Navigation with Electromagnetic Tracking for Interventional Radiology Procedures: A Feasibility Study
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy assessment protocols for electromagnetic tracking systems
Frantz, D. D., Wiles, A. D., Leis, S. E., & Kirsch, S. R. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/14/314 · Cited by 173 · cited 2×
“However, this root mean square measure of error is not an accurate reflection of overall system accuracy because it may hide underlying error distribution (2).”
BackgroundMagnetically tracked bone screws for image guided intervention
Glossop, N., Cleary, K., Burgess, J. E., & Corral, G. (2004) · International Congress Series · doi:10.1016/j.ics.2004.03.357 · Cited by 2 · cited 2×
“Electromagnetic tracking can provide spatial navigation information from previously acquired images (Fig 1) (1-11).”
BackgroundSelf-citation
Cited by
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Electromagnetic Tracking in Medicine—A Review of Technology, Validation, and Applications
Franz, A. M., Haidegger, T., Birkfellner, W., Cleary, K., Peters, T. M., & Maier-Hein, L. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2321777 · Cited by 504
Self-citationImage-guidance for surgical procedures
Peters, T. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/r01 · Cited by 249
Tatli, S., Gerbaudo, V. H., Mamede, M., Tuncali, K., Shyn, P. B., & Silverman, S. G. (2010) · Radiology · doi:10.1148/radiol.10090931 · Cited by 103
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
Computer-assisted navigation applied to fetal cardiac intervention
Emery, S. P., Kreutzer, J., Sherman, F. R., Fujimoto, K. L., Jaramaz, B., Nikou, C., Tobita, K., & Keller, B. B. (2007) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.145 · Cited by 15
“3 mm at a distance of 100–500 mm from sensor to detector (Figure 7) (25,31,38).”
Background
Metadata
- Authors
- Wood, B. J., Zhang, H., Durrani, A., Glossop, N., Ranjan, S., Lindisch, D., Levy, E., Banovac, F., Borgert, J., Krueger, S., Kruecker, J., Viswanathan, A., & Cleary, K.
- Venue
- Journal of Vascular and Interventional Radiology
- Publisher
- Elsevier BV
- Published
- 2005-04
- Volume
- 16
- Issue
- 4
- Pages
- 493-505
- ISSN
- 1051-0443 (ISSN-L)
- OpenAlex
- W2126201524
- Cited by
- 227
- References
- 2
- FWCI
- 15.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.