The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population*
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The objective was to assess the risk of central venous catheter infection with respect to the site of insertion in an intensive care unit population. The subclavian, internal jugular, and femoral sites were studied. DESIGN: An epidemiologic, prospective, observational study. SETTING: The setting is a well-functioning intensive care unit under a unified critical care medicine division in a university teaching hospital. Critical care medicine attendings and fellows covered on site 17 and 24 hrs per day, respectively. PATIENTS: Patients were critically ill. All patients were triaged into the intensive care unit by on-site critical care medicine fellows. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: In an intensive care unit population, we prospectively studied the incidence of central venous catheter infection and colonization at the subclavian, internal jugular, and femoral sites. The optimal insertion site for each individual patient was selected by experienced intensive care physicians (critical care medicine attendings and fellows). All of the operators were proficient in inserting catheters at all three sites. Confounding factors were eliminated; there were a limited number of experienced operators inserting the catheters, a uniform protocol stressing strict sterile insertion was enforced, and standardized continuous catheter care was provided by dedicated intensive care nurses proficient in all aspects of central venous catheter care. Two groups of patients were analyzed. Group 1 was patients with one catheter at one site, and group 2 was patients with catheters at multiple sites. Group 1 was the primary analysis, whereas group 2 was supporting.A total of 831 central venous catheters and 4,735 catheter days in 657 patients were studied. The incidence of catheter infection (4.01/1,000 catheter days, 2.29% catheters) and colonization (5.07/1,000 catheter days, 2.89% catheters) was low overall. In group 1, the incidence of infection was subclavian: 0.881 infections/1,000 catheter days (0.45%), internal jugular: 0/1,000 (0%), and femoral: 2.98/1,000 (1.44%; p = .2635). The incidence of colonization was subclavian: 0.881 colonization/1,000 catheter days (0.45%), internal jugular: 2.00/1,000 (1.05%), and femoral: 5.96/1,000 (2.88%, p = .1338). There was no statistically significant difference in the incidence of infection and colonization or duration of catheters (p = .8907) among the insertion sites. In group 2, there was also no statistically significant difference in the incidence of infection and colonization among the three insertion sites. CONCLUSION: In an intensive care unit population, the incidence of central venous catheter infection and colonization is low overall and, clinically and statistically, is not different at all three sites when optimal insertion sites are selected, experienced operators insert the catheters, strict sterile technique is present, and trained intensive care unit nursing staff perform catheter care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743 · cited 1×
“Aside from the potential risks, each insertion site provides unique information for goal-directed therapy (14).”
BackgroundA Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027 · cited 1×
“(22) did not find contaminated catheters to cause deleterious infectious outcomes; rather than clouding the definition of infectious end points, we uniformly excluded these catheters.”
BackgroundMerrer, J. (2001) · JAMA · doi:10.1001/jama.286.6.700 · Cited by 1,187 · cited 7×
“Operators with different levels of expertise have confounded infection end points in many of the catheter infection studies thus far conducted (6).”
BackgroundResultInfluentialPrevention of Intravascular Catheter–Related Infections
Mermel, L. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-5-200003070-00009 · Cited by 919 · cited 2×
“Some estimate 500–4,000 deaths annually (3, 4) at a cost per infection of 3,124 Euros in Europe (5) and $3,700–$29,000 in the United States (3).”
BackgroundPrevention of Intravascular Catheter-Related Infections
(2021) · Indian Journal of Continuing Nursing Education · doi:10.4103/2230-7354.320831 · Cited by 855
A Comparison of Two Antimicrobial-Impregnated Central Venous Catheters
Darouiche, R. O., Raad, I. I., Heard, S. O., Thornby, J. I., Wenker, O. C., Gabrielli, A., Berg, J., Khardori, N., Hanna, H., Hachem, R., et al. (1999) · New England Journal of Medicine · doi:10.1056/nejm199901073400101 · Cited by 804
Raad, I. I., Hohn, D. C., Gilbreath, B. J., Suleiman, N., Hill, L. A., Bruso, P. A., Marts, K., Mansfield, P. F., & Bodey, G. P. (1994) · Infection Control & Hospital Epidemiology · doi:10.1086/646902 · Cited by 774
Maki, D. G., Stolz, S. M., Wheeler, S., & Mermel, L. A. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-4-199708150-00001 · Cited by 753
Comparison of different methods for measuring intra-abdominal pressure
Gudmundsson, F. F., Viste, A., Gislason, H., & Svanes, K. (2002) · Intensive Care Medicine · doi:10.1007/s00134-001-1187-0 · Cited by 685 · cited 1×
“For example, SC and IJ catheters provide central venous pressure monitoring for proper fluid management in septic shock, whereas FEM catheters provide intraabdominal pressure monitoring (15) for timely surgical decompression to prevent shock and multiple-organ failure in trauma situations.”
BackgroundEggimann, P., Harbarth, S., Constantin, M.-N., Touveneau, S., Chevrolet, J.-C., & Pittet, D. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02291-1 · Cited by 444 · cited 1×
“(24) showed a decrease in bloodstream infection from 22.”
BackgroundEvaluation of Outcome of Intravenous Catheter-related Infections in Critically Ill Patients
RELLO, J., OCHAGAVIA, A., SABANES, E., ROQUE, M., MARISCAL, D., REYNAGA, E., & VALLES, J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.3.9911093 · Cited by 354 · cited 1×
“Some estimate 500–4,000 deaths annually (3, 4) at a cost per infection of 3,124 Euros in Europe (5) and $3,700–$29,000 in the United States (3).”
BackgroundSubclavian Vein Catheterizations: A Prospective Study
BERNARD, R. W., & STAHL, W. M. (1971) · Annals of Surgery · doi:10.1097/00000658-197102000-00002 · Cited by 343 · cited 3×
“They found the incidence of mechanical (26) and infectious (27) complications to be much lower with experienced operators.”
BackgroundResultInfluentialRichet, H., Hubert, B., Nitemberg, G., Andremont, A., Buu-Hoi, A., Ourbak, P., Galicier, C., Veron, M., Boisivon, A., & Bouvier, A. M. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.11.2520-2525.1990 · Cited by 326
Coopersmith, C. M., Rebmann, T. L., Zack, J. E., Ward, M. R., Corcoran, R. M., Schallom, M. E., Sona, C. S., Buchman, T. G., Boyle, W. A., Polish, L. B., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200201000-00009 · Cited by 304 · cited 2×
“As discussed earlier (25), this is fact alone likely accounts for Merrer and colleagues’ (6) higher infection rate at the FEM site.”
BackgroundOliver, M. J., Callery, S. M., Thorpe, K. E., Schwab, S. J., & Churchill, D. N. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00439.x · Cited by 269
Risk of Infection Due to Central Venous Catheters: Effect of Site of Placement and Catheter Type
Goetz, A. M., Wagener, M. M., Miller, J. M., & Muder, R. R. (1998) · Infection Control & Hospital Epidemiology · doi:10.1086/647742 · Cited by 230
Consensus Statement on the Triage of Critically III Patients
Sprung, C. L. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510390070032 · Cited by 183
Guidelines on admission and discharge for adult intermediate care units
Nasraway, S. A., Cohen, I. L., Dennis, R. C., Howenstein, M. A., Nikas, D. K., Warren, J., & Wedel, S. K. (1998) · Critical Care Medicine · doi:10.1097/00003246-199803000-00039 · Cited by 171 · cited 2×
“Copyright © 2005 by the Society of Critical Care Medicine and Lippincott Williams & Wilkins DOI: 10.1097/01.”
MethodInfluentialClimo, M. W., Diekema, D. J., Warren, D. K., Herwaldt, L. A., Perl, T. M., Peterson, L. R., Plaskett, T., Price, C. S., Sepkowitz, K. A., Solomon, S., et al. (2003) · Infection Control and Hospital Epidemiology · doi:10.1086/502163 · Cited by 152 · cited 1×
“Comparing catheter infection rates among catheters in non-ICU areas with catheters in ICU areas adds a serious confounding factor in the study because the reported incidence of CVC infection is higher in non-ICU areas (16).”
BackgroundPittet, D. (1995) · Archives of Internal Medicine · doi:10.1001/archinte.155.11.1177 · Cited by 115 · cited 3×
“Pittet and Wenzel(1) reported that catheter infection carries an odds ratio for death as high as 20.45 (95% confidence interval, 18.9–22.1); others have reported similar findings (2).”
BackgroundInfluentialSubclavian Vein Catheterizations: A Prospective Study
Bernard, R. W., Stahl, W. M., & Chase, R. M. (1971) · Annals of Surgery · doi:10.1097/00000658-197102000-00003 · Cited by 112
Pawar, M., Mehta, Y. B., Kapoor, P., Sharma, J., Gupta, A., & Trehan, N. K. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.03.009 · Cited by 98 · cited 1×
“Catheter duration is a risk factor for infection (11, 12, 20, 21, 30).”
BackgroundHanna, H. A., RAAD, I. I., Hackett, B. C., Wallace, S. K., Price, K., Coyle, D. E., & Parmley, C. L. (2003) · CHEST Journal · doi:10.1378/chest.124.3.1030 · Cited by 87 · cited 1×
“Now that antimicrobial (21, 31) and antiseptic (32) impregnated catheters are shown to significantly decrease catheter infection and colonization, catheter duration can increase with further minimizing of the risk of infection.”
BackgroundRisk Factors and Clinical Impact of Central Line Infections in the Surgical Intensive Care Unit
Charalambous, C. P., Swoboda, S. M., Dick, J., Perl, T., & Lipsett, P. A. (1998) · Archives of Surgery · doi:10.1001/archsurg.133.11.1241 · Cited by 69 · cited 1×
“IJ catheters are reported to have high rates of bacterial contamination (11, 12, 13).”
BackgroundSaint, S. K., Savel, R. H., & Matthay, M. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2110035 · Cited by 68 · cited 1×
“Some estimate 500–4,000 deaths annually (3, 4) at a cost per infection of 3,124 Euros in Europe (5) and $3,700–$29,000 in the United States (3).”
BackgroundInfections Related to Central Venous Catheters
Corona, M. L., Peters, S. G., Narr, B. J., & Thompson, R. L. (1990) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65159-3 · Cited by 60 · cited 2×
“Fourteen days duration is an institutional policy to avoid catheter infection from excess catheter duration (11, 12, 20, 21); the duration is based on the incidence of CVC infection from the institution’s infection control program.”
BackgroundENDEMIC BACTEREMIA IN COLUMBIA, SOUTH CAROLINA
Bryan, C. S., Hornung, C. A., Reynolds, K. L., & BRENNER, E. R. (1986) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a114205 · Cited by 51 · cited 4×
“aureus (2) Candida albicans Enterococcus Staphylococcus coagulase negative S.”
BackgroundInfluentialHm, L., Creger, R. J., Bloom, A. D., & Shenk, R. (1990) · PubMed · Cited by 21
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Pittiruti, M., Hamilton, H., Biffi, R., MacFie, J., & Pertkiewicz, M. (2009) · Clinical Nutrition · doi:10.1016/j.clnu.2009.03.015 · Cited by 698
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
Metadata
- Authors
- Deshpande, K. S., Hatem, C., Ulrich, H. L., Currie, B. P., Aldrich, T. K., Bryan-Brown, C. W., & Kvetan, V.
- Venue
- Critical Care Medicine
- Published
- 2005-01
- Volume
- 33
- Issue
- 1
- Pages
- 13-20
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1995084155
- Cited by
- 211
- References
- 28
- FWCI
- 27.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.