The Pitfalls of Laparoscopic Surgery: Challenges for Robotics and Telerobotic Surgery
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
After its debut in 1988, laparoscopic cholecystectomy rapidly became the standard of care for cholelithiasis, yet very few surgeons use minimally invasive techniques for other abdominal operations. Why do most surgeons continue to perform traditional open gastrointestinal operations? We believe that the answer to this question lies in the fact that advanced laparoscopic operations are difficult to learn, perform, and master. A number of inherent pitfalls of laparoscopy hinder the performance of these operations even after the surgeon has accumulated years of experience. These pitfalls include an unstable video camera platform, limited motion (degrees of freedom) of straight laparoscopic instruments, two-dimensional imaging, and poor ergonomics for the surgeon. Inexperienced or bored laparoscopic camera-holders move the camera frequently and rotate it away from the horizon. The long, straight laparoscopic instruments are limited in their motion by the fixation enforced by the abdominal wall trocars. Similarly, the standard two-dimensional video imaging used in most laparoscopic operations impedes the surgeon's depth perception, compounding the limitations of laparoscopic instruments. In addition, surgeons are forced to assume ergonomically awkward stances in performing many laparoscopic operations. These four factors hinder a surgeon's efforts to learn and to perform advanced laparoscopic operations, significantly lengthening the learning curve. The articles presented in this issue suggest that robotics and telerobotics offer solutions to these nagging pitfalls of laparoscopic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coelioscopic Cholecystectomy: Preliminary Report of 36 Cases
DUBOIS, F., ICARD, P., BERTHELOT, G., & LEVARD, H. (1990) · Annals of Surgery · doi:10.1097/00000658-199001000-00010 · Cited by 793
The first laparoscopic cholecystectomy.
Reynolds, W. (2001) · PubMed Central · Cited by 578
Port site metastases after laparoscopic colorectal surgery for cure of malignancy
Wexner, S. D., & Cohen, S. M. (1995) · Journal of British Surgery · doi:10.1002/bjs.1800820305 · Cited by 561
Minimally Invasive and Robotic Surgery
Mack, M. J. (2001) · JAMA · doi:10.1001/jama.285.5.568 · Cited by 545 · cited 1×
“, decreases their degree of freedom (42).”
Gallstones and Laparoscopic Cholecystectomy
Gollan, J. L. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500080066034 · Cited by 525
Defining a learning curve for laparoscopic colorectal resections
Schlachta, C. M., Mamazza, J., Seshadri, P. A., Cadeddu, M., Gregoire, R., & Poulin, E. C. (2001) · Diseases of the Colon & Rectum · doi:10.1007/bf02234296 · Cited by 422
Bennett, C. L. (1997) · Archives of Surgery · doi:10.1001/archsurg.1997.01430250043009 · Cited by 303
Surgical technology and the ergonomics of laparoscopic instruments
Berguer, R. (1998) · Surgical Endoscopy · doi:10.1007/s004649900705 · Cited by 209 · cited 1×
“In difficult procedures such as laparoscopic colectomy, this leads to surgeon fatigue (49).”
BackgroundAbdominal wall recurrence after laparoscopic colectomy for colon cancer.
Cirocco, W. C., Schwartzman, A., & Golub, R. W. (1994) · PubMed · Cited by 190
Could age be an indication for laparoscopic colectomy in colorectal cancer?
Delgado, S., Lacy, A. M., Valdecasas, J. C. G., Balagué, C., Pera, M., Salvador, L., Momblan, D. N. D. M., & Visa, J. (2000) · Surgical Endoscopy · doi:10.1007/s004649900004 · Cited by 120
Cited by
State of the Evidence on Simulation-Based Training for Laparoscopic Surgery: A Systematic Review
Zendejas, B., Brydges, R., Hamstra, S. J., & Cook, D. A. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e318288c40b · Cited by 388
Ergonomics in Surgery: A Review
Catanzarite, T., Tan-Kim, J., Whitcomb, E. L., & Menefee, S. (2018) · Female Pelvic Medicine & Reconstructive Surgery · doi:10.1097/spv.0000000000000456 · Cited by 239
Nwoye, C. I., Yu, T., Gonzalez, C., Seeliger, B., Mascagni, P., Mutter, D., Marescaux, J., & Padoy, N. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102433 · Cited by 207
“Yet, this success comes at a price for the surgeon, who now has to deal with increased technical di ffi culty coming from the indirect vision and laparoscopic instruments (Ballantyne, 2002), especially during complex cases (Felli et al., 2019).”
BackgroundMinimally invasive abdominal surgery: lux et veritas past, present, and future
Harrell, A. G., & Heniford, B. T. (2005) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2005.05.019 · Cited by 187
Halabi, W. J., Kang, C. Y., Jafari, M. D., Nguyen, V. Q., Carmichael, J. C., Mills, S., Stamos, M. J., & Pigazzi, A. (2013) · World Journal of Surgery · doi:10.1007/s00268-013-2024-7 · Cited by 177
“RACS addresses some of the technical limitations of CLS [22, 28].”
BackgroundFeasibility study of intraocular robotic surgery with the da Vinci surgical system
BOURLA, D. H., HUBSCHMAN, J. P., CULJAT, M., TSIRBAS, A., GUPTA, A., & SCHWARTZ, S. D. (2008) · Retina · doi:10.1097/iae.0b013e318068de46 · Cited by 106
Metadata
- Authors
- Ballantyne, G. H.
- Venue
- Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
- Published
- 2002-02
- Volume
- 12
- Issue
- 1
- Pages
- 1-5
- ISSN
- 1530-4515 (ISSN-L)
- OpenAlex
- W1979890740
- Cited by
- 176
- References
- 11
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.