CoChat

Refinement of the Automated Method for Human Islet Isolation and Presentation of a Closed System for In Vitro Islet Culture

Goto, Masafumi, Eich, Torsten M., Felldin, Marie, Foss, Aksel, Källen, Ragnar, Salmela, Kaija, Tibell, Annika, Tufveson, Gunnar, Fujimori, Keisei, Engkvist, Margareta, Korsgren, Olle · 2004 · Transplantation
Cited by 223

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The procedure of human islet isolation needs further optimization and standardization. Here, we describe techniques to enhance enzymatic digestion and minimize mechanical forces during the digestion process. The isolation protocol has also been modified to meet current GMP (cGMP) standards. Moreover, the impact of donor- and process-related factors was correlated to the use of islets for clinical transplantation. METHODS: One hundred twelve standardized consecutive islet isolations were evaluated. Metyltioninklorid and indermil (topical tissue adhesive) were applied to detect leakage of collagenase injected and to repair the damaged pancreatic glands. The effects of dye and glue were evaluated in terms of islet yield, islet function using the perifusion assay, and success rate of the isolation. To analyze key factors for successful isolations, both univariate and multivariate regression analysis were performed. RESULTS: Both Metyltioninklorid and Indermil were effective to prevent leakage of enzyme solutions from the pancreatic glands. Both islet yield and success rate were higher when these tools were applied (4,516.1+/-543.0 vs. 3,447.7+/-323.5, P=0.02; 50.0% vs. 21.3%, P=0.02, respectively). No adverse effects on islet function or collagenase activity were observed. Multivariate regression analysis identified the maximal recorded amylase >100 U/L (P=0.026), BMI (P=0.03), and the use of catecholamine (P=0.04) as crucial donor-related factors. In addition, cold ischemia time (P=0.005), the dissection procedure using whole glands with duodenum (P=0.02), and the local procurement team (P=0.03) were identified as crucial isolation-related variables. CONCLUSIONS: A standardized technique of islet isolation is presented applying novel means to improve enzymatic digestion and to meet cGMP standards.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.tp.0000140882.53773.dc

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

Metadata

Authors
Goto, M., Eich, T. M., Felldin, M., Foss, A., Källen, R., Salmela, K., Tibell, A., Tufveson, G., Fujimori, K., Engkvist, M., & Korsgren, O.
Venue
Transplantation
Published
2004-11-15
Volume
78
Issue
9
Pages
1367-1375
ISSN
0041-1337 (ISSN-L)
OpenAlex
W2066795948
Cited by
223
References
18
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.