CoChat

Cochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array

Hillman, Todd, Badi, Arun N., Normann, Richard A., Kertesz, Tom, Shelton, Clough · 2003 · Otology & Neurotology
Cited by 52

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

HYPOTHESIS: An array of penetrating microelectrodes can be implanted into the cochlear nerve to produce stable evoked responses with important electrophysiologic advantages over conventional electrode technology. BACKGROUND: A totally implantable cochlear implant system would benefit from new electrode technology that lowers the current required for stimulation. Modern cochlear implant arrays placed in the scala tympani have an appreciable distance between the electrodes and the cochlear nerve, the site of intended stimulation. This distance can create the problem of cross-talk, limiting the number of electrodes that can represent discrete frequencies over a given length as well as significantly increasing stimulation thresholds and producing nonfocal stimulation of the fibers in the nerve. An electrode in direct contact with neurons in the cochlear nerve could reduce these problems. The Utah Electrode Array is a novel, three-dimensional, penetrating electrode array intended for direct neural stimulation with the potential ability to implant up to 200 electrodes directly into the cochlear nerve. METHODS: Arrays containing 6 to 19 electrodes were implanted acutely into six separate cat cochlear nerves for analysis. Thresholds and input/output functions were measured with electrically induced auditory brainstem responses. RESULTS: Current injections in 38 of 70 implanted electrodes produced stable brainstem responses after implantation. The median threshold was 15 microA. CONCLUSIONS: An array of penetrating electrodes can be implanted into the cochlear nerve and used to evoke brainstem responses. The responses are of low threshold and are stable. Arrays of electrodes, inserted into auditory nerve, could form the neural interfaces for the next generation of auditory prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00129492-200309000-00013

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 52

Metadata

Authors
Hillman, T., Badi, A. N., Normann, R. A., Kertesz, T., & Shelton, C.
Venue
Otology & Neurotology
Published
2003-09
Volume
24
Issue
5
Pages
764-768
ISSN
1531-7129 (ISSN-L)
OpenAlex
W2065507340
Cited by
52
References
2
FWCI
1.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array. https://app.cochat.ai/papers/10.1097/00129492-200309000-00013
The paper
Hillman, T., Badi, A. N., Normann, R. A., Kertesz, T., & Shelton, C. (2003). Cochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array. Otology & Neurotology. https://doi.org/10.1097/00129492-200309000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.