CoChat

Home blood pressure in poorly controlled hypertension: relationship with ambulatory blood pressure and organ damage

Martínez, María A., Sancho, Teresa, García, Pilar, Moreno, Pilar, Rubio, José M., Palau, Francisco J., Antón, José L., Cirujano, Francisco J., Sanz, José, Puig, Juan G. · 2006 · Blood Pressure Monitoring
Cited by 39

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: (1) To assess whether home blood pressure measurement is a reliable alternative to ambulatory blood pressure monitoring for the evaluation of treated patients with inadequate blood pressure control at the clinic; and (2) to evaluate the relationship between home blood pressure and several target-organ damage markers. BASIC METHODS: A cross-sectional study was performed in 225 treated hypertensive patients with persistently high blood pressure values at the clinic (systolic blood pressure 140 mmHg and/or diastolic blood pressure 90 mmHg). All study participants underwent clinic blood pressure measurement, 24-h ambulatory blood pressure and home blood pressure monitoring. A subgroup of patients underwent the following procedures: carotid echography (n=74), microalbuminuria determination (n=88) and echocardiography (n=43). We defined out-of-clinic normotension as an average ambulatory or home blood pressure less than 135 mmHg (systolic) and 85 mmHg (diastolic). MAIN RESULTS: The sensitivity, specificity and positive and negative predictive values of the home blood pressure method for predicting out-of-clinic normotension (with the ambulatory method used as reference), expressed as percentages, were 50, 87, 64 and 79%, respectively. Systolic home blood pressure correlated significantly with left ventricular mass (r=0.33, P<0.05) and microalbuminuria (r=0.24, P<0.05). Similar correlation coefficients were found for systolic ambulatory blood pressure (r=0.32, P<0.05 and r=0.24, P<0.05, respectively). Clinic blood pressure did not correlate with either left ventricular mass or microalbuminuria (r=0.19, P=0.09 and r=0.19, P=0.24, respectively). Diastolic home blood pressure, but not ambulatory blood pressure, correlated negatively with mean carotid intima-media thickness (r=-0.27, P<0.05). CONCLUSION: Our results suggest that, in patients with poorly controlled hypertension at the clinic, home blood pressure represents a complementary test rather than an alternative to ambulatory blood pressure, and correlates with several target-organ damage markers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.mbp.0000209073.30708.e1

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 39

Metadata

Authors
Martínez, M. A., Sancho, T., García, P., Moreno, P., Rubio, J. M., Palau, F. J., Antón, J. L., Cirujano, F. J., Sanz, J., & Puig, J. G.
Venue
Blood Pressure Monitoring
Published
2006-08
Volume
11
Issue
4
Pages
207-213
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2062999532
Cited by
39
References
4
FWCI
3.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Home blood pressure in poorly controlled hypertension: relationship with ambulatory blood pressure and organ damage. https://app.cochat.ai/papers/10.1097/01.mbp.0000209073.30708.e1
The paper
Martínez, M. A., Sancho, T., García, P., Moreno, P., Rubio, J. M., Palau, F. J., Antón, J. L., Cirujano, F. J., Sanz, J., & Puig, J. G. (2006). Home blood pressure in poorly controlled hypertension: relationship with ambulatory blood pressure and organ damage. Blood Pressure Monitoring. https://doi.org/10.1097/01.mbp.0000209073.30708.e1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.