The DOI matches its Crossref record.
24-Hour Monitoring of Intraocular Pressure in Glaucoma Management: A Retrospective Review
Abstract
Purpose Diurnal variation in intraocular pressure (IOP) is well recognized, yet important decisions in glaucoma management are frequently made after 1 or 2 IOP measurements. Twenty-four-hour monitoring of IOP may identify IOP variation and spikes. This study determined the value of 24-hour IOP monitoring in routine clinical practice. Methods Data were acquired retrospectively from case notes of 29 glaucoma patients sequentially admitted for 24-hour IOP monitoring while taking their established antiglaucoma therapy. Results While there was no difference between the mean clinic (office) and mean 24-hour IOP measurements, the peak IOP during 24-hour monitoring was on average 4.9 mm Hg higher than the peak clinic IOP (P <0.0001). In 4 (13.8%) patients, the peak IOP over 24 hours was at least 12 mm Hg higher than the clinic peak. Peak IOP values occurred outside normal office hours in 51.7% of patients. Twenty-four-hour IOP monitoring resulted in a change of clinical management in 23 (79.3%) patients, including 13 (44.8%) who were offered trabeculectomy. Conclusion Twenty-four-hour monitoring of IOP frequently led to a change of glaucoma management by identifying IOP fluctuations and spikes. High IOP and wide diurnal IOP variation are considered major risk factors for glaucoma progression, and standard clinic follow-up evaluations failed to identify these phenomena.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2049825 · Cited by 264
Ocular perfusion pressure in glaucoma
Costa, V. P., Harris, A., Anderson, D., Stodtmeister, R., Cremasco, F., Kergoat, H., Lovasik, J., Stalmans, I., Zeitz, O., Lanzl, I., et al. (2014) · Acta Ophthalmologica · doi:10.1111/aos.12298 · Cited by 255
Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
Chen, G.-Z., Chan, I.-S., & Lam, D. C. C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.08.029 · Cited by 133
Metadata
- Authors
- Hughes, E., Spry, P., & Diamond, J.
- Venue
- Journal of Glaucoma
- Published
- 2003-06
- Volume
- 12
- Issue
- 3
- Pages
- 232-236
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W4237700722
- Cited by
- 241
- References
- 0
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 24-Hour Monitoring of Intraocular Pressure in Glaucoma Management: A Retrospective Review. https://app.cochat.ai/papers/10.1097/00061198-200306000-00009
- The paper
- Hughes, E., Spry, P., & Diamond, J. (2003). 24-Hour Monitoring of Intraocular Pressure in Glaucoma Management: A Retrospective Review. Journal of Glaucoma. https://doi.org/10.1097/00061198-200306000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.