Body composition at the bedside
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate the use of an inexpensive hand-held bioelectric impedance analysis machine which measures lean body mass, by technical comparisons against standard instruments and techniques (an in-house bioelectric impedance machine and dual energy X-ray absorptiometry), and by performing body composition analyses in groups of potentially malnourished patients. DESIGN: Prospective simultaneous comparison of measurements made by the hand-held and in-house bioelectric analysis machines and dual energy x-ray absorptiometry. SETTING: Medical Physics Department and Gastrointestinal Unit in a university teaching hospital. SUBJECTS/METHODS: One hundred and sixty subjects were recruited into the study. Data from 58 adolescent and 14 adult volunteers and from 42 adult patients were used for technical comparisons (n = 114). Body composition information was evaluated (n = 102) for 60 adult volunteers and 42 patients (17 with eating disorders, 7 with chronic alcoholic pancreatitis and 18 with inflammatory bowel disease). OUTCOME MEASURES: Estimation of bias, limits of agreement and correlations on data from the three machines. Relationships between percentage body mass as lean, absolute weights and body mass index, in the adult subjects. RESULTS: Both resistance and calculated impedance measured by the hand-held machine significantly correlated with the impedance measured by the in-house machine (r = 0.996; P < 0.0001). An estimation of the level of agreement in percentage lean measurement between dual energy x-ray absorptiometry and hand-held bioelectrical impedance analysis machine by the Bland and Altman method showed a bias of -0.07% and satisfactory limits of agreement from -7.97% to 7.76%. Body mass index was similar in the groups of healthy men and women, but proportion of weight as lean was significantly higher in men than women. In underweight patients with eating disorders, the ratio of lean to fat varied widely; in inflammatory bowel disease patients, proportions of lean and fat were similar to controls; however patients with alcoholic pancreatitis had values for body mass index similar to controls, but had significantly lower proportion of their body weight as lean (P < 0.05). CONCLUSION: In non-obese and thin adults, an accurate two-compartment (lean, fat) measurement of body composition can be made in 10 min by using an inexpensive, hand-held, bioelectric impedance analysis machine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“Many of the whole body bioimpedance instruments apply three approaches for impedance measurement: hand to foot method [14,17], foot to foot [44–46] method and hand to hand method [47,48].”
MethodElectrical impedance spectroscopy (EIS) for biological analysis and food characterization: a review
Grossi, M., & Riccò, B. (2017) · Journal of Sensors and Sensor Systems · doi:10.5194/jsss-6-303-2017 · Cited by 394
Meeuwsen, S., Horgan, G. W., & Elia, M. (2010) · Clinical Nutrition · doi:10.1016/j.clnu.2009.12.011 · Cited by 275
Metabolically healthy obesity: different prevalences using different criteria
Velho, S., Paccaud, F., Waeber, G., Vollenweider, P., & Marques-Vidal, P. (2010) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2010.114 · Cited by 249
“This device has been validated against reference methods (Ghosh et al., 1997) and its results have been shown to be more accurate than those obtained using a dual frequency bioelectrical impedance analysis device (Simpson et al.”
MethodAerobic fitness is associated with lower proportions of senescent blood T-cells in man
Spielmann, G., McFarlin, B. K., O’Connor, D. P., Smith, P. J. W., Pircher, H., & Simpson, R. J. (2011) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2011.07.226 · Cited by 180
Metadata
- Authors
- Ghosh, S., Meister, D., Cowen, S., Hannan, J. W., & Ferguson, A.
- Venue
- European Journal of Gastroenterology & Hepatology
- Published
- 1997-08
- Volume
- 9
- Issue
- 8
- Pages
- 783-788
- ISSN
- 0954-691X (ISSN-L)
- OpenAlex
- W2079120933
- Cited by
- 43
- References
- 0
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Body composition at the bedside. https://app.cochat.ai/papers/10.1097/00042737-199708000-00009
- The paper
- Ghosh, S., Meister, D., Cowen, S., Hannan, J. W., & Ferguson, A. (1997). Body composition at the bedside. European Journal of Gastroenterology & Hepatology. https://doi.org/10.1097/00042737-199708000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.