CoChat

Home blood pressure self-monitoring: diagnostic performance in white-coat hypertension

Bayó, Joan, Cos, Francesc Xavier, Roca, Carme, Dalfó, Antoni, Martín-Baranera, Maria Montserrat, Albert, Botey · 2006 · Blood Pressure Monitoring
Cited by 40

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine the diagnostic performance of home blood pressure self-monitoring in white-coat hypertension using a 3-day reading program. MATERIAL AND METHODS: One hundred and ninety nontreated patients recently diagnosed with mild-moderate hypertension, selected consecutively at four primary healthcare centers in the city of Barcelona, were included. Each patient underwent morning and night home blood pressure self-monitoring with readings in triplicate for three consecutive days, followed by 24-h ambulatory blood pressure monitoring. The normality cut-off point value for home blood pressure self-monitoring and daytime ambulatory blood pressure monitoring was 135/85 mmHg. RESULTS: Sixty-three patients were diagnosed with white-coat hypertension with home blood pressure self-monitoring (34.8%; 95% confidence interval: 27.9-42.2) and 74 with ambulatory blood pressure monitoring (41.6%; 95% confidence interval: 33.7-48.4). No statistically significant differences were observed between home blood pressure self-monitoring values and those of diurnal ambulatory blood pressure monitoring [137.4 (14.3)/82.1 (8.3) mmHg vs. 134.8 (11.3)/81.3 (9.5) mmHg]. Home blood pressure self-monitoring diagnostic performance parameters were sensitivity 50.0% (95% confidence interval: 38.3-61.7), specificity 75.7% (95% confidence interval: 66.3-83.2), positive and negative predictive values 58.7% (95% confidence interval: 45.6-70.8) and 68.6% (95% confidence interval: 59.4-76.7), respectively, and positive and negative probability coefficients 2.05 and 0.66, respectively. Analysis of different normality cut-off points using a receiver operating characteristic curve failed to produce significant improvement in the diagnostic performance of home blood pressure self-monitoring. CONCLUSIONS: The diagnostic accuracy of a 3-day home blood pressure self-monitoring reading program in white-coat hypertension was poor. Ambulatory blood pressure monitoring continues to be the test of choice for this indication.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.mbp.0000200479.19046.94

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 40

Metadata

Authors
Bayó, J., Cos, F. X., Roca, C., Dalfó, A., Martín-Baranera, M. M., & Albert, B.
Venue
Blood Pressure Monitoring
Published
2006-04
Volume
11
Issue
2
Pages
47-52
ISSN
1359-5237 (ISSN-L)
OpenAlex
W1992029375
Cited by
40
References
2
FWCI
2.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home blood pressure self-monitoring: diagnostic performance in white-coat hypertension. https://app.cochat.ai/papers/10.1097/01.mbp.0000200479.19046.94
The paper
Bayó, J., Cos, F. X., Roca, C., Dalfó, A., Martín-Baranera, M. M., & Albert, B. (2006). Home blood pressure self-monitoring: diagnostic performance in white-coat hypertension. Blood Pressure Monitoring. https://doi.org/10.1097/01.mbp.0000200479.19046.94

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.