Blood pressure variability: its measurement and significance in hypertension
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The occurrence of blood pressure fluctuations over time has been documented since the 18th century, but the clinical importance of this phenomenon is only now being recognized. The introduction of ambulatory blood pressure monitoring in the late 1960s represented a major step forward in the study of blood pressure behaviour and helped to characterize the relationship between blood pressure variability and cardiovascular disease. In hypertension, blood pressure variability increases with increasing blood pressure and correlates closely with target-organ damage, independently of absolute blood pressure values. This has important consequences for treatment, which in the past has focused on reducing mean blood pressure values as the main goal. Experimental evidence suggests that drugs capable of buffering or reducing blood pressure variability may confer additional benefits on target-organ protection. Effective target-organ protection could best be afforded by antihypertensive agents that provide efficient 24-h blood pressure control and also stabilize blood pressure variability. Mathematical indices, such as the trough:peak ratio and the smoothness index, provide useful measures of the homogeneity of the antihypertensive effect over 24 h; optimum control is provided by drugs with a trough:peak ratio close to 1 and a smoothness index > 1, as is observed with long-acting drugs such as telmisartan or amlodipine. Recently, a direct relationship was demonstrated between homogeneous blood pressure control and treatment-induced regression of left ventricular hypertrophy, emphasizing the importance of smooth 24-h blood pressure control. In conclusion, the goals of antihypertensive treatment should consider the reduction of both 24-h mean blood pressure and its variability. Long-lasting drugs or drug combinations are preferable to ensure a homogeneous and smooth 24-h blood pressure profile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circadian Variation in the Frequency of Onset of Acute Myocardial Infarction
Muller, J. E., Stone, P. H., Turi, Z. G., Rutherford, J. D., Czeisler, C. A., Parker, C., Poole, W. K., Passamani, E., Roberts, R., Robertson, T., et al. (1985) · New England Journal of Medicine · doi:10.1056/nejm198511213132103 · Cited by 1,884
Kario, K., Pickering, T. G., Umeda, Y., Hoshide, S., Hoshide, Y., Morinari, M., Murata, M., Kuroda, T., Schwartz, J. E., & Shimada, K. (2003) · Circulation · doi:10.1161/01.cir.0000056521.67546.aa · Cited by 1,250
Parati, G., Pomidossi, G., Albini, F., Malaspina, D., & Mancia, G. (1987) · Journal of Hypertension · doi:10.1097/00004872-198702000-00013 · Cited by 952
Self-citationPrognostic value of 24-hour blood pressure variability
Frattola, A., Parati, G., Cuspidi, C., Albini, F., & Mancia, G. (1993) · Journal of Hypertension · doi:10.1097/00004872-199310000-00019 · Cited by 659
Self-citationWillich, S. N., Levy, D., Rocco, M. B., Tofler, G. H., Stone, P. H., & Muller, J. E. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)91027-7 · Cited by 653
Circadian Rhythms of Epinephrine and Norepinephrine in Man*
LINSELL, C. R., LIGHTMAN, S. L., MULLEN, P. E., BROWN, M. J., & CAUSON, R. C. (1985) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-60-6-1210 · Cited by 399
Mancia, G., Parati, G., Hennig, M., Flatau, B., Omboni, S., Glavina, F., Costa, B., Scherz, R., Bond, G., & Zanchetti, A. (2001) · Journal of Hypertension · doi:10.1097/00004872-200111000-00008 · Cited by 291
Self-citationContinuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.
di Rienzo, M., Grassi, G., Pedotti, A., & Mancia, G. (1983) · Hypertension · doi:10.1161/01.hyp.5.2.264 · Cited by 239
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Self-citationTatasciore, A., Renda, G., Zimarino, M., Soccio, M., Bilo, G., Parati, G., Schillaci, G., & De Caterina, R. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.090084 · Cited by 292
Self-citationSpectral Analysis of Heart Rate Variability: Time Window Matters
Li, K., Rüdiger, H., & Ziemssen, T. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00545 · Cited by 215
“Heart rate, blood pressure, and HRV parameters keep fluctuating constantly, both in the resting state and under various internal and external stimulations (9, 45, 46).”
BackgroundPowering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Kario, K., Shin, J., Chen, C., Buranakitjaroen, P., Chia, Y., Divinagracia, R., Nailes, J., Hoshide, S., Siddique, S., Sison, J., et al. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13652 · Cited by 164
Metadata
- Authors
- Parati, G.
- Venue
- Journal of Hypertension
- Published
- 2005-04
- Volume
- 23
- Issue
- Suppl 1
- Pages
- S19-S25
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2056622322
- Cited by
- 154
- References
- 8
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood pressure variability: its measurement and significance in hypertension. https://app.cochat.ai/papers/10.1097/01.hjh.0000165624.79933.d3
- The paper
- Parati, G. (2005). Blood pressure variability: its measurement and significance in hypertension. Journal of Hypertension. https://doi.org/10.1097/01.hjh.0000165624.79933.d3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.