Airway Changes during Labor and Delivery
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Background: There are no prospective studies that evaluated airway changes during labor. The purpose of this study was to evaluate airway changes in women undergoing labor and delivery. Methods: Two studies were undertaken to evaluate airway changes during labor. The first study used the conventional Samsoon modification of the Mallampati airway class. The airway was photographed at the onset and the end of labor. Women with class 4 airways were excluded from initial participation. In the second study, upper airway volumes were measured using acoustic reflectometry at the onset and the conclusion of labor. Acoustic reflectometry software computed the values for the components of upper airway, oral volume, and pharyngeal volume. Results: In study 1 (n = 61), there was a significant increase in airway class from prelabor to postlabor (P < 0.001). The airway increased one grade higher in 20 (33%) and two grades higher in 3 (5%) after labor. At the end of labor, there were 8 parturients with airway class 4 (P < 0.01) and 30 parturients with airway class 3 or class 4 (P < 0.001). In study 2 (n = 21), there were significant decreases in oral volume (n = 21; P < 0.05), and pharyngeal area (P < 0.05) and volume (P < 0.001) after labor and delivery. No correlation was observed between airway changes during labor and duration of labor, or fluids administered during labor in either study. Conclusion: Airways can change during labor. Therefore, a careful airway evaluation is essential just before administering anesthesia during labor rather than obtaining this information from prelabor data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471 · cited 1×
“Difficult or failed intubation after induction of general anesthesia for cesarean delivery remains the major contributing factor to anesthesiarelated maternal complications.(2,3) The first national study of anesthesia-related maternal mortality in the United States revealed that 52% of the deaths resulted from complic…”
BackgroundDifficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
Anesthesia-related Deaths during Obstetric Delivery in the United States. 1979–1990
Hawkins, J. L. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00047 · Cited by 554
Anesthetic and Obstetric Outcome in Morbidly Obese Parturients
Hood, D. D., & Dewan, D. M. (1993) · Anesthesiology · doi:10.1097/00000542-199312000-00011 · Cited by 436 · cited 1×
“The factors that are likely to increase the risk of difficult intubation are short neck, receding mandible, protruding maxillary incisors, and morbid obesity.(12,13) In the presence of these factors, changes in airway class during labor can potentially increase the cumulative risk of encountering difficulties in secur…”
BackgroundRelative Risk Analysis of Factors Associated with Difficult Intubation in Obstetric Anesthesia
Rocke, D. A., Murray, W. B., Rout, C. C., & Gouws, E. (1992) · Anesthesiology · doi:10.1097/00000542-199207000-00010 · Cited by 402 · cited 3×
“The relation between increasing airway classification and relative ease or difficulty at intubation in term pregnant women undergoing cesarean delivery during general anesthesia was studied by Rocke et al.(12) The relative risk of encountering difficult intubation in pregnant women with a class 3 airway was 7.”
BackgroundInfluentialIncrease in Mallampati score during pregnancy
PILKINGTON, S., CARLI, F., DAKIN, M. J., ROMNEY, M., DE WITT, K. A., DORé, C. J., & CORMACK, R. S. (1995) · British Journal of Anaesthesia · doi:10.1093/bja/74.6.638 · Cited by 353 · cited 6×
“Obvious factors such as enlarged breasts have been implicated, but simple maneuvers for dealing with these problems did not seem to decrease the incidence of difficult intubation.(5,7,8) There is no known bone or joint abnormalities in pregnancy that could pose difficulties during intubation.”
BackgroundResultInfluentialClinical sign to predict difficult tracheal intubation (hypothesis)
Mallampati, S. R. (1983) · Canadian Anaesthetists’ Society Journal · doi:10.1007/bf03013818 · Cited by 223 · cited 3×
“The Samsoon modification of the Mallampati airway classification is based on the visibility of the soft palate, faucial pillars, and uvula.(1,10) The visibility of structures is dependent on the relative capacity of the oropharyngeal cavity and the volume of the base of the tongue.”
BackgroundInfluentialA Series of Anesthesia-related Maternal Deaths in Michigan, 1985–2003
Mhyre, J. M., Riesner, M. N., Polley, L. S., & Naughton, N. N. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267592.34626.6b · Cited by 199
Difficult intubation in the parturient
Davies, J. M., Weeks, S. K., Crone, L.-A., & Pavlin, E. (1989) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03005419 · Cited by 93 · cited 1×
“Difficult or failed intubation after induction of general anesthesia for cesarean delivery remains the major contributing factor to anesthesiarelated maternal complications.(2,3) The first national study of anesthesia-related maternal mortality in the United States revealed that 52% of the deaths resulted from complic…”
BackgroundPharyngolaryngeal edema as a presenting symptom in preeclampsia.
Heller, P. J., Scheider, E. P., & Marx, G. F. (1983) · PubMed · Cited by 68
Cited by
Mushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Myatra, S. N., Shah, A., Kundra, P., Patwa, A., Ramkumar, V., Divatia, J. V., Raveendra, U. S., Shetty, S. R., Ahmed, S. M., Doctor, J. R., et al. (2016) · Indian Journal of Anaesthesia · doi:10.4103/0019-5049.195481 · Cited by 294
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Jones, P. M., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02007-0 · Cited by 184
Lamperti, M., Romero, C. S., Guarracino, F., Cammarota, G., Vetrugno, L., Tufegdzic, B., Lozsan, F., Macias Frias, J. J., Duma, A., Bock, M., et al. (2025) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000002069 · Cited by 159
Anesthesia for Nonobstetric Surgery: Maternal and Fetal Considerations
CHEEK, T. G., & BAIRD, E. (2009) · Clinical Obstetrics & Gynecology · doi:10.1097/grf.0b013e3181c11f60 · Cited by 158
Metadata
- Authors
- Kodali, B.-S., Chandrasekhar, S., Bulich, L. N., Topulos, G. P., & Datta, S.
- Venue
- Anesthesiology
- Published
- 2008-03-01
- Volume
- 108
- Issue
- 3
- Pages
- 357-362
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2171380701
- Cited by
- 226
- References
- 10
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.