Primary-care physicians' views about the use of home/self blood pressure monitoring: nationwide survey in Hungary
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To obtain unbiased views of primary-care physicians about home blood pressure monitoring (HBPM). METHODS: A mail survey was conducted in a random sample (n = 700) of all Hungarian primary-care physicians (n = 5112). Items in the questionnaire related to the extent and indications for use of HBPM, to the significance attributed to its results, to the methods of its use, and to concerns physicians had with HBPM. RESULTS: Of the 700 questionnaires, 405 (58%) could be analysed. HBPM was popular among the respondents: 60% of them had more then 50 patients on HBPM, 90% of them were recommending its use either 'often' or 'almost all the time', and 75% of them considered the results of HBPM of either 'considerable' or of 'extreme importance'. The most frequent indications for use were white-coat hypertension (97%), assessing 24-h drug effects (87%), improving compliance (82%), suspicion of hypotension (63%), and resistant hypertension (61%). Physicians actively recommended devices with an upper-arm cuff (83%), equipped with a built in memory (63%). Most respondents (67%) had someone in their offices to teach the patient the correct measurement technique. Surprisingly, 65% of the physicians only reviewed the data to obtain a 'general picture' and did not analyse the data. Most of the respondents (78%) encouraged their patients to call their offices, and 90% of them did receive a call. Main concerns with HBPM were the use of non-validated devices (75%), and patient preoccupation with blood pressure (55%). Areas for suggested improvements were the need for patient training facilities (48%), established measurement protocols (44%) and better methods of displaying readings (30%). CONCLUSIONS: We found an unexpected popularity in the use of HBPM among primary-care physicians. In order to fully exploit the benefits of HBPM, the concerns raised (validated devices, patient preoccupation) and areas to be improved upon (patient training, better methods of displaying results) will have to be addressed by researchers, societies and the industry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Ohkubo, T., Asayama, K., Kikuya, M., Metoki, H., Hoshi, H., Hashimoto, J., Totsune, K., Satoh, H., & Imai, Y. (2004) · Journal of Hypertension · doi:10.1097/00004872-200406000-00009 · Cited by 287
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189010 · Cited by 668
Role of Ambulatory and Home Blood Pressure Monitoring in Clinical Practice: A Narrative Review
Shimbo, D., Abdalla, M., Falzon, L., Townsend, R. R., & Muntner, P. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1270 · Cited by 190
“Physicians are concerned about the use of non-validated HBPM devices, lack of knowledge of where to purchase validated devices, lack of established measurement protocols, and the patient’s preoccupation with his or her own blood pressure, which may lead to anxiety (74-78).”
Logan, A. G., Dunai, A., McIsaac, W. J., Irvine, M. J., & Tisler, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f2fdd4 · Cited by 106
Self-citation
Metadata
- Authors
- Tislér, A., Dunai, A., Keszei, A., Fekete, B., Othmane, T. E. H., Torzsa, P., & Logan, A. G.
- Venue
- Journal of Hypertension
- Published
- 2006-09
- Volume
- 24
- Issue
- 9
- Pages
- 1729-1735
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2084991427
- Cited by
- 38
- References
- 4
- FWCI
- 2.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Primary-care physicians' views about the use of home/self blood pressure monitoring: nationwide survey in Hungary. https://app.cochat.ai/papers/10.1097/01.hjh.0000242396.15097.f3
- The paper
- Tislér, A., Dunai, A., Keszei, A., Fekete, B., Othmane, T. E. H., Torzsa, P., & Logan, A. G. (2006). Primary-care physicians' views about the use of home/self blood pressure monitoring: nationwide survey in Hungary. Journal of Hypertension. https://doi.org/10.1097/01.hjh.0000242396.15097.f3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.