High-Resolution Whole-Body Magnetic Resonance Image Tumor Staging With the Use of Parallel Imaging Versus Dual-Modality Positron Emission Tomography–Computed Tomography: Experience on a 32-Channel System
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The objective of this study was to compare the accuracy in staging of various malignant tumors with whole-body magnetic resonance imaging (WB-MRI) using parallel imaging (PAT) and positron emission tomography-computed tomography (PET-CT). MATERIALS AND METHODS: In a prospective study, 41 patients withoncologic diseases underwent [F]-fluoro-2-deoxy-D-glucose PET-CT for tumor staging and WB-MRI on a 32-channel-scanner with the use of PAT. Coronal T1w and STIR sequences at 5 body levels, axial HASTE imaging of the lung, and contrast-enhanced T1w sequences of the liver, brain, and abdomen were performed. TNM stage was assessed for both modalities in a separate consensus reading using histologic results and radiologic follow up within 6 months as the standard of reference. RESULTS: Three primary and 4 recurrent tumors were detected; one recurrent tumor was missed with WB-MRI. Sixty benign and 60 malignant lymph nodes were detected with a sensitivity of 98% and specificity of 83% for PET-CT and 80%/75% for WB-MRI, respectively. One hundred ninety-one malignant and 77 benign distant lesions were detected with a sensitivity/specificity of 82% for PET-CT and 96%/82% for WB-MRI. Accuracy for correct TNM staging was 96% for PET-CT and 91% for WB-MRI. CONCLUSION: WB-MRI and PET-CT are reliable imaging modalities for tumor staging. WB-MRI is highly sensitive in detecting distant metastases; PET-CT is superior in lymph node staging. PAT makes high-resolution WB-MRI feasible within less than 1 hour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“The image reconstruction in principal can take place by 2 different algorithms: either by calculation of the missing k-space lines before Fourier transformation (SMASH or GRAPPA) or by later fusion of the generated incomplete images (SENSE).(17,18) The GRAPPA reconstruction algorithm was applied for the examinations p…”
MethodGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 1×
“The image reconstruction in principal can take place by 2 different algorithms: either by calculation of the missing k-space lines before Fourier transformation (SMASH or GRAPPA) or by later fusion of the generated incomplete images (SENSE).(17,18) The GRAPPA reconstruction algorithm was applied for the examinations p…”
MethodRoemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322 · cited 1×
“Another important development has been the introduction of parallel imaging techniques (PATs); the principle of parallel imaging is to use the spatial information from different elements of multiple independent radiofrequency receiver coils to reconstruct the image.(16) This process substantially reduces the individua…”
BackgroundA combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Lardinois, D., Weder, W., Hany, T. F., Kamel, E. M., Korom, S., Seifert, B., von Schulthess, G. K., & Steinert, H. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022136 · Cited by 1,416
Preoperative Staging of Non–Small-Cell Lung Cancer with Positron-Emission Tomography
Pieterman, R. M., van Putten, J. W. G., Meuzelaar, J. J., Mooyaart, E. L., Vaalburg, W., Koëter, G. H., Fidler, V., Pruim, J., & Groen, H. J. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200007273430404 · Cited by 1,111 · cited 1×
“Whole-body PET using FDG is an imaging modality enabling to detect cancerous disease by tracing increased accumulation of FDG in tumor lesions.(4,5) Prospectively designed studies could show a correct change of the M-stage in 10% of all cases when (18)F -fluoro-2-deoxy-Dglucose (FDG) positron emission tomography (PET)…”
MethodWhole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
Antoch, G. (2003) · JAMA · doi:10.1001/jama.290.24.3199 · Cited by 551 · cited 13×
“In the published literature, only one other study group systematically compared WB-MRI with PET-CT for tumor staging.(29) Antoch et al examined 98 patients and found an acceptable accuracy of 77% for correct overall TNM staging with PET-CT; however, results for WB-MRI differed considerably with 54%.”
ResultInfluentialYEUNG, H. W. D., Grewal, R. K., Gönen, M., Schöder, H. M., & Larson, S. M. (2003) · PubMed · Cited by 370
Upper abdominal lymph nodes: criteria for normal size determined with CT.
Dorfman, R. E., Alpern, M. B., Gross, B. H., & Sandler, M. A. (1991) · Radiology · doi:10.1148/radiology.180.2.2068292 · Cited by 348
Staging non—small cell lung cancer by whole-body positron emission tomographic imaging
Valk, P. E., Pounds, T. R., Hopkins, D. M., Haseman, M. K., Hofer, G. A., Greiss, H. B., Myers, R. W., & Lutrin, C. L. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00752-0 · Cited by 316 · cited 2×
“Whole-body PET using FDG is an imaging modality enabling to detect cancerous disease by tracing increased accumulation of FDG in tumor lesions.4,5 Prospectively designed studies could show a correct change of the M-stage in 10% of all cases when 18F -fluoro-2-deoxy-Dglucose (FDG) positron emission tomography (PET) was…”
Background
Cited by
PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418
Latest Advances in Molecular Imaging Instrumentation
Pichler, B. J., Wehrl, H. F., & Judenhofer, M. S. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.045880 · Cited by 223
“The advent of parallel imaging techniques, such as generalized autocalibrating, partially parallel acquisitions (143) and sensitivity encoding (144) has accelerated image acquisition times, thus allowing whole-body MRI examinations with high spatial resolution (145).”
BackgroundOncologic PET/MRI, Part 1: Tumors of the Brain, Head and Neck, Chest, Abdomen, and Pelvis
Buchbender, C., Heusner, T. A., Lauenstein, T. C., Bockisch, A., & Antoch, G. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105338 · Cited by 214
“There is also evidence that the lung-tissue contrast of MRI has the potential to be further improved by certain sequences—that is, half-Fourier, single-shot, turbo spin echo sequences (21).”
BackgroundPfannenberg, C., Aschoff, P., Schanz, S., Eschmann, S. M., Plathow, C., Eigentler, T. K., Garbe, C., Brechtel, K., Vonthein, R., Bares, R., et al. (2007) · European Journal of Cancer · doi:10.1016/j.ejca.2006.11.014 · Cited by 191
Yi, C. A., Shin, K. M., Lee, K. S., Kim, B.-T., Kim, H., Kwon, O. J., Choi, J. Y., & Chung, M. J. (2008) · Radiology · doi:10.1148/radiol.2482071822 · Cited by 177
Metadata
- Authors
- Schmidt, G. P., Baur-Melnyk, A., Herzog, P., Schmid, R., Tiling, R., Schmidt, M., Reiser, M. F., & Schoenberg, S. O.
- Venue
- Investigative Radiology
- Published
- 2005-12
- Volume
- 40
- Issue
- 12
- Pages
- 743-753
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W1975666948
- Cited by
- 158
- References
- 21
- FWCI
- 10.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.