A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration*
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Leakage of fluid from the subglottic space to the lungs occurs along the longitudinal folds within the wall of an inflated high-volume, low-pressure (HVLP) cuff. The low-volume, low-pressure (LVLP) cuff does not have these folds yet allows for convenient and reliable control of tracheal wall pressure. Pulmonary aspiration during anesthesia has been linked with postoperative pneumonia and during critical illness causes ventilator-associated pneumonia. DESIGN: Prospective, blinded, randomized controlled trial; prospective observational study; and benchtop models. SETTING: Department of Anaesthesia and Critical Care, Queen Elizabeth Hospital. PATIENTS: Anesthetized patients (n=38) and critically ill patients with either an LVLP or HVLP cuffed tracheostomy tube following swallow assessments (n=67). INTERVENTIONS: The LVLP cuff was compared with HVLP cuffs for leakage of dye placed in the subglottic space to the tracheobronchial tree in a rigid tracheal model and a benchtop pig trachea model (before and after a standardized cuff movement). MEASUREMENTS AND MAIN RESULTS: In the rigid tracheal model, the incidence of leakage was 0% in the LVLP group and 100% in the HVLP group (p<.01). Dye leakage in the pig tracheal model with HVLP cuffs was 44% before tube movement, increasing to 79% afterward. The LVLP cuff did not leak in the pig tracheal model. Dye leakage in anesthetized patients was 0% before movement and 5% after in the LVLP group and in the HVLP group 22% increasing to 67% after movement (p<.001). Forty-nine percent of swallow assessments were scored as failed in the critical care patients with HVLP tracheostomy tube cuffs, and there were no episodes of aspiration following swallow assessment in the LVLP group (p<.05). CONCLUSIONS: The LVLP cuffed tracheal and tracheostomy tubes reduced pulmonary aspiration in the benchtop models and in anesthetized and critically ill patients. The single failure of the LVLP cuff in the anesthesia group was probably associated with accidental endobronchial intubation following tube movement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pneumonia in intubated patients: role of respiratory airway care.
Rello, J., Soñora, R., Jubert, P., Artigas, A., Rué, M., & Vallés, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.1.8680665 · Cited by 703
Leakage of fluid past the tracheal tube cuff in a benchtop model
Young, P., Rollinson, M., Downward, G., & Henderson, S. J. (1997) · British Journal of Anaesthesia · doi:10.1093/bja/78.5.557 · Cited by 629
Self-citationContinuous Aspiration of Subglottic Secretions in Preventing Ventilator-Associated Pneumonia
Valles, J., Artigas, A., Rello, J., Bonsoms, N., Fontanals, D., Blanch, L., Fernandez, R., Baigorri, F., & Mestre, J. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-3-199502010-00004 · Cited by 549
Aspiration during anaesthesia: a computer‐aided study of 185 358 anaesthetics
OLSSON, G. L., HALLEN, B., & HAMBRAEUS‐JONZON, K. (1986) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1986.tb02373.x · Cited by 523
Implications of endotracheal tube biofilm for ventilator-associated pneumonia
Adair, C. G., Gorman, S. P., Feron, B. M., Byers, L. M., Jones, D. S., Goldsmith, C. E., Moore, J. E., Kerr, J. R., Curran, M. D., Hogg, G., et al. (1999) · Intensive Care Medicine · doi:10.1007/s001340051014 · Cited by 403
Aspiration beyond endotracheal cuffs
Seegobin, R. D., & Hasselt, G. L. (1986) · Canadian Anaesthetists’ Society Journal · doi:10.1007/bf03010737 · Cited by 367
Prevention of hospital-associated pneumonia and ventilator-associated pneumonia
Kollef, M. H. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000128569.09113.fb · Cited by 366
Mahul, P., Auboyer, C., Jospe, R., Ros, A., Guerin, C., El Khouri, Z., Galliez, M., Dumont, A., & Gaudin, O. (1992) · Intensive Care Medicine · doi:10.1007/bf01706421 · Cited by 350
Kollef, M. H., Skubas, N. J., & Sundt, T. M. (1999) · Chest · doi:10.1378/chest.116.5.1339 · Cited by 308
Prevention of Ventilator-Associated Pneumonia: An Evidence-Based Systematic Review
Collard, H. R., Saint, S., & Matthay, M. A. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-6-200303180-00015 · Cited by 304
Estes, R. J., & Meduri, G. U. (1995) · Intensive Care Medicine · doi:10.1007/bf01705418 · Cited by 284
Smulders, K., van der Hoeven, H., Weers-Pothoff, I., & Vandenbroucke-Grauls, C. (2002) · Chest · doi:10.1378/chest.121.3.858 · Cited by 247
Risk Factors for Ventilator‐Associated Pneumonia: From Epidemiology to Patient Management
Bonten, M. J. M., Kollef, M. H., & Hall, J. B. (2004) · Clinical Infectious Diseases · doi:10.1086/383039 · Cited by 238
de Lassence, A., Alberti, C., Azoulay, É., Le Miere, E., Cheval, C., Vincent, F., Cohen, Y., Garrouste-Orgeas, M., Adrie, C., Troche, G., et al. (2002) · Anesthesiology · doi:10.1097/00000542-200207000-00021 · Cited by 173
Inflation of a pressure-limited cuff inside a model trachea
Young, P. J., & Young, W. H. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00252-7 · Cited by 168
Self-citationEvaluation of continuous aspiration of subglottic secretion in an in vivo study*
Berra, L. M., Marchi, L. D., Panigada, M., Yu, Z., Baccarelli, A., & Kolobow, T. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000142575.86468.9b · Cited by 136
Berra, L. M., Marchi, L. D., Yu, Z., Laquerrière, P., Baccarelli, A., & Kolobow, T. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00017 · Cited by 133
Postoperative pneumonia: a prospective study of risk factors and morbidity.
Ephgrave, K. S., Kleiman‐Wexler, R. L., Pfaller, M. A., Booth, B. M., Werkmeister, L., & Young, S. (1993) · PubMed · Cited by 120
van Nieuwenhoven, C. A., Buskens, E., Bergmans, D. C. J. J., van Tiel, F. H., Ramsay, G., & Bonten, M. J. M. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000104111.61317.4b · Cited by 86
Prevention of tracheal aspiration using the pressure‐limited tracheal tube cuff
Young, P., Basson, C., Hamilton, D., & Ridley, S. (1999) · Anaesthesia · doi:10.1046/j.1365-2044.1999.00850.x · Cited by 49
Self-citationBo, H., He, L., & Qu, J. (2000) · PubMed · Cited by 47
New insights into the pathogenesis of ventilator-associated pneumonia
Inglis, T. J. J. (1995) · Journal of Hospital Infection · doi:10.1016/0195-6701(95)90045-4 · Cited by 25
Dollars and sense in the intensive care unit: The costs of ventilator-associated pneumonia *
Shorr, A. F., & Wunderink, R. G. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000063086.33840.54 · Cited by 22
Berra, L. M., Panigada, M., Marchi, L. D., Greco, G., -Xi, Y. Z., Baccarelli, A., Pohlmann, J. R., Costello, K., Appleton, J., Mahar, R. K., et al. (2003) · PubMed · Cited by 20
Young, P., & Blunt, M. C. (1999) · Critical Care · doi:10.1186/cc357 · Cited by 9
Self-citation
Cited by
Shander, A., Fleisher, L. A., Barie, P. S., Bigatello, L. M., Sladen, R. N., & Watson, C. B. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31821f0522 · Cited by 272
Ventilator-associated pneumonia: pathobiological heterogeneity and diagnostic challenges
Howroyd, F., Chacko, C., MacDuff, A., Gautam, N., Pouchet, B., Tunnicliffe, B., Weblin, J., Gao-Smith, F., Ahmed, Z., Duggal, N. A., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-50805-z · Cited by 162
Li Bassi, G., Zanella, A., Cressoni, M., Stylianou, M., & Kolobow, T. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0000299741.32078.e9 · Cited by 119
Ventilator-associated pneumonia: the central role of transcolonization.
Soussan, R., Schimpf, C., Pilmis, B., Degroote, T., Tran, M., Bruel, C., & Philippart, F. (2019) · Journal of Critical Care · doi:10.1016/j.jcrc.2018.12.005 · Cited by 46
“Other clinical parameters, such as deglutition may play a similar role in the lack of impermeability [65].”
Background
Metadata
- Authors
- Young, P. J., Pakeerathan, S., Blunt, M. C., & Subramanya, S.
- Venue
- Critical Care Medicine
- Published
- 2006-03
- Volume
- 34
- Issue
- 3
- Pages
- 632-639
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1970170506
- Cited by
- 296
- References
- 25
- FWCI
- 74.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.