Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Pulmonary artery occlusion pressure and central venous pressure have been considered to be reliable measures of left and right ventricular preload in patients requiring invasive hemodynamic monitoring. Studies in recent years have questioned the correlation between these estimates of ventricular filling pressures and ventricular end-diastolic volumes/cardiac performance variables in specific patient groups, but clinicians have continued to consider the relationship valid in the broader context. The objective of this study was to assess the relationship between pressure estimates of ventricular preload (pulmonary artery occlusion pressure, central venous pressure) and end-diastolic ventricular volumes/cardiac performance in healthy volunteers. DESIGN: Prospective, nonrandomized, nonblinded interventional study. SETTING: Cardiac catheterization and echocardiography laboratories. SUBJECTS: Normal healthy volunteers (n = 12 group 1, n = 32 group 2). INTERVENTIONS: Pulmonary catheterization and radionuclide cineangiography (group 1) and volumetric echocardiography (group 2) during 3 L of normal saline infusion over 3 hrs. MEASUREMENTS AND MAIN RESULTS: In group 1, the initial pulmonary artery occlusion pressure and central venous pressure did not correlate significantly with initial end-diastolic ventricular volume indexes or cardiac performance (cardiac index and stroke volume index). Changes in pulmonary artery occlusion pressure and central venous pressure following saline infusion also did not correlate with changes in end-diastolic ventricular volume indexes or cardiac performance. In contrast, initial end-diastolic ventricular volume indexes and changes in these ventricular volume indexes in response to 3 L of normal saline loading correlated well with initial stroke volume index and changes in stroke volume index, respectively. The relationship between left ventricular end-diastolic volume index and stroke volume index was confirmed in group 2 subjects using mathematically independent techniques to measure these variables. In addition, initial central venous pressure, right ventricular end-diastolic volume index, pulmonary artery occlusion pressure, and left ventricular end-diastolic volume index failed to correlate significantly with changes in cardiac performance in response to saline infusion in group 1 subjects. CONCLUSIONS: Normal healthy volunteers demonstrate a lack of correlation between initial central venous pressure/pulmonary artery occlusion pressure and both end-diastolic ventricular volume indexes and stroke volume index. Similar results are found with respect to changes in these variables following volume infusion. In contrast, initial end-diastolic ventricular volume indexes and changes in end-diastolic ventricular volume indexes in response to saline loading correlate strongly with initial and postsaline loading changes in cardiac performance as measured by stroke volume index. These data suggest that the lack of correlation of these variables in specific patient groups described in other studies represents a more universal phenomenon that includes normal subjects. Neither central venous pressure nor pulmonary artery occlusion pressure appears to be a useful predictor of ventricular preload with respect to optimizing cardiac performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Catheterization of the Heart in Man with Use of a Flow-Directed Balloon-Tipped Catheter
Swan, H. J. C., Ganz, W., Forrester, J., Marcus, H., Diamond, G., & Chonette, D. (1970) · New England Journal of Medicine · doi:10.1056/nejm197008272830902 · Cited by 2,137
Sandham, J. D., Hull, R. D., Brant, R. F., Knox, L., Pineo, G. F., Doig, C. J., Laporta, D. P., Viner, S., Passerini, L., Devitt, H., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021108 · Cited by 1,529
Lewis, J. F., Kuo, L. C., Nelson, J. G., Limacher, M. C., & Quinones, M. A. (1984) · Circulation · doi:10.1161/01.cir.70.3.425 · Cited by 733
Sarnoff (1954) · doi:10.1161/01.cir.9.5.706 · Cited by 602 · cited 1×
“Others have suggested that an intact pericardium may be important in maintenance of the “normal” relationship between end-diastolic pressures and volumes (12, 46, 47).”
BackgroundNoninvasive Doppler determination of cardiac output in man. Clinical validation.
Huntsman, L. L., Stewart, D. K., Barnes, S. R., Franklin, S. B., Colocousis, J. S., & Hessel, E. A. (1983) · Circulation · doi:10.1161/01.cir.67.3.593 · Cited by 595
Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
Sakka, S. G., Reinhart, K., & Meier-Hellmann, A. (1999) · Intensive Care Medicine · doi:10.1007/s001340050962 · Cited by 262
Calvin, J. E., Driedger, A. A., & Sibbald, W. J. (1981) · Critical Care Medicine · doi:10.1097/00003246-198106000-00001 · Cited by 223
Effect of angina on the left ventricular diastolic pressure-volume relationship.
Mann, T., Brodie, B. R., Grossman, W., & McLaurin, L. P. (1977) · Circulation · doi:10.1161/01.cir.55.5.761 · Cited by 171
Diebel, L. N., Wilson, R. F., Heins, J., Larky, H., Warsow, K. M., & Wilson, S. (1994) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199412000-00014 · Cited by 148
Cited by
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Management of severe perioperative bleeding: Guidelines from the European Society of Anaesthesiology
Kozek-Langenecker, S. A., Afshari, A., Albaladejo, P., Santullano, C. A. A., De Robertis, E., Filipescu, D. C., Fries, D., Görlinger, K., Haas, T., Imberger, G., et al. (2013) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32835f4d5b · Cited by 909
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
“Kumar et al (65) 2007 Healthy volunteer 12 Echocardiography N Various 3,000 Crystalloid 0.”
BackgroundInfluentialChanges in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
Osman, D., Ridel, C., Ray, P., Monnet, X., Anguel, N., Richard, C., & Teboul, J.-L. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000249851.94101.4f · Cited by 695
Venous Function and Central Venous Pressure: A Physiologic Story
Gelman, S., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181672607 · Cited by 575
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Antonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
Levitov, A., Frankel, H. L., Blaivas, M., Kirkpatrick, A. W., Su, E., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001847 · Cited by 440
Acute respiratory distress syndrome
Sweeney, R. M., & McAuley, D. F. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00578-x · Cited by 398
Transpulmonary thermodilution: advantages and limits
Monnet, X., & Teboul, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1739-5 · Cited by 285
Hofer, C. K., Müller, S. M., Furrer, L., Klaghofer, R., Genoni, M., & Zollinger, A. (2005) · Chest · doi:10.1378/chest.128.2.848 · Cited by 279
Intra-abdominal hypertension in the critically ill: it is time to pay attention
Malbrain, M. L. N. G., Deeren, D., & De Potter, T. J. R. (2005) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000155355.86241.1b · Cited by 261
Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions
De Backer, D., & Vincent, J.-L. (2018) · Critical Care · doi:10.1186/s13054-018-1959-3 · Cited by 255
Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients
Goepfert, M. S. G., Reuter, D. A., Akyol, D., Lamm, P., Kilger, E., & Goetz, A. E. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0404-2 · Cited by 254
Cecconi, M., Parsons, A. K., & Rhodes, A. (2011) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32834699cd · Cited by 244
Bedside Ultrasonography in the ICU
Beaulieu, Y., & Marik, P. E. (2005) · Chest · doi:10.1378/chest.128.2.881 · Cited by 233
Hofer, C. K., Senn, A., Weibel, L., & Zollinger, A. (2008) · Critical Care · doi:10.1186/cc6933 · Cited by 222
“CVP, the standard pressure preload variable, did not adequately reflect preload status [2,4] and is therefore unsuitable for predicting ventricular response to fluid loading.”
BackgroundHemodynamic Responses to Rapid Saline Loading: The Impact of Age, Sex, and Heart Failure
Fujimoto, N., Borlaug, B. A., Lewis, G. D., Hastings, J. L., Shafer, K. M., Bhella, P. S., Carrick-Ranson, G., & Levine, B. D. (2013) · Circulation · doi:10.1161/circulationaha.112.111302 · Cited by 209
“However, there are limited data on what represents a normal versus pathological response of PCWP to volume infusion.(4) Similarly, normative data on how pulmonary arterial pressures respond to increased blood flow and increased left-side filling pressures with saline infusion are lacking.”
Mebazaa, A., Pitsis, A. A., Rudiger, A., Toller, W., Longrois, D., Ricksten, S.-E., Bobek, I., De Hert, S., Wieselthaler, G., Schirmer, U., et al. (2010) · Critical Care · doi:10.1186/cc8153 · Cited by 208
“Pressure estimates, such as central venous pressure and pulmonary capillary wedge pressure (PCWP) - previously considered reliable measures of RV and LV preload - are generally insensitive indicators of volaemia; while low values may refl ect hypovolaemia, high values do not necessarily indicate volume overload [ 44-4…”
Bioinspired Gradient Conductivity and Stiffness for Ultrasensitive Electronic Skins
Lee, Y., Myoung, J., Cho, S., Park, J., Kim, J., Lee, H., Lee, Y., Lee, S., Baig, C., & Ko, H. (2021) · ACS Nano · doi:10.1021/acsnano.0c09581 · Cited by 205
Cardiac output monitoring: an integrative perspective
Alhashemi, J. A., Cecconi, M., & Hofer, C. K. (2011) · Critical Care · doi:10.1186/cc9996 · Cited by 202
“Although the majority of physicians use CVP in order to guide fluid therapy [34], several studies have shown lack of correlation between CVP and SV [35, 36].”
BackgroundHemodynamic Evaluation and Monitoring in the ICU
Pinsky, M. R. (2007) · Chest · doi:10.1378/chest.07-0073 · Cited by 202
Predictors of Acute Kidney Injury in Septic Shock Patients: An Observational Cohort Study
Plataki, M., Kashani, K., Cabello-Garza, J., Maldonado, F., Kashyap, R., Kor, D. J., Gajic, O., & Cartin-Ceba, R. (2011) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05480610 · Cited by 193
Bednarczyk, J. M., Fridfinnson, J. A., Kumar, A., Blanchard, L., Rabbani, R., Bell, D., Funk, D., Turgeon, A. F., Abou-Setta, A. M., & Zarychanski, R. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002554 · Cited by 192
“Static indices such as the central venous pressure (CVP) consistently fail to predict fluid responsiveness, calling to question their utility in goal-directed therapy algorithms (8, 9).”
BackgroundSelf-citationCerebral Salt Wasting: Pathophysiology, Diagnosis, and Treatment
Yee, A. H., Burns, J. D., & Wijdicks, E. F. M. (2010) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2009.10.011 · Cited by 183
Perioperative Management of Patients Undergoing Transsphenoidal Pituitary Surgery
Nemergut, E. C., Dumont, A. S., Barry, U. T., & Laws, E. R. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000166976.61650.ae · Cited by 181
“Problems using CVP and PAoP monitoring to predict LVEDV may extend to normal patients as well (82).”
Central venous pressure: A useful but not so simple measurement
Magder, S. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000227646.98423.98 · Cited by 174
Kuzkov, V. V., Kirov, M. Y., Sovershaev, M. A., Kuklin, V. N., Suborov, E. V., Waerhaug, K., & Bjertnaes, L. J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000218817.24208.2e · Cited by 171
“This finding is consistent with the results of other investigators (35, 42).”
ResultFunctional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
“Regrettably, neither CVP nor Ppao predict a patient’s response to fluid challenges [28-30].”
BackgroundMonitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
“…Geneva Medical School, 1211 Geneva 14, Switzerland 5 Centre de Recherche en Nutrition Humaine Auvergne, UMR 1019 Nutrition Humaine, INRA, Clermont Université, Service de Nutrition Clinique, CHU de Clermont-Ferrand, 63009 Clermont-Ferrand, France 6 Intensive Care Division, Geneva University…”
Singh, Y., Villaescusa, J. U., da Cruz, E. M., Tibby, S. M., Bottari, G., Saxena, R., Guillén, M., Herce, J. L., Di Nardo, M., Cecchetti, C., et al. (2020) · Critical Care · doi:10.1186/s13054-020-03326-2 · Cited by 86
Metadata
- Authors
- Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., & Parrillo, J. E.
- Venue
- Critical Care Medicine
- Published
- 2004-03
- Volume
- 32
- Issue
- 3
- Pages
- 691-699
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2146351148
- Cited by
- 800
- References
- 20
- FWCI
- 31.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.