Laparoscopic Fusion of the Lumbar Spine: Minimally Invasive Spine Surgery: A Prospective Multicenter Study Evaluating Open and Laparoscopic Lumbar Fusion
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: Two hundred-forty consecutive patients underwent laparoscopic instrumented interbody fusion using custom-designed instrumentation and BAK (Sulzer Spine Tech, Minneapolis, MN) fusion cages. The surgeries were performed at eight spine centers during U.S. Food and Drug Administration investigational device evaluation clinical trials. This cohort was compared with 591 consecutive patients undergoing open anterior fusion with the same device. OBJECTIVES: To investigate the feasibility and safety of the laparoscopic approach compared with that of open procedures. SUMMARY OF BACKGROUND DATA: In other areas of medicine, advances in laparoscopic surgical procedures have resulted in reduced morbidity, expense, and pain when compared with results of the open counterpart. METHODS: The open anterior procedure was performed using a retroperitoneal approach. The laparoscopic procedure was performed transperitoneally with carbon dioxide insufflation to provide visualization using a 10-mm endoscope. Two hollow, titanium, threaded interbody implants packed with autologous bone were inserted into the diseased interspace. RESULTS: The laparoscopy group had a shorter hospital stay and reduced blood loss but had increased operative time. Operative time improved in the laparoscopy group as surgeons' experience increased. Operative complications were comparable in both groups, with an occurrence of 4.2% in the open approach and 4.9% in the laparoscopic approach. Overall, the device-related reoperation rate was higher in the laparoscopy group (4.7% vs. 2.3%), primarily as a result of intraoperative disc herniation. Conversion to open procedure in the laparoscopy group was 10%, with most cases predictable and preventable. CONCLUSIONS: The laparoscopic procedure is associated with a learning curve, but once mastered, it is effective and safe when compared with open techniques of fusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boden, S. D., McCowin, P. R., Davis, D. O., Dina, T. S., Mark, A. S., & Wiesel, S. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072080-00008 · Cited by 2,708
Boden, S. D., Davis, D. O., Dina, T. S., Patronas, N. J., & Wiesel, S. W. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072030-00013 · Cited by 2,115
Arthrodesis by the Distraction-Compression Method Using a Stainless Steel Implant
Bagby, G. W. (1988) · Orthopedics · doi:10.3928/0147-7447-19880601-13 · Cited by 369
Disc degeneration. Its frequency and relationship to symptoms.
Lawrence, J. S. (1969) · Annals of the Rheumatic Diseases · doi:10.1136/ard.28.2.121 · Cited by 316
Anterior fusion of the lumbar spine. End-result study with long-term follow-up.
FLYNN, J. C., & Hoque, M. A. (1979) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197961080-00002 · Cited by 159
Cited by
Gittens, R. A., Olivares-Navarrete, R., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.037 · Cited by 447
Statistical assessment of the learning curves of health technologies
Ramsay, C. R., Grant, A. M., Wallace, S. A., Garthwaite, P. H., Monk, A. F., & Russell, I. T. (2001) · Health Technology Assessment · doi:10.3310/hta5120 · Cited by 353
Current Concepts Review - Interbody Fusion Cages in Reconstructive Operations on the Spine*
MCAFEE, P. C. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199906000-00014 · Cited by 306
Self-citationSaal, J. A., & Saal, J. S. (2000) · Spine · doi:10.1097/00007632-200010150-00013 · Cited by 301
Sclafani, J. A., & Kim, C. W. (2014) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-014-3495-z · Cited by 237
Vascular injury and complication in neurosurgical spine surgery
Inamasu, J., & Guiot, B. H. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-005-0669-1 · Cited by 225
“Several prospective studies comparing the complication rates between ALIF and posterior lumbar fusion surgery found that ALIF actually had a higher risk of developing DVT, although the figure did not reach statistical significance [32, 103].”
InfluentialAnalysis of Operative Complications in a Series of 471 Anterior Lumbar Interbody Fusion Procedures
Sasso, R. C., Best, N. M., Mummaneni, P. V., Reilly, T. M., & Hussain, S. M. (2005) · Spine · doi:10.1097/01.brs.0000155423.18218.75 · Cited by 193
“Severe vascular damage has been reported previously with the use of such tools that exert large amounts of force on the endplate and may slip out of position.(8,27,30,31) Of specific concern is the L4–L5 disc space, which is typically more difficult to expose because of the position of the iliac bifurcation and tether…”
BackgroundKaiser, M. G., Haid, R. W., Subach, B. R., Miller, J. S., Smith, C. D., & Rodts, G. E. (2002) · Neurosurgery · doi:10.1097/00006123-200207000-00015 · Cited by 175
Minimally invasive versus open transforaminal lumbar interbody fusion
Burneikiene, S., Roeca, C., Nelson, L., Mason, A., & Villavicencio, A. (2010) · Surgical Neurology International · doi:10.4103/2152-7806.63905 · Cited by 175
Saal, J. A., & Saal, J. S. (2002) · Spine · doi:10.1097/00007632-200205010-00017 · Cited by 170
van Dijk, M., Smit, T. H., Sugihara, S., Burger, E. H., & Wuisman, P. I. (2002) · Spine · doi:10.1097/00007632-200204010-00003 · Cited by 165
“These complications still present a problem in lumbar interbody fusion.(7,15,19,24,25,31,33) To explore the potential benefits of a bioabsorbable cage with less stiffness than current cage devices, poly(L-lactic acid) (PLLA) cages have been designed with a modulus having an elasticity of 4.”
BackgroundIn vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
van Dijk, M., Tunc, D. C., Smit, T. H., Higham, P., Burger, E. H., & Wuisman, P. I. J. M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10466 · Cited by 78
Metadata
- Authors
- Regan, J. J., Yuan, H., & McAfee, P. C.
- Venue
- Spine
- Published
- 1999-02
- Volume
- 24
- Issue
- 4
- Pages
- 402-411
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2333148506
- Cited by
- 245
- References
- 5
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.