Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 489

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Compliance With Saliva Sampling Protocols: Electronic Monitoring Reveals Invalid Cortisol Daytime Profiles in Noncompliant Subjects

Kudielka, Brigitte M., Broderick, Joan E., Kirschbaum, Clemens·2003·Psychosomatic Medicine

Abstract

OBJECTIVE: Ambulatory saliva collections for subsequent analysis of free cortisol levels are now frequently applied to measure adrenocortical activity in healthy subjects and patient populations. Despite the prime importance of accurate timing of saliva collection outside the laboratory, no data are available on the compliance of study participants following a given sampling protocol. This study investigated how accurately subjects adhered to the instructions to collect six saliva samples throughout 1 day. METHODS: Subjects were instructed to collect six saliva samples throughout 1 day (directly after awakening, 30 minutes after awakening, 11 AM, 3 PM, 8 PM, 10 PM). Objective compliance was measured using an electronic monitoring device given to the subjects either with ("informed" N = 23) or without ("noninformed" N = 24) their knowledge of the nature of the device. Data on subjective compliance were obtained by self-report. RESULTS: Thirty-one subjects (74%) were found to comply with the sampling instructions, and 11 (26%) failed at least once to obtain the saliva sample at the correct time of day. Nine of the 11 noncompliant subjects (82%) had two or more noncompliant samples. Fifty-five percent (6 of 11) of the noncompliant subjects took sample 2 outside the sampling window. The circadian cortisol profile differed significantly between compliant and noncompliant subjects (F = 7.98, p =.007). The most important effect of compliance was seen in the rise of cortisol at awakening. Compliant subjects showed a robust increase, whereas noncompliant individuals had only minimal changes from baseline at 30 minutes after awakening (t = 2.89, p =.007). Thus the steepness of the circadian cortisol decline was greater for compliant subjects (t = 2.10, p =.043). Furthermore, the informed group adhered more closely to the sampling protocol than the noninformed subjects (p =.001). Self-reported compliance also differed significantly between study groups (p =.03). In the noninformed group, self-reported sampling accuracy was significantly higher than objectively measured compliance (p =.03); the two measures were similar in the informed group (p = NS). CONCLUSIONS: A significant number of subjects did not obtain saliva samples reliably in an ambulatory setting. This can partially invalidate the cortisol results and mask potential differences between subject groups of interest. We therefore recommend the use of electronic monitoring devices or other suitable methods and that study participants be informed about the device when ambulatory saliva collection is performed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.psy.0000058374.50240.bf

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 52 references

Cited by

See all 489

Metadata

Authors
Kudielka, B. M., Broderick, J. E., & Kirschbaum, C.
Venue
Psychosomatic Medicine
Published
2003-03
Volume
65
Issue
2
Pages
313-319
ISSN
0033-3174 (ISSN-L)
OpenAlex
W2165340302
Cited by
489
References
52
FWCI
7.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compliance With Saliva Sampling Protocols: Electronic Monitoring Reveals Invalid Cortisol Daytime Profiles in Noncompliant Subjects. https://app.cochat.ai/papers/10.1097/01.psy.0000058374.50240.bf
The paper
Kudielka, B. M., Broderick, J. E., & Kirschbaum, C. (2003). Compliance With Saliva Sampling Protocols: Electronic Monitoring Reveals Invalid Cortisol Daytime Profiles in Noncompliant Subjects. Psychosomatic Medicine. https://doi.org/10.1097/01.psy.0000058374.50240.bf

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.