MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTS
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Medical radiation exposure of the U.S. population has not been systematically evaluated for almost 25 y. In 1982, the per capita dose was estimated to be 0.54 mSv and the collective dose 124,000 person-Sv. The preliminary estimates of the NCRP Scientific Committee 6-2 medical subgroup are that, in 2006, the per capita dose from medical exposure (not including dental or radiotherapy) had increased almost 600% to about 3.0 mSv and the collective dose had increased over 700% to about 900,000 person-Sv. The largest contributions and increases have come primarily from CT scanning and nuclear medicine. The 62 million CT procedures accounted for 15% of the total number procedures (excluding dental) and over half of the collective dose. Nuclear medicine accounted for about 4% of all procedures but 26% of the total collective dose. Medical radiation exposure is now approximately equal to natural background radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sources and effects of ionizing radiation
(2018) · United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Reports · doi:10.18356/f48d655d-en · Cited by 3,985
Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2
(2006) · National Academies Press eBooks · doi:10.17226/11340 · Cited by 904
Patient exposure in medical X-ray imaging in Europe
Regulla, D. F., & Eder, H. (2005) · Radiation Protection Dosimetry · doi:10.1093/rpd/nch538 · Cited by 131
Shannoun, F., Zeeb, H., Back, C., & Blettner, M. (2006) · Health Physics · doi:10.1097/01.hp.0000205237.00357.58 · Cited by 25
Cited by
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures
Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Chen, J., Ting, H. H., Shah, N. D., Nasir, K., Einstein, A. J., & Nallamothu, B. K. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901249 · Cited by 1,338
Sodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990
Enewold, L., Zhu, K., Ron, E., Marrogi, A. J., Stojadinovic, A., Peoples, G. E., & Devesa, S. S. (2009) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-08-0960 · Cited by 809
Silva, A. C., Lawder, H. J., Hara, A., Kujak, J., & Pavlicek, W. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.2953 · Cited by 560
Gerber, T. C., Carr, J. J., Arai, A. E., Dixon, R. L., Ferrari, V. A., Gomes, A. S., Heller, G. V., McCollough, C. H., McNitt-Gray, M. F., Mettler, F. A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191650 · Cited by 487
Self-citationMarin, D., Nelson, R. C., Schindera, S. T., Richard, S., Youngblood, R. S., Yoshizumi, T. T., & Samei, E. (2010) · Radiology · doi:10.1148/radiol.09090094 · Cited by 484
Self-citationLeuraud, K., Richardson, D. B., Cardis, E., Daniels, R. D., Gillies, M., O'Hagan, J. A., Hamra, G. B., Haylock, R., Laurier, D., Moissonnier, M., et al. (2015) · The Lancet Haematology · doi:10.1016/s2352-3026(15)00094-0 · Cited by 442
A Systematic Review of Solid-Pseudopapillary Neoplasms: Are These Rare Lesions?
Law, J. K., Ahmed, A., Singh, V. K., Akshintala, V. S., Olson, M. T., Raman, S. P., Ali, S. Z., Fishman, E. K., Kamel, I., Canto, M. I., et al. (2014) · Pancreas · doi:10.1097/mpa.0000000000000061 · Cited by 380
Computed tomography and patient risk: Facts, perceptions and uncertainties
Power, S. P., Moloney, F., Twomey, M., James, K., O’Connor, O. J., & Maher, M. M. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i12.902 · Cited by 335
Papa, L., Lewis, L. M., Falk, J. L., Zhang, Z., Silvestri, S., Giordano, P., Brophy, G. M., Demery, J. A., Dixit, N. K., Ferguson, I., et al. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.08.021 · Cited by 332
Di Martino, M., Marin, D., Guerrisi, A., Baski, M., Galati, F., Rossi, M., Brozzetti, S., Masciangelo, R., Passariello, R., & Catalano, C. (2010) · Radiology · doi:10.1148/radiol.10091334 · Cited by 259
Exposing the Thyroid to Radiation: A Review of Its Current Extent, Risks, and Implications
Sinnott, B., Ron, E., & Schneider, A. B. (2010) · Endocrine Reviews · doi:10.1210/er.2010-0003 · Cited by 246
“In 2006 in the United States, 67 million CTs were performed, including 4–7 million on children (14, 29).”
BackgroundInfluentialPapa, L., Lewis, L. M., Silvestri, S., Falk, J. L., Giordano, P., Brophy, G. M., Demery, J. A., Liu, M. C., Mo, J., Akinyi, L., et al. (2012) · Journal of Trauma and Acute Care Surgery · doi:10.1097/ta.0b013e3182491e3d · Cited by 242
“GCS score 9–12 10 (10) 5 (19) 3 (6) 2 (11) 0 (0) 0 (0)”
Journy, N., Rehel, J.-L., Ducou Le Pointe, H., Lee, C., Brisse, H., Chateil, J.-F., Caer-Lorho, S., Laurier, D., & Bernier, M.-O. (2015) · British Journal of Cancer · doi:10.1038/bjc.2014.526 · Cited by 202
“…widespread use has raised concerns about potential risks of subsequent cancer, for CT leads to effective doses 5–20 times higher than conventional radiology (Shrimpton et al, 1991; Mettler et al, 2008)—corresponding to organ doses of some units to tens of milligrays (mGy) from each scan.”
BackgroundHistorical Review of Occupational Exposures and Cancer Risks in Medical Radiation Workers
Linet, M. S., Kim, K. P., Miller, D. L., Kleinerman, R. A., Simon, S. L., & de Gonzalez, A. B. (2010) · Radiation Research · doi:10.1667/rr2014.1 · Cited by 190
Performance of Ultrasound in the Diagnosis of Appendicitis in Children in a Multicenter Cohort
Mittal, M. K., Dayan, P. S., Macias, C. G., Bachur, R. G., Bennett, J., Dudley, N. C., Bajaj, L., Sinclair, K., Stevenson, M. D., Kharbanda, A. B., et al. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12161 · Cited by 175
Varghese, B., Kandanga, I., Puthussery, P., Vijayan, D., Babu, S. P. H., Aneesh, M. K., Noufal, M., Binu, E. V., Babu, A. C., James, S. M., et al. (2018) · Indian Journal of Radiology and Imaging · doi:10.4103/ijri.ijri_394_17 · Cited by 12
Metadata
- Authors
- Mettler, F. A., Thomadsen, B. R., Bhargavan, M., Gilley, D. B., Gray, J. E., Lipoti, J. A., McCrohan, J., Yoshizumi, T. T., & Mahesh, M.
- Venue
- Health Physics
- Published
- 2008-11
- Volume
- 95
- Issue
- 5
- Pages
- 502-507
- ISSN
- 0017-9078 (ISSN-L)
- OpenAlex
- W1994545291
- Cited by
- 507
- References
- 5
- FWCI
- 34.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.