Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After Vertebroplasty
Abstract
STUDY DESIGN: The biomechanical behavior of a single lumbar vertebral body after various surgical treatments with acrylic vertebroplasty was parametrically studied using finite-element analysis. OBJECTIVES: To provide a theoretical framework for understanding and optimizing the biomechanics of vertebroplasty. Specifically, to investigate the effects of volume and distribution of bone cement on stiffness recovery of the vertebral body. SUMMARY OF BACKGROUND DATA: Vertebroplasty is a treatment that stabilizes a fractured vertebra by addition of bone cement. However, there is currently no information available on the optimal volume and distribution of the filler material in terms of stiffness recovery of the damaged vertebral body. METHODS: An experimentally calibrated, anatomically accurate finite-element model of an elderly L1 vertebral body was developed. Damage was simulated in each element based on empirical measurements in response to a uniform compressive load. After virtual vertebroplasty (bone cement filling range of 1-7 cm3) on the damaged model, the resulting compressive stiffness of the vertebral body was computed for various spatial distributions of the filling material and different loading conditions. RESULTS: Vertebral stiffness recovery after vertebroplasty was strongly influenced by the volume fraction of the implanted cement. Only a small amount of bone cement (14% fill or 3.5 cm3) was necessary to restore stiffness of the damaged vertebral body to the predamaged value. Use of a 30% fill increased stiffness by more than 50% compared with the predamaged value. Whereas the unipedicular distributions exhibited a comparative stiffness to the bipedicular or posterolateral cases, it showed a medial-lateral bending motion ("toggle") toward the untreated side when a uniform compressive pressure load was applied. CONCLUSION: Only a small amount of bone cement ( approximately 15% volume fraction) is needed to restore stiffness to predamage levels, and greater filling can result in substantial increase in stiffness well beyond the intact level. Such overfilling also renders the system more sensitive to the placement of the cement because asymmetric distributions with large fills can promote single-sided load transfer and thus toggle. These results suggest that large fill volumes may not be the most biomechanically optimal configuration, and an improvement might be achieved by use of lower cement volume with symmetric placement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
Ulrich, D., van Rietbergen, B., Laib, A., & R̈uegsegger, P. (1999) · Bone · doi:10.1016/s8756-3282(99)00098-8 · Cited by 718
Yield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653
Self-citationFatigue Behavior of Adult Cortical Bone: The Influence of Mean Strain and Strain Range
Carter, D. R., Caler, W. E., Spengler, D. M., & Frankel, V. H. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108992136 · Cited by 368
Fatigue fracture of human lumbar vertebrae
Brinckmann, P., Biggemann, M., & Hilweg, D. (1988) · Clinical Biomechanics · doi:10.1016/s0268-0033(88)80001-9 · Cited by 299
Biomechanics of Fracture Risk Prediction of the Hip and Spine by Quantitative Computed Tomography
Hayes, W. C., Piazza, S. J., & Zysset, P. K. (1991) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)02675-6 · Cited by 259
Biologically meaningful determinants of the in vitro strength of lumbar vertebrae
Vesterby, A., Mosekilde, L., Gundersen, H. J. G., Melsen, F., Mosekilde, L., Holme, K., & Sørensen, S. (1991) · Bone · doi:10.1016/8756-3282(91)90044-j · Cited by 233
Silva, M. J., Wang, C., Keaveny, T. M., & Hayes, W. C. (1994) · Bone · doi:10.1016/8756-3282(94)90817-6 · Cited by 210
Self-citationPanjabi, M. M., Krag, M. H., & Goel, V. K. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90095-6 · Cited by 156
Mechanical behavior of human trabecular bone after overloading
Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170308 · Cited by 155
Self-citationAge-related differences in post-yield damage in human cortical bone. Experiment and model
Courtney, A. C., Hayes, W. C., & Gibson, L. J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)84542-8 · Cited by 131
Cited by
Crawford, R. P., Cann, C. E., & Keaveny, T. M. (2003) · Bone · doi:10.1016/s8756-3282(03)00210-2 · Cited by 547
Self-citationKopperdahl, D. L., Morgan, E. F., & Keaveny, T. M. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00185-1 · Cited by 267
Self-citation
Metadata
- Authors
- Liebschner, M. A. K., Rosenberg, W. S., & Keaveny, T. M.
- Venue
- Spine
- Published
- 2001-07
- Volume
- 26
- Issue
- 14
- Pages
- 1547-1554
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2044559502
- Cited by
- 470
- References
- 12
- FWCI
- 15.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After Vertebroplasty. https://app.cochat.ai/papers/10.1097/00007632-200107150-00009
- The paper
- Liebschner, M. A. K., Rosenberg, W. S., & Keaveny, T. M. (2001). Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After Vertebroplasty. Spine. https://doi.org/10.1097/00007632-200107150-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.