CoChat

Reproducibility of home and ambulatory blood pressure in children and adolescents

Stergiou, George S., Alamara, Christina V., Salgami, Eleanna V., Vaindirlis, Iraklis N., Dacou-Voutetakis, Catherine, Mountokalakis, Theodore D. · 2005 · Blood Pressure Monitoring
Cited by 96

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To evaluate the reproducibility of blood pressure measured at home (HBP) in comparison with ambulatory (ABP) and clinic blood pressure (CBP) in children and adolescents. PARTICIPANTS AND METHODS: Individuals aged 8-17 years who had been referred for elevated CBP were included. CBP was measured at two visits, HBP on 5 days and ABP for 24 h. A second session including all the above measurements was performed after 8 weeks. The reproducibility of CBP (second visit of each session), HBP (average of days 2-5 of each session) and ABP (average 24-h, awake and asleep) was quantified using test-retest correlations coefficients (r) and the standard deviation of differences (SDD) between repeated measurements. RESULTS: Sixteen individuals were included [mean age 13.3+/-2.9 (SD)] years, range 8-17, nine boys]. According to Task Force CBP criteria, eight were classified as hypertensives, three as high normal and five as normotensives. The reproducibility of HBP (systolic/diastolic r, 0.74/0.82, SDD 7.0/4.3) was superior to that of CBP (r, 0.63/0.80, SDD 10.4/6.3). However, ABP appeared to provide the most reproducible values (r, 0.87/0.84, SDD 5.5/4.3 for 24-h ABP; r, 0.85/0.76, SDD 5.9/5.0 for awake; r, 0.76/0.79, SDD 7.0/5.0 for asleep ABP). Aspects of the diurnal ABP variation were poorly reproducible (r, 0.62/0.14, SDD 6.8/5.5 for awake-asleep ABP difference; r, 0.55/0.26, SDD 0.07/0.11 for awake : asleep ratio). CONCLUSION: These data suggest that in children and adolescents home blood pressure measurements are more reproducible than clinic measurements. However, 24-h ambulatory monitoring appears to provide the most reproducible blood pressure values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200506000-00005

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 96

Metadata

Authors
Stergiou, G. S., Alamara, C. V., Salgami, E. V., Vaindirlis, I. N., Dacou-Voutetakis, C., & Mountokalakis, T. D.
Venue
Blood Pressure Monitoring
Published
2005-06
Volume
10
Issue
3
Pages
143-147
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2017962270
Cited by
96
References
2
FWCI
4.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of home and ambulatory blood pressure in children and adolescents. https://app.cochat.ai/papers/10.1097/00126097-200506000-00005
The paper
Stergiou, G. S., Alamara, C. V., Salgami, E. V., Vaindirlis, I. N., Dacou-Voutetakis, C., & Mountokalakis, T. D. (2005). Reproducibility of home and ambulatory blood pressure in children and adolescents. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200506000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.