Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. DESIGN: Raw pulse wave and cuff pressure data were stored electronically using embedded software in the BPM-100(Beta), during the validation trial. The 391 sets of measurements were separated objectively into two subsets. A subset of 136 measurements was used to develop a new algorithm to enhance the accuracy of the device when reading higher systolic pressures. The larger subset of 255 measurements (three readings for 85 subjects) was used as test data to validate the accuracy of the new algorithm. METHODS: Differences between the new algorithm BPM-100 and the reference (mean of two observers) were determined and expressed as the mean difference +/- SD, plus the percentage of measurements within 5, 10, and 15 mmHg. RESULTS: The mean difference between the BPM-100 and reference systolic BP was -0.16 +/- 5.13 mmHg, with 73.7% < or = 5 mmHg, 94.9% < or = 10 mmHg and 98.8% < or = 15 mmHg. The mean difference between the BPM-100 and reference diastolic BP was -1.41 +/- 4.67 mmHg, with 78.4% < or = 5 mmHg, 92.5% < or = 10 mmHg, and 99.2% < or = 15 mmHg. These data improve upon that of the BPM-100(Beta) and pass the AAMI standard, and 'A' grade BHS protocol. CONCLUSION: This study illustrates a new method for developing and testing a change in an algorithm for an oscillometric BP monitor utilizing collected and stored electronic data and demonstrates that the new algorithm meets the AAMI standard and BHS protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Quinn, R. R., Hemmelgarn, B. R., Padwal, R. S., Myers, M. G., Cloutier, L., Bolli, P., McKay, D. W., Khan, N. A., Hill, M. D., Mahon, J., et al. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70378-0 · Cited by 346
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., Grant, F. C., & Kaczorowski, J. (2011) · BMJ · doi:10.1136/bmj.d286 · Cited by 285
Daskalopoulou, S. S., Khan, N. A., Quinn, R. R., Ruzicka, M., McKay, D. W., Hackam, D. G., Rabkin, S. W., Rabi, D. M., Gilbert, R. E., Padwal, R. S., et al. (2012) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2012.02.018 · Cited by 266
Results of the Ontario Survey on the Prevalence and Control of Hypertension
Leenen, F. H. H., Dumais, J., McInnis, N. H., Turton, P., Stratychuk, L., Nemeth, K., Moy Lum-Kwong, M., & Fodor, G. (2008) · Canadian Medical Association Journal · doi:10.1503/cmaj.071340 · Cited by 248
Tavakoly Sany, S. B., Behzhad, F., Ferns, G., & Peyman, N. (2020) · BMC Health Services Research · doi:10.1186/s12913-020-4901-8 · Cited by 231
Use of automated office blood pressure measurement to reduce the white coat response
Myers, M. G., Valdivieso, M., & Kiss, A. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32831b9e6b · Cited by 209
“Two devices designed for professional use, the BpTRU [ 5 ] and the Omron HEM 907 [6], have been used by health professionals to obtain BP readings in the office with minimal patient‐ observer interaction, thus reducing the white coat response.”
MethodProvider communication effects medication adherence in hypertensive African Americans
Schoenthaler, A., Chaplin, W. F., Allegrante, J. P., Fernandez, S., Diaz-Gloster, M., Tobin, J. N., & Ogedegbe, G. (2009) · Patient Education and Counseling · doi:10.1016/j.pec.2008.09.018 · Cited by 191
“The BP readings at the consent visit were taken by trained Research Assistants (RA) using a validated automated blood pressure monitor BPTru device (Snoqualmie, WA, USA) [18].”
MethodBeckett, L., & Godwin, M. (2005) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-5-18 · Cited by 175
“The BpTRU device uses the oscillometric technique used by most ambulatory and home blood pressure measuring devices [19,20].”
Schwartz, J. E., Muntner, P., Kronish, I. M., Burg, M. M., Pickering, T. G., Bigger, J. T., & Shimbo, D. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.10.039 · Cited by 108
Prevalence of pseudoresistant hypertension due to inaccurate blood pressure measurement
Bhatt, H., Siddiqui, M., Judd, E., Oparil, S., & Calhoun, D. (2016) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2016.03.186 · Cited by 77
Stergiou, G. S., Lourida, P., Tzamouranis, D., & Baibas, N. M. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.20 · Cited by 74
Boutin-Foster, C., Offidani, E., Kanna, B., Ogedegbe, G., Ravenell, J., Scott, E., Rodriguez, A., Ramos, R., Michelen, W., Gerber, L. M., et al. (2016) · Ethnicity & Disease · doi:10.18865/ed.26.1.51 · Cited by 41
Stergiou, G. S., Lourida, P., & Tzamouranis, D. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2010.107 · Cited by 18
Comparability of two commonly used automated office blood pressure devices in the severely obese
Padwal, R. S., & Majumdar, S. R. (2016) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000196 · Cited by 9
Metadata
- Authors
- Wright, J. M., Mattu, G. S., Perry, T. L., Gelferc, M. E., Strange, K. D., Zorn, A., & Chen, Y.
- Venue
- Blood Pressure Monitoring
- Published
- 2001-06
- Volume
- 6
- Issue
- 3
- Pages
- 161-165
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2162576402
- Cited by
- 115
- References
- 1
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.