The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Protective versus Conventional Ventilation for Surgery: A Systematic Review and Individual Patient Data Meta-analysis
Open accessAbstract
AbstractAbstract: This individual patient meta-analysis of 2,127 patients ventilated under general anesthesia for surgery from 15 randomized controlled trials shows that intraoperative ventilation with low tidal volume protects against postoperative pulmonary complications, but further trials are necessary to define the role of intraoperative higher positive end–expiratory pressure to prevent postoperative pulmonary complications after major abdominal surgery. Background: Recent studies show that intraoperative mechanical ventilation using low tidal volumes (V T) can prevent postoperative pulmonary complications (PPCs). The aim of this individual patient data meta-analysis is to evaluate the individual associations between V T size and positive end–expiratory pressure (PEEP) level and occurrence of PPC. Methods: Randomized controlled trials comparing protective ventilation (low V T with or without high levels of PEEP) and conventional ventilation (high V T with low PEEP) in patients undergoing general surgery. The primary outcome was development of PPC. Predefined prognostic factors were tested using multivariate logistic regression. Results: Fifteen randomized controlled trials were included (2,127 patients). There were 97 cases of PPC in 1,118 patients (8.7%) assigned to protective ventilation and 148 cases in 1,009 patients (14.7%) assigned to conventional ventilation (adjusted relative risk, 0.64; 95% CI, 0.46 to 0.88; P < 0.01). There were 85 cases of PPC in 957 patients (8.9%) assigned to ventilation with low V T and high PEEP levels and 63 cases in 525 patients (12%) assigned to ventilation with low V T and low PEEP levels (adjusted relative risk, 0.93; 95% CI, 0.64 to 1.37; P = 0.72). A dose–response relationship was found between the appearance of PPC and V T size (R 2 = 0.39) but not between the appearance of PPC and PEEP level (R 2 = 0.08). Conclusions: These data support the beneficial effects of ventilation with use of low V T in patients undergoing surgery. Further trials are necessary to define the role of intraoperative higher PEEP to prevent PPC during nonopen abdominal surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Lung recruitment in patients with the acute respiratory distress syndrome.
Gattinoni, L., Caironi, P., Cressoni, M., Chiumello, D., Ranieri, V. M., Quintel, M., Russo, S., Patroniti, N., Cornejo, R., & Bugedo, G. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052052 · Cited by 1,548
Self-citationBriel, M., Meade, M., Mercat, A., Brower, R. G., Talmor, D., Walter, S. D., Slutsky, A. S., Pullenayegum, E., Zhou, Q., Cook, D., et al. (2010) · JAMA · doi:10.1001/jama.2010.218 · Cited by 1,467
Self-citationPrediction of Postoperative Pulmonary Complications in a Population-based Surgical Cohort
Canet, J., Gallart, L., Gomar, C., Paluzie, G., Vallès, J., Castillo, J., Sabaté, S., Mazo, V., Briones, Z., & Sanchis, J. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181fc6e0a · Cited by 1,459
Self-citationA trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434
Self-citationMortality after surgery in Europe: a 7 day cohort study
Pearse, R. M., Moreno, R. P., Bauer, P., Pelosi, P., Metnitz, P., Spies, C., Vallet, B., Vincent, J.-L., Hoeft, A., & Rhodes, A. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61148-9 · Cited by 1,355
Self-citationTidal ventilation at low airway pressures can augment lung injury.
Muscedere, J. G., Mullen, J. B., Gan, K., & Slutsky, A. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173774 · Cited by 1,244
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843
Self-citationGajic, O., Dara, S. I., Mendez, J. L., Adesanya, A. O., Festic, E., Caples, S. M., Rana, R., St. Sauver, J. L., Lymp, J. F., Afessa, B., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000133019.52531.30 · Cited by 739
Self-citation
Cited by
Postoperative pulmonary complications
Miskovic, A., & Lumb, A. B. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex002 · Cited by 1,123
Fernandez-Bustamante, A., Frendl, G., Sprung, J., Kor, D. J., Subramaniam, B., Martinez Ruiz, R., Lee, J.-W., Henderson, W. G., Moss, A., Mehdiratta, N., et al. (2017) · JAMA Surgery · doi:10.1001/jamasurg.2016.4065 · Cited by 653
Self-citationLow, D. E., Allum, W., De Manzoni, G., Ferri, L., Immanuel, A., Kuppusamy, M., Law, S., Lindblad, M., Maynard, N., Neal, J., et al. (2019) · World Journal of Surgery · doi:10.1007/s00268-018-4786-4 · Cited by 641
Young, C. C., Harris, E. M., Vacchiano, C., Bodnar, S., Bukowy, B., Elliott, R. R. D., Migliarese, J., Ragains, C., Trethewey, B., Woodward, A., et al. (2019) · British Journal of Anaesthesia · doi:10.1016/j.bja.2019.08.017 · Cited by 435
Self-citationMechanical Ventilation: State of the Art
Pham, T., Brochard, L. J., & Slutsky, A. S. (2017) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2017.05.004 · Cited by 377
Metadata
- Authors
- Serpa Neto, A., Hemmes, S. N. T., Barbas, C. S. V., Beiderlinden, M., Biehl, M., Binnekade, J. M., Canet, J., Fernandez-Bustamante, A., Futier, E., Gajic, O., Hedenstierna, G., Hollmann, M. W., Jaber, S., Kozian, A., Licker, M., Lin, W.-Q., Maslow, A. D., Memtsoudis, S. G., Reis Miranda, D., Moine, P., Ng, T., Paparella, D., Putensen, C., Ranieri, M., Scavonetto, F., Schilling, T., Schmid, W., Selmo, G., Severgnini, P., Sprung, J., Sundar, S., Talmor, D., Treschan, T., Unzueta, C., Weingarten, T. N., Wolthuis, E. K., Wrigge, H., Gama de Abreu, M., Pelosi, P., Schultz, M. J., & for the PROVE Network Investigators
- Venue
- Anesthesiology
- Published
- 2015-07
- Volume
- 123
- Issue
- 1
- Pages
- 66-78
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1820839252
- Cited by
- 348
- References
- 39
- FWCI
- 27.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protective versus Conventional Ventilation for Surgery: A Systematic Review and Individual Patient Data Meta-analysis. https://app.cochat.ai/papers/10.1097/aln.0000000000000706
- The paper
- Serpa Neto, A., Hemmes, S. N. T., Barbas, C. S. V., Beiderlinden, M., Biehl, M., Binnekade, J. M., Canet, J., Fernandez-Bustamante, A., Futier, E., Gajic, O., Hedenstierna, G., Hollmann, M. W., Jaber, S., Kozian, A., Licker, M., Lin, W.-Q., Maslow, A. D., Memtsoudis, S. G., Reis Miranda, D., . . . for the PROVE Network Investigators. (2015). Protective versus Conventional Ventilation for Surgery: A Systematic Review and Individual Patient Data Meta-analysis. Anesthesiology. https://doi.org/10.1097/aln.0000000000000706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.