Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 245

The DOI matches its Crossref record.

Laparoscopic Fusion of the Lumbar Spine: Minimally Invasive Spine Surgery: A Prospective Multicenter Study Evaluating Open and Laparoscopic Lumbar Fusion

Regan, John J., Yuan, Hansen, McAfee, Paul C. · 1999 · Spine

Abstract

STUDY DESIGN: Two hundred-forty consecutive patients underwent laparoscopic instrumented interbody fusion using custom-designed instrumentation and BAK (Sulzer Spine Tech, Minneapolis, MN) fusion cages. The surgeries were performed at eight spine centers during U.S. Food and Drug Administration investigational device evaluation clinical trials. This cohort was compared with 591 consecutive patients undergoing open anterior fusion with the same device. OBJECTIVES: To investigate the feasibility and safety of the laparoscopic approach compared with that of open procedures. SUMMARY OF BACKGROUND DATA: In other areas of medicine, advances in laparoscopic surgical procedures have resulted in reduced morbidity, expense, and pain when compared with results of the open counterpart. METHODS: The open anterior procedure was performed using a retroperitoneal approach. The laparoscopic procedure was performed transperitoneally with carbon dioxide insufflation to provide visualization using a 10-mm endoscope. Two hollow, titanium, threaded interbody implants packed with autologous bone were inserted into the diseased interspace. RESULTS: The laparoscopy group had a shorter hospital stay and reduced blood loss but had increased operative time. Operative time improved in the laparoscopy group as surgeons' experience increased. Operative complications were comparable in both groups, with an occurrence of 4.2% in the open approach and 4.9% in the laparoscopic approach. Overall, the device-related reoperation rate was higher in the laparoscopy group (4.7% vs. 2.3%), primarily as a result of intraoperative disc herniation. Conversion to open procedure in the laparoscopy group was 10%, with most cases predictable and preventable. CONCLUSIONS: The laparoscopic procedure is associated with a learning curve, but once mastered, it is effective and safe when compared with open techniques of fusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-199902150-00023

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 245

Metadata

Authors
Regan, J. J., Yuan, H., & McAfee, P. C.
Venue
Spine
Published
1999-02
Volume
24
Issue
4
Pages
402-411
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2333148506
Cited by
245
References
0
FWCI
10.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laparoscopic Fusion of the Lumbar Spine: Minimally Invasive Spine Surgery: A Prospective Multicenter Study Evaluating Open and Laparoscopic Lumbar Fusion. https://app.cochat.ai/papers/10.1097/00007632-199902150-00023
The paper
Regan, J. J., Yuan, H., & McAfee, P. C. (1999). Laparoscopic Fusion of the Lumbar Spine: Minimally Invasive Spine Surgery: A Prospective Multicenter Study Evaluating Open and Laparoscopic Lumbar Fusion. Spine. https://doi.org/10.1097/00007632-199902150-00023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.