Poor validity of residual volumes as a marker for risk of aspiration in critically ill patients*

McClave, Stephen A., Lukan, James K., Stefater, James A., Lowen, Cynthia C., Looney, Stephen W., Matheson, Paul J., Gleeson, Kevin, Spain, David A.·2005·Critical Care Medicine

Abstract

BACKGROUND AND AIMS: Elevated residual volumes (RV), considered a marker for the risk of aspiration, are used to regulate the delivery of enteral tube feeding. We designed this prospective study to validate such use. METHODS: Critically ill patients undergoing mechanical ventilation in the medical, coronary, or surgical intensive care units in a university-based tertiary care hospital, placed on intragastric enteral tube feeding through nasogastric or percutaneous endoscopic gastrostomy tubes, were included in this study. Patients were fed Probalance (Nestle USA) to provide 25 kcal/kg per day (to which 10 yellow microscopic beads and 4.5 mL of blue food coloring per 1,500 mL was added). Patients were randomized to one of two groups based on management of RV: cessation of enteral tube feeding for RV >400 mL in study patients or for RV >200 mL in controls. Acute Physiology and Chronic Health Evaluation (APACHE) III, bowel function score, and aspiration risk score were determined. Bedside evaluations were done every 4 hrs for 3 days to measure RV, to detect blue food coloring, to check patient position, and to collect secretions from the trachea and oropharynx. Aspiration/regurgitation events were defined by the detection of yellow color in tracheal/oropharyngeal samples by fluorometry. Analysis was done by analysis of variance, Spearman's correlation, Student's t-test, Tukey's method, and Cochran-Armitage test. RESULTS: Forty patients (mean age, 44.6 yrs; range, 18-88 yrs; 70% male; mean APACHE III score, 40.9 [range, 12-85]) were evaluated (21 on nasogastric, 19 on percutaneous endoscopic gastrostomy feeds) and entered into the study. Based on 1,118 samples (531 oral, 587 tracheal), the mean frequency of regurgitation per patient was 31.3% (range, 0% to 94%), with a mean RV for all regurgitation events of 35.1 mL (range, 0-700 mL). The mean frequency of aspiration per patient was 22.1% (range, 0% to 94%), with a mean RV for all aspiration events of 30.6 mL (range, 0-700 mL). The median RV for both regurgitation and aspiration events was 5 mL. Over a wide range of RV, increasing from 0 mL to >400 mL, the frequency of regurgitation and aspiration did not change appreciably. Aspiration risk and bowel function scores did not correlate with the incidence of aspiration or regurgitation. Blue food coloring was detected on only three of the 1,118 (0.27%) samples. RV was < or =50 mL on 84.1% and >400 mL on 1.4% of bedside evaluations. Sensitivities for detecting aspiration per designated RV were as follows: 400 mL = 1.5%; 300 mL = 2.3%; 200 mL = 3.0%; and 150 mL = 4.5%. Low RV did not assure the absence of events, because the frequency of aspiration was 23.0% when RV was <150 mL. Raising the designated RV for cessation of enteral tube feeding from 200 mL to 400 mL did not increase the risk, because the frequency of aspiration was no different between controls (21.6%) and study patients (22.6%). The frequency of regurgitation was significantly less for patients with percutaneous endoscopic gastrostomy tubes compared with those with nasogastric tubes (20.3% vs. 40.7%, respectively; p = .046). There was no correlation between the incidence of pneumonia and the frequency of regurgitation or aspiration. CONCLUSIONS: Blue food coloring should not be used as a clinical monitor. Converting nasogastric tubes to percutaneous endoscopic gastrostomy tubes may be a successful strategy to reduce the risk of aspiration. No appropriate designated RV level to identify aspiration could be derived as a result of poor sensitivity over a wide range of RV. Study results do not support the conventional use of RV as a marker for the risk of aspiration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.ccm.0000153413.46627.3a

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 368

Metadata

Authors
McClave, S. A., Lukan, J. K., Stefater, J. A., Lowen, C. C., Looney, S. W., Matheson, P. J., Gleeson, K., & Spain, D. A.
Venue
Critical Care Medicine
Published
2005-02
Volume
33
Issue
2
Pages
324-330
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2088081911
Cited by
368
References
26
FWCI
16.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Poor validity of residual volumes as a marker for risk of aspiration in critically ill patients*. https://app.cochat.ai/papers/10.1097/01.ccm.0000153413.46627.3a
The paper
McClave, S. A., Lukan, J. K., Stefater, J. A., Lowen, C. C., Looney, S. W., Matheson, P. J., Gleeson, K., & Spain, D. A. (2005). Poor validity of residual volumes as a marker for risk of aspiration in critically ill patients*. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000153413.46627.3a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.