Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer Screening
The DOI matches its Crossref record.
Abstract
Previous trials, limited in many respects, have not found digital mammography to be significantly more accurate than the standard film method. A total of 42,760 asymptomatic women seen at 33 sites in the United States and Canada requested screening mammography and underwent both film and digital examinations. Two radiologists independently interpreted the film and digital mammograms. All participants either had breast biopsy within 15 months after evaluation or had a follow-up mammogram 10 months or longer after entry to the study. The results were assessed by receiver operating characteristic analysis. Both digital and film mammograms were positive in 0.5% of women. Another 2.2% had only a positive digital study, whereas 1.9% had only a positive film study. In the remaining women, approximately 95% of the total, both imaging studies were negative. Of 335 breast cancers diagnosed within 455 days after entry to the study, approximately three fourths were found within a year after evaluation. There were no substantial differences between the digital and film findings with respect to histology or stage of disease. The area under the curve was similar for the 2 studies and was not influenced by race or the risk of breast cancer. Digital mammography did, however, perform significantly better than the film method in women less than 50 years of age, in those having heterogeneously dense or very dense breasts, and premenopausal or perimenopausal women. The digital and film methods performed equally well in women age 50 years and older, those with fatty breasts or scattered fibroglandular densities, and those who were postmenopausal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Mammographic Density and the Risk and Detection of Breast Cancer
Boyd, N. F., Guo, H., Martin, L. J., Sun, L., Stone, J., Fishell, E., Jong, R. A., Hislop, G., Chiarelli, A., Minkin, S., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa062790 · Cited by 2,478
Self-citationBerg, W. A. (2008) · JAMA · doi:10.1001/jama.299.18.2151 · Cited by 1,526
MRI Evaluation of the Contralateral Breast in Women with Recently Diagnosed Breast Cancer
Lehman, C. D., Gatsonis, C., Kuhl, C. K., Hendrick, R. E., Pisano, E. D., Hanna, L., Peacock, S., Smazal, S. F., Maki, D. D., Julian, T. B., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065447 · Cited by 945
Self-citationFass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Lee, C. H., Dershaw, D. D., Kopans, D., Evans, P., Monsees, B., Monticciolo, D., Brenner, R. J., Bassett, L., Berg, W., Feig, S., et al. (2010) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2009.09.022 · Cited by 809
Self-citationLehman, C. D., Arao, R. F., Sprague, B. L., Lee, J. M., Buist, D. S. M., Kerlikowske, K., Henderson, L. M., Onega, T., Tosteson, A. N. A., Rauscher, G. H., et al. (2017) · Radiology · doi:10.1148/radiol.2016161174 · Cited by 665
American Cancer Society Guidelines for the Early Detection of Cancer, 2006
Smith, R. A., Cokkinides, V., & Eyre, H. J. (2006) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.56.1.11 · Cited by 639
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
Early Diagnosis of Breast Cancer
Wang, L. (2017) · Sensors · doi:10.3390/s17071572 · Cited by 549
Evaluation of diagnostic tests when there is no gold standard. A review of methods
Rutjes, A., Reitsma, J., Coomarasamy, A., Khan, K., & Bossuyt, P. (2007) · Health Technology Assessment · doi:10.3310/hta11500 · Cited by 524
Kelly, K. M., Dean, J., Comulada, W. S., & Lee, S.-J. (2010) · European Radiology · doi:10.1007/s00330-009-1588-y · Cited by 497
Pisano, E. D., Hendrick, R. E., Yaffe, M. J., Baum, J. K., Acharyya, S., Cormack, J. B., Hanna, L. A., Conant, E. F., Fajardo, L. L., Bassett, L. W., et al. (2008) · Radiology · doi:10.1148/radiol.2461070200 · Cited by 464
Self-citationCerussi, A., Shah, N., Hsiang, D., Durkin, A., Butler, J., & Tromberg, B. J. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2337546 · Cited by 421
Low target prevalence is a stubborn source of errors in visual search tasks.
Wolfe, J. M., Horowitz, T. S., Van Wert, M. J., Kenner, N. M., Place, S. S., & Kibbi, N. (2007) · Journal of Experimental Psychology: General · doi:10.1037/0096-3445.136.4.623 · Cited by 418
Hubbard, R. A., Kerlikowske, K., Flowers, C. I., Yankaskas, B. C., Zhu, W., & Miglioretti, D. L. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00004 · Cited by 414
Dedicated Breast CT: Initial Clinical Experience
Lindfors, K. K., Boone, J. M., Nelson, T. R., Yang, K., Kwan, A. L. C., & Miller, D. F. (2008) · Radiology · doi:10.1148/radiol.2463070410 · Cited by 351
Recommendations on screening for breast cancer in average-risk women aged 40-74 years
The Canadian Task Force on Preventive Health Care (2011) · Canadian Medical Association Journal · doi:10.1503/cmaj.110334 · Cited by 348
Andersson, I., Ikeda, D. M., Zackrisson, S., Ruschin, M., Svahn, T., Timberg, P., & Tingberg, A. (2008) · European Radiology · doi:10.1007/s00330-008-1076-9 · Cited by 343
Bevilacqua, J. L. B., Kattan, M. W., Fey, J. V., Cody, H. S., Borgen, P. I., & Van Zee, K. J. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.08.8013 · Cited by 342
Galloway, C. D., Valys, A. V., Shreibati, J. B., Treiman, D. L., Petterson, F. L., Gundotra, V. P., Albert, D. E., Attia, Z. I., Carter, R. E., Asirvatham, S. J., et al. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.0640 · Cited by 318
Ultrasound as the Primary Screening Test for Breast Cancer: Analysis From ACRIN 6666
Berg, W. A., Bandos, A. I., Mendelson, E. B., Lehrer, D., Jong, R. A., & Pisano, E. D. (2016) · Journal of the National Cancer Institute · doi:10.1093/jnci/djv367 · Cited by 309
Self-citationPlevritis, S. K., Munoz, D., Kurian, A. W., Stout, N. K., Alagoz, O., Near, A. M., Lee, S. J., van den Broek, J. J., Huang, X., Schechter, C. B., et al. (2018) · JAMA · doi:10.1001/jama.2017.19130 · Cited by 302
Doi, K. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r02 · Cited by 290
Using Resistin, glucose, age and BMI to predict the presence of breast cancer
Patrício, M., Pereira, J., Crisóstomo, J., Matafome, P., Gomes, M., Seiça, R., & Caramelo, F. (2018) · BMC Cancer · doi:10.1186/s12885-017-3877-1 · Cited by 277
Kerlikowske, K., Hubbard, R. A., Miglioretti, D. L., Geller, B. M., Yankaskas, B. C., Lehman, C. D., Taplin, S. H., Sickles, E. A., & for the Breast Cancer Surveillance Consortium (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00005 · Cited by 268
Cost-effectiveness of Screening BRCA1/2 Mutation Carriers With Breast Magnetic Resonance Imaging
Plevritis, S. K., Kurian, A. W., Sigal, B. M., Daniel, B. L., Ikeda, D. M., Stockdale, F. E., & Garber, A. M. (2006) · JAMA · doi:10.1001/jama.295.20.2374 · Cited by 260
Image-Detected Breast Cancer: State of the Art Diagnosis and Treatment
Silverstein, M. J., Lagios, M. D., Recht, A., Allred, C. D., Harms, S. E., Holland, R., Holmes, D. R., Hughes, L. L., Jackman, R. J., Julian, T. B., et al. (2005) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2005.05.032 · Cited by 256
Volatile biomarkers in the breath of women with breast cancer
Phillips, M., Cataneo, R. N., Saunders, C., Hope, P., Schmitt, P., & Wai, J. (2010) · Journal of Breath Research · doi:10.1088/1752-7155/4/2/026003 · Cited by 253
Management of an Inherited Predisposition to Breast Cancer
Robson, M., & Offit, K. (2007) · New England Journal of Medicine · doi:10.1056/nejmcp071286 · Cited by 252
Clinical validation of an autoantibody test for lung cancer
Boyle, P., Chapman, C. J., Holdenrieder, S., Murray, A., Robertson, C., Wood, W. C., Maddison, P., Healey, G., Fairley, G. H., Barnes, A. C., et al. (2011) · Annals of Oncology · doi:10.1093/annonc/mdq361 · Cited by 240
Evans, K. K., Birdwell, R. L., & Wolfe, J. M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064366 · Cited by 236
Deep Learning–Based Algorithm for Detecting Aortic Stenosis Using Electrocardiography
Kwon, J., Lee, S. Y., Jeon, K., Lee, Y., Kim, K., Park, J., Oh, B., & Lee, M. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.014717 · Cited by 224
Sprague, B. L., Stout, N. K., Schechter, C., van Ravesteyn, N. T., Cevik, M., Alagoz, O., Lee, C. I., van den Broek, J. J., Miglioretti, D. L., Mandelblatt, J. S., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0692 · Cited by 217
Breast density implications and supplemental screening
Vourtsis, A., & Berg, W. A. (2019) · European Radiology · doi:10.1007/s00330-018-5668-8 · Cited by 217
Lobbes, M. B. I., Lalji, U., Houwers, J., Nijssen, E. C., Nelemans, P. J., van Roozendaal, L., Smidt, M. L., Heuts, E., & Wildberger, J. E. (2014) · European Radiology · doi:10.1007/s00330-014-3154-5 · Cited by 210
Muduli, D., Dash, R., & Majhi, B. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102825 · Cited by 203
Cost-Effectiveness of Digital Mammography Breast Cancer Screening
Tosteson, A. N. A., Stout, N. K., Fryback, D. G., Acharyya, S., Herman, B. A., Hannah, L. G., Pisano, E. D., & for the DMIST Investigators* (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-1-200801010-00002 · Cited by 183
Self-citationBrandt, K. R., Scott, C. G., Ma, L., Mahmoudzadeh, A. P., Jensen, M. R., Whaley, D. H., Wu, F. F., Malkov, S., Hruska, C. B., Norman, A. D., et al. (2016) · Radiology · doi:10.1148/radiol.2015151261 · Cited by 183
Volumetric breast density affects performance of digital screening mammography
Wanders, J. O. P., Holland, K., Veldhuis, W. B., Mann, R. M., Pijnappel, R. M., Peeters, P. H. M., van Gils, C. H., & Karssemeijer, N. (2017) · Breast Cancer Research and Treatment · doi:10.1007/s10549-016-4090-7 · Cited by 166
Assessing Dynamic Breast Cancer Screening Policies
Maillart, L. M., Ivy, J. S., Ransom, S., & Diehl, K. (2008) · Operations Research · doi:10.1287/opre.1080.0614 · Cited by 163
Disparities in screening mammography services by race/ethnicity and health insurance
Rauscher, G. H., Allgood, K. L., Whitman, S., & Conant, E. (2012) · Journal of Women s Health · doi:10.1089/jwh.2010.2415 · Cited by 128
Self-citationKwon, J.-M., Kim, K.-H., Eisen, H. J., Cho, Y., Jeon, K.-H., Lee, S. Y., Park, J., & Oh, B.-H. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztaa015 · Cited by 82
Metadata
- Authors
- Pisano, E. D., Gatsonis, C., Hendrick, E., Yaffe, M., Baum, J. K., Acharyya, S., Conant, E. F., Fajardo, L. L., Bassett, L., D???Orsi, C., Jong, R., & Rebner, M.
- Venue
- Obstetrical & Gynecological Survey
- Published
- 2006-03
- Volume
- 61
- Issue
- 3
- Pages
- 178
- ISSN
- 0029-7828 (ISSN-L)
- OpenAlex
- W2568337645
- Cited by
- 482
- References
- 0
- FWCI
- 45.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.