Progressive Powered Lenses: the Minkwitz Theorem
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: The Minkwitz theorem, which can be proven to apply to the immediate surface surrounding a line of umbilics, states that astigmatism perpendicular to the line changes twice as quickly as the rate of change of power along the line. Our objective is to test how the Minkwitz theorem applies to the design of progressive addition lenses (PALs). METHOD: Our primary investigation of the astigmatism/power rate relationship used Hoya Tact lenses because they have a relatively large central region with horizontal spherical equivalent power contours and vertical astigmatism power contours. Other PALs were used for subsequent analysis. Lenses were measured with a Rotlex Class Plus lens analyzer. RESULTS: Zone widths in the central region of the Tact lenses exceeded those predicted by the Minkwitz theorem. Above and below this region, zone widths were narrower than predicted. When averaged along the entire corridor, zone widths approximated the Minkwitz theorem. For other PALs, the measured zone widths exceed Minkwitz theorem in the top (distance) and middle (intermediate) corridor but fell short in the lower (near) corridor. Likewise, on average along the entire corridor, they approximate the Minkwitz theorem. CONCLUSIONS: Although the Minkwitz theorem must apply exactly to the immediate locale of an umbilic, deviations from Minkwitz can occur within 2 mm of the corridor. Several factors enable enough local deviation from the Minkwitz theorem to "steer" the astigmatism and affect its magnitude in the peripheral portions of a lens. Although the Minkwitz relationship may be altered in some regions of the corridor, there is a global component to the Minkwitz prediction that applies to PALs. On a global level, the gains and losses of astigmatism along the corridor with respect to the Minkwitz prediction have strong tendency to cancel one another. In the end, it appears the unwanted astigmatism associated with a given power change along a given distance can be redistributed but probably not reduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progressive addition lenses — matching the specific lens to patient needs
Sheedy, J. E. (2004) · Optometry - Journal of the American Optometric Association · doi:10.1016/s1529-1839(04)70021-4 · Cited by 82
Self-citation
Cited by
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00245.x · Cited by 114
Progress in the spectacle correction of presbyopia. Part 2: modern progressive lens technologies
Meister, D. J., & Fisher, S. W. (2008) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2008.00246.x · Cited by 87
Optical performance of progressive addition lenses (PALs) with astigmatic prescription
De Lestrange-Anginieur, E., & Kee, C. S. (2021) · Scientific Reports · doi:10.1038/s41598-021-82697-0 · Cited by 9
Does visual acuity predict visual preference in progressive addition lenses?
Legras, R., Vincent, M., & Marin, G. (2023) · Journal of Optometry · doi:10.1016/j.optom.2022.04.003 · Cited by 7
Oscar, G.-E., Irene, S., & Raul, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-38446-6 · Cited by 2
Metadata
- Authors
- SHEEDY, J. E., CAMPBELL, C., KING-SMITH, E., & HAYES, J. R.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2005-10
- Volume
- 82
- Issue
- 10
- Pages
- 916-922
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2005554689
- Cited by
- 99
- References
- 1
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progressive Powered Lenses: the Minkwitz Theorem. https://app.cochat.ai/papers/10.1097/01.opx.0000181266.60785.c9
- The paper
- SHEEDY, J. E., CAMPBELL, C., KING-SMITH, E., & HAYES, J. R. (2005). Progressive Powered Lenses: the Minkwitz Theorem. Optometry and Vision Science. https://doi.org/10.1097/01.opx.0000181266.60785.c9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.