Xenakis, T. A. (2011) · European Spine Journal · doi:10.1007/s00586-011-2011-3 · Cited by 674
A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
Roberts, D. W., Strohbehn, J. W., Hatch, J. F., Murray, W. T., & Kettenberger, H. (1986) · Journal of neurosurgery · doi:10.3171/jns.1986.65.4.0545 · Cited by 640
Amiot, L.-P., Lang, K., Putzier, M., Zippel, H., & Labelle, H. (2000) · Spine · doi:10.1097/00007632-200003010-00012 · Cited by 450
Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007) · Spine · doi:10.1097/01.brs.0000252094.64857.ab · Cited by 358
Accuracy of Robot-Assisted Placement of Lumbar and Sacral Pedicle Screws
Ringel, F. A., Stüer, C., Reinke, A. N., Preuß, A., Behr, M., Auer, F., Stoffel, M. H., & Meyer, B. (2012) · Spine · doi:10.1097/brs.0b013e31824b7767 · Cited by 347
Bone-mounted miniature robot for surgical procedures: concept and clinical applications
Shoham, M., Burman, M., Zehavi, E., Joskowicz, L., Batkilin, E., & Kunicher, Y. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817075 · Cited by 292
Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997) · Spine · doi:10.1097/00007632-199702150-00020 · Cited by 284
Research works printed but not linked: 75
- Marcus, 2014, Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review, Eur Spine J, 23, 291, 10.1007/s00586-013-2879-1 · doi:10.1007/s00586-013-2879-1
- Kelly, 2002, Neurosurgical robotics, Clin Neurosurg, 49, 136
- Han, 2010, Pedicle screw placement in the thoracic spine: a comparison study of computer-assisted navigation and conventional techniques, Orthopedics, 33, 10.3928/01477447-20100625-14 · doi:10.3928/01477447-20100625-14
- Ishikawa, 2010, Clinical accuracy of three-dimensional fluoroscopybased computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. Clinical article, J Neurosurg Spine, 13, 606, 10.3171/2010.5.SPINE09993 · doi:10.3171/2010.5.spine09993
- Ito, 2007, Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients, Rheumatol Int, 27, 567, 10.1007/s00296-006-0256-7 · doi:10.1007/s00296-006-0256-7
- Kotani, 2003, Improved accuracy of computer-assisted cervical pedicle screw insertion, J Neurosurg, 99, 257
- Kotani, 2007, Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique, Spine, 32, 1543, 10.1097/BRS.0b013e318068661e · doi:10.1097/brs.0b013e318068661e
- Laine, 2000, Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients, Eur Spine J, 9, 235, 10.1007/s005860000146 · doi:10.1007/s005860000146
- Lee, 2007, Clinical accuracy of cervicothoracic pedicle screw placement: a comparison of the “open” lamino-foraminotomy and computer-assisted techniques, J Spinal Disord Tech, 20, 25, 10.1097/01.bsd.0000211239.21835.ad · doi:10.1097/01.bsd.0000211239.21835.ad
- Liu, 2005, Accuracy of CT-based navigation of pedicle screws implantation in the cervical spine compared with X-ray fluoroscopy technique, Zhonghua Wai Ke Za Zhi, 43, 1328
- Nakashima, 2009, Comparison of the percutaneous screw placement precision of isocentric C-arm 3-dimensional fluoroscopy-navigated pedicle screw implantation and conventional fluoroscopy method with minimally invasive surgery, J Spinal Disord Tech, 22, 468, 10.1097/BSD.0b013e31819877c8 · doi:10.1097/bsd.0b013e31819877c8
- Richter, 2005, Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws, Spine, 30, 2280, 10.1097/01.brs.0000182275.31425.cd · doi:10.1097/01.brs.0000182275.31425.cd
- Sakai, 2008, Segmental pedicle screwing for idiopathic scoliosis using computer-assisted surgery, J Spinal Disord Tech, 21, 181, 10.1097/BSD.0b013e318074d388 · doi:10.1097/bsd.0b013e318074d388
- Schnake, 2004, Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique, Unfallchirurg, 107, 104
- Seller, 2005, Prospective screw misplacement analysis after conventional and navigated pedicle screw implantation., Biomed Tech (Berl), 50, 287, 10.1515/BMT.2005.043 · doi:10.1515/bmt.2005.043
- Tian, 2006, Clinical contrast of cervical pedicle screw fixation assisted by C-arm fluoroscopy or 3D navigation system., Zhonghua Wai Ke Za Zhi, 44, 1399
- Tormenti, 2010, Intraoperative computed tomography imageguided navigation for posterior thoracolumbar spinal instrumentation in spinal deformity surgery, Neurosurg Focus, 28, 1, 10.3171/2010.1.FOCUS09275 · doi:10.3171/2010.1.focus09275
- Rajan, 2010, Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine, Indian J Orthop, 44, 163, 10.4103/0019-5413.62083 · doi:10.4103/0019-5413.62083
- Wang, 2008, Computer-assisted pedicle screw placement for thoracolumbar spine fracture with separate spinal reference clamp placement and registration, Surg Neurol, 69, 597, 10.1016/j.surneu.2007.04.006 · doi:10.1016/j.surneu.2007.04.006
- Fu, 2004, Computer-assisted fluoroscopic navigation of pedicle screw insertion: an in vivo feasibility study, Acta Orthop Scand, 75, 730, 10.1080/00016470410004102 · doi:10.1080/00016470410004102
- Carl, 2000, In vivo pedicle screw placement: image-guided virtual vision, J Spinal Disord, 13, 225, 10.1097/00002517-200006000-00005 · doi:10.1097/00002517-200006000-00005
- Girardi, 1999, The placement of lumbar pedicle screws using computerised stereotactic guidance, J Bone Joint Surg Br, 81, 825, 10.1302/0301-620X.81B5.0810825 · doi:10.1302/0301-620x.81b5.0810825
- Rajasekaran, 2007, Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries, Spine, 32, 56, 10.1097/01.brs.0000252094.64857.ab · DOI · Paper page
- Tang, 2014, Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine: a meta-analysis of comparative studies, J Biomed Res, 28, 228, 10.7555/JBR.28.20130159 · doi:10.7555/jbr.28.20130159
- Marcus, 2014, Robot-assisted and fluoroscopy-guided pedicle screw placement: a systematic review, Eur Spine J, 23, 291, 10.1007/s00586-013-2879-1 · doi:10.1007/s00586-013-2879-1
- Shin, 2012, Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion, J Neurosurg Spine, 17, 113, 10.3171/2012.5.SPINE11399 · doi:10.3171/2012.5.spine11399
- Arand, 2002, Spinal navigation in tumor surgery of the thoracic spine: first clinical results, Clin Orthop Relat Res, 211, 10.1097/00003086-200206000-00026 · doi:10.1097/00003086-200206000-00026
- Rajasekaran, 2008, Intraoperative Iso-C three-dimensional navigation in excision of spinal osteoid osteomas, Spine, 33, E25, 10.1097/BRS.0b013e31815e6308 · doi:10.1097/brs.0b013e31815e6308
- Van Royen, 2005, Osteoid osteoma of the spine: a novel technique using combined computer-assisted and gamma probe-guided high-speed intralesional drill excision, Spine, 30, 369, 10.1097/01.brs.0000152531.49095.34 · doi:10.1097/01.brs.0000152531.49095.34
- Smitherman, 2010, Image-guided multilevel vertebral osteotomies for en bloc resection of giant cell tumor of the thoracic spine: case report and description of operative technique, Eur Spine J, 19, 1021, 10.1007/s00586-009-1273-5 · doi:10.1007/s00586-009-1273-5
- Reid, 1978, Ultrasonic visualization of a cervical cord cystic astrocytoma, AJR Am J Roentgenol, 131, 907, 10.2214/ajr.131.5.907 · doi:10.2214/ajr.131.5.907
- Epstein, 1991, Intraoperative ultrasonography: an important surgical adjunct for intramedullary tumors, J Neurosurg, 74, 729, 10.3171/jns.1991.74.5.0729 · doi:10.3171/jns.1991.74.5.0729
- Regelsberger, 2005, Intraoperative sonography of intra- and extramedullary tumors, Ultrasound Med Biol, 31, 593, 10.1016/j.ultrasmedbio.2005.01.016 · doi:10.1016/j.ultrasmedbio.2005.01.016
- Bozinov, 2012, Intra-operative high frequency ultrasound improves surgery of intramedullary cavernous malformations, Neurosurg Rev, 35, 269, 10.1007/s10143-011-0364-z · doi:10.1007/s10143-011-0364-z
- Friedman, 2000, Migration of an intraspinal schwannoma documented by intraoperative ultrasound: case report, Surg Neurol, 54, 455, 10.1016/S0090-3019(00)00314-1 · doi:10.1016/s0090-3019(00)00314-1
- Kolstad, 2006, Three-dimensional ultrasonography navigation in spinal cord tumor surgery. Technical note, J Neurosurg Spine, 5, 264, 10.3171/spi.2006.5.3.264 · doi:10.3171/spi.2006.5.3.264
- Maiuri, 1997, The role of intraoperative sonography in reducing invasiveness during surgery for spinal tumors, Minim Invasive Neurosurg, 40, 8, 10.1055/s-2008-1053405 · doi:10.1055/s-2008-1053405
- Maiuri, 2000, Intraoperative sonography for spinal tumors. Correlations with MR findings and surgery, J Neurosurg Sci, 44, 115
- Zhou, 2011, Intraoperative ultrasound assistance in treatment of intradural spinal tumours, Clin Neurol Neurosurg, 113, 531, 10.1016/j.clineuro.2011.03.006 · doi:10.1016/j.clineuro.2011.03.006
- Prada, 2014, Intraoperative ultrasound in spinal tumor surgery, J Ultrasound, 17, 195, 10.1007/s40477-014-0102-9 · doi:10.1007/s40477-014-0102-9
- D’Andrea, 2015, Utility of preoperative magnetic resonance imaging coregistered with intraoperative computed tomographic scan for the resection of complex tumors of the spine, World Neurosurg, 84, 1804, 10.1016/j.wneu.2015.07.072 · doi:10.1016/j.wneu.2015.07.072
- Leksell, 1985, Stereotaxis and nuclear magnetic resonance. A technical note, J Neurol Neurosurg Psychiatry, 48, 14, 10.1136/jnnp.48.1.14 · doi:10.1136/jnnp.48.1.14
- Cohen, 1995, Effects of coregistration of MR to CT images on MR stereotactic accuracy, J Neurosurg, 82, 772, 10.3171/jns.1995.82.5.0772 · doi:10.3171/jns.1995.82.5.0772
- Bradford, 1987, MRI-directed stereotactic biopsy of cerebral lesions, Acta Neurochir, 39, 25
- Lévesque, 1990, Stereotactic investigation of limbic epilepsy using a multimodal image analysis system. Technical note, J Neurosurg, 73, 792, 10.3171/jns.1990.73.5.0792 · doi:10.3171/jns.1990.73.5.0792
- Kamogawa, 2009, The 3D-MRI/MRA/CT Fusion Imaging in spine and spinal cord disorders focusing on upper cervical spine: report of two cases, Spine Spinal Cord, 22, 979
- Kamagoawa, 2015, Virtual pathology of cervical radiculopathy based on 3D MR/CT fusion images: impingement, flattening or twisted condition of the compressed nerve root in three cases, Springerplus, 4, 123, 10.1186/s40064-015-0898-6 · doi:10.1186/s40064-015-0898-6
- Castro, 1996, Accuracy of pedicle screw placement in lumbar vertebrae, Spine, 21, 1320, 10.1097/00007632-199606010-00008 · doi:10.1097/00007632-199606010-00008
- Laine, 1997, Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients, Eur Spine J, 6, 402, 10.1007/BF01834068 · doi:10.1007/bf01834068
- Wiesner, 2000, Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine, Spine, 25, 615, 10.1097/00007632-200003010-00013 · doi:10.1097/00007632-200003010-00013
- Seichi, 2005, Revision cervical spine surgery using transarticular or pedicle screws under a computer-assisted imageguidance system, J Orthop Sci, 10, 385, 10.1007/s00776-005-0902-z · doi:10.1007/s00776-005-0902-z
- Jones, 1997, Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison, Spine, 22, 977, 10.1097/00007632-199705010-00009 · doi:10.1097/00007632-199705010-00009
- Kotani, 1994, Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine, Spine, 19, 2529, 10.1097/00007632-199411001-00007 · doi:10.1097/00007632-199411001-00007
- Allam, 2013, Computer tomography assessment of pedicle screw placement in thoracic spine: comparison between free hand and a generic 3D-based navigation techniques, Eur Spine J, 22, 648, 10.1007/s00586-012-2505-7 · doi:10.1007/s00586-012-2505-7
- Luther, 2015, Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: Screw accuracy, screw size, and the complexity of surgery, J Spinal Disord Tech, 28, E298, 10.1097/BSD.0b013e31828af33e · doi:10.1097/bsd.0b013e31828af33e
- Theocharopoulos, 2003, Occupational exposure from common fluoroscopic projections used in orthopaedic surgery, J Bone Joint Surg Am, 85, 1698, 10.2106/00004623-200309000-00007 · doi:10.2106/00004623-200309000-00007
- Mroz, 2011, Radiation exposure to the surgeon during percutaneous pedicle screw placement, J Spinal Disord Tech, 24, 264, 10.1097/BSD.0b013e3181eed618 · doi:10.1097/bsd.0b013e3181eed618
- Rampersaud, 2000, Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion, Spine, 25, 2637, 10.1097/00007632-200010150-00016 · doi:10.1097/00007632-200010150-00016
- Bindal, 2008, Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion, J Neurosurg Spine, 9, 570, 10.3171/SPI.2008.4.08182 · doi:10.3171/spi.2008.4.08182
- Taher, 2013, 2013 Young Investigator Award winner: how safe is lateral lumbar interbody fusion for the surgeon? A prospective in vivo radiation exposure study, Spine, 38, 1386, 10.1097/BRS.0b013e31828705ad · doi:10.1097/brs.0b013e31828705ad
- Kim, 2008, Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery, Spine J, 8, 584, 10.1016/j.spinee.2006.12.012 · doi:10.1016/j.spinee.2006.12.012
- Kraus, 2010, Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?, Clin Orthop Relat Res, 468, 2419, 10.1007/s11999-010-1393-6 · doi:10.1007/s11999-010-1393-6
- Lieberman, 2006, Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part I–Technical development and a test case result, Neurosurgery, 59, 641, 10.1227/01.NEU.0000229055.00829.5B · doi:10.1227/01.neu.0000229055.00829.5b
- Togawa, 2007, Bone-mounted miniature robotic guidance for pedicle screw and translaminar facet screw placement: part 2–Evaluation of system accuracy, Neurosurgery, 60, ONS129
- Roser, 2013, Maier G Spinal robotics: current applications and future perspectives, Neurosurgery, 72, 12, 10.1227/NEU.0b013e318270d02c · doi:10.1227/neu.0b013e318270d02c
- Schizas, 2012, Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy, Acta Orthop Belg, 78, 240
- Kantelhardt, 2011, Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement, Eur Spine J, 20, 860, 10.1007/s00586-011-1729-2 · doi:10.1007/s00586-011-1729-2
- Lonjon, 2016, Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis, Eur Spine J, 25, 947, 10.1007/s00586-015-3758-8 · doi:10.1007/s00586-015-3758-8
- Obenchain, 1991, Laparoscopic lumbar discectomy: case report, J Laparoendosc Surg, 1, 145, 10.1089/lps.1991.1.145 · doi:10.1089/lps.1991.1.145
- Inamasu, 2005, Laparoscopic anterior lumbar interbody fusion: a review of outcome studies, Minim Invasive Neurosurg, 48, 340, 10.1055/s-2005-915634 · doi:10.1055/s-2005-915634
- Liu, 2002, Is laparoscopic anterior lumbar interbody fusion a useful minimally invasive procedure?, Neurosurgery, 51, S155, 10.1097/00006123-200211002-00021 · doi:10.1097/00006123-200211002-00021
- Chung, 2003, Comparative study of laparoscopic L5-S1 fusion versus open mini-ALIF, with a minimum 2-year follow-up, Eur Spine J, 12, 613, 10.1007/s00586-003-0526-y · doi:10.1007/s00586-003-0526-y
- Lee, 2013, Technique and surgical outcomes of robot-assisted anterior lumbar interbody fusion, J Robot Surg, 7, 177, 10.1007/s11701-012-0365-0 · doi:10.1007/s11701-012-0365-0
- Lee, 2013, Minimally invasive, robot-assisted, anterior lumbar interbody fusion: a technical note, J Neurol Surg A Cent Eur Neurosurg, 74, 258, 10.1055/s-0032-1330121 · doi:10.1055/s-0032-1330121
- Yang, 2011, Robot-assisted anterior lumbar interbody fusion in a Swine model in vivo test of the da vinci surgical-assisted spinal surgery system, Spine, 36, E139, 10.1097/BRS.0b013e3181d40ba3 · doi:10.1097/brs.0b013e3181d40ba3
Cited by
Artificial Intelligence in Medicine: Today and Tomorrow
Briganti, G., & Le Moine, O. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00027 · Cited by 743
Telerobotic Spinal Surgery Based on 5G Network: The First 12 Cases
Tian, W., Fan, M., Zeng, C., Liu, Y., He, D., & Zhang, Q. (2020) · Neurospine · doi:10.14245/ns.1938454.227 · Cited by 255
Deep Learning-Based X-ray Inpainting for Improving Spinal 2d-3d Registration
Esfandiari, H., Weidert, S., Kövesházi, I., Anglin, C., Street, J., & Hodgson, A. J. (2021) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.2228 · Cited by 12
Metadata
- Authors
- Overley, S. C., Cho, S. K., Mehta, A. I., & Arnold, P. M.
- Venue
- Neurosurgery
- Published
- 2017-02-21
- Volume
- 80
- Issue
- 3S
- Pages
- S86-S99
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2590852980
- Cited by
- 327
- References
- 25
- FWCI
- 25.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Navigation and Robotics in Spinal Surgery: Where Are We Now? https://app.cochat.ai/papers/10.1093/neuros/nyw077
- The paper
- Overley, S. C., Cho, S. K., Mehta, A. I., & Arnold, P. M. (2017). Navigation and Robotics in Spinal Surgery: Where Are We Now? Neurosurgery. https://doi.org/10.1093/neuros/nyw077
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.