CoChat

Extracting oscillometric pulses from the cuff pressure: does it affect the pressures determined by oscillometric blood pressure monitors?

Amoore, John N. · 2006 · Blood Pressure Monitoring
Cited by 32

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Oscillometric noninvasive blood pressure measurement devices determine the pressures by analysing the relationship between the pressure in an occluding cuff and low-amplitude pressure pulses (oscillometric pulses) induced in the cuff by the arterial pressure wave. This paper examines the effects on the pulses and oscillometric pulse amplitude envelope of the filters that extract the pulses from the cuff pressure. METHODS: The cuff pressure and oscillometric pulses extracted by the filter were recorded from a Critikon DINAMAP and a Datex Cardiocap, chosen because of accessibility of the filtered and unfiltered signals. The unfiltered oscillometric pulses were determined by subtracting the cuff pressure from a baseline constructed to represent either the Critikon's step deflation cuff pressure or the Datex's gradual pressure decrease. Waveforms were recorded from a noninvasive blood pressure test simulator and three volunteers. CONCLUSIONS: The filter alters the shape of oscillometric pulses causing a shift in the oscillometric pulse amplitude envelope drawn from the filtered pulses compared with that drawn from the unfiltered pulses in human subjects, but not the test simulator. The pulse shape distortion is dependent on the filter characteristics and the oscillometric pulse shape. Further work is required to explore whether this may help explain why simulators with artificial waveforms cannot validate noninvasive blood pressure monitors and why noninvasive blood pressure monitors may not be accurate in all patient groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.mbp.0000217999.04592.7c

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 32

Metadata

Authors
Amoore, J. N.
Venue
Blood Pressure Monitoring
Published
2006-10
Volume
11
Issue
5
Pages
269-279
ISSN
1359-5237 (ISSN-L)
OpenAlex
W1984675457
Cited by
32
References
5
FWCI
0.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Extracting oscillometric pulses from the cuff pressure: does it affect the pressures determined by oscillometric blood pressure monitors? https://app.cochat.ai/papers/10.1097/01.mbp.0000217999.04592.7c
The paper
Amoore, J. N. (2006). Extracting oscillometric pulses from the cuff pressure: does it affect the pressures determined by oscillometric blood pressure monitors? Blood Pressure Monitoring. https://doi.org/10.1097/01.mbp.0000217999.04592.7c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.