Testing a Prosthetic Haptic Feedback Simulator With an Interactive Force Matching Task
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In Brief Prosthetic technology is a prime candidate for the integration of sensory feedback. Functional user testing of various haptic feedback modes is a necessary step to encourage commercial adoption. A haptic feedback simulator, using both a visual and vibrotactile representation of force, is coupled with an interactive force-matching task. This task provides an objective means to assess control of grasp force at three different target force levels. Results from eight subjects using a myoelectric prosthetic device show that visual feedback of force improved user performance at all force levels by reducing average force-matching error by 65%. Vibrotactile feedback led to improved performance in an experienced subgroup of subjects, showing 25% error reduction at the medium target force level. Furthermore, multiple practice sessions with the simulator are shown to reduce error rates. These findings suggest that prosthesis users may be able to improve their control of grasping force with a haptic feedback system. A haptic feedback simulator, such as the platform described here, will allow prosthesis users to practice with and customize the feedback to improve functionality and comfort. Prosthetic technology is a prime candidate for the integration of sensory feedback. Functional user testing of various haptic feedback modes is a necessary step to encourage commercial adoption. A haptic feedback simulator, using both a visual and vibrotactile representation of force, is coupled with an interactive forcematching task. These findings suggest that prosthesis users may be able to improve their control of grasping force with a haptic feedback system. A haptic feedback simulator, such as the platform described here, will allow prosthesis users to practice with and customize the feedback to improve functionality and comfort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 2×
“It is well understood how a haptic feedback channel can allow users to sense force without visual attention.(6,13,19) However, it is less clear whether the addition of a surrogate force feedback system to a myoelectric prosthesis would lead to functional improvements in control of grasp force.”
BackgroundPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“Other studies have also demonstrated that the use of vibrotactile feedback results in an improvement in grasping objects [89]–[91].”
BackgroundClemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“…(Asano et al., 2015), the sensation through stretching of the skin (Wheeler et al., 2010; Motamedi et al., 2017), the improvement in grasping force (Chatterjee et al., 2008; Cipriani et al., 2008, 2014; Saunders and Vijayakumar, 2011; Montagnani et al., 2015; Witteveen et al., 2015), the evoked…”
Gonzalez, J., Soma, H., Sekine, M., & Yu, W. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-33 · Cited by 87
Metadata
- Authors
- Chatterjee, A., Chaubey, P., Martin, J., & Thakor, N.
- Venue
- JPO Journal of Prosthetics and Orthotics
- Published
- 2008-04
- Volume
- 20
- Issue
- 2
- Pages
- 27-34
- ISSN
- 1040-8800 (ISSN-L)
- OpenAlex
- W2026212075
- Cited by
- 111
- References
- 3
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Testing a Prosthetic Haptic Feedback Simulator With an Interactive Force Matching Task. https://app.cochat.ai/papers/10.1097/01.jpo.0000311041.61628.be
- The paper
- Chatterjee, A., Chaubey, P., Martin, J., & Thakor, N. (2008). Testing a Prosthetic Haptic Feedback Simulator With an Interactive Force Matching Task. JPO Journal of Prosthetics and Orthotics. https://doi.org/10.1097/01.jpo.0000311041.61628.be
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.