Venous Function and Central Venous Pressure: A Physiologic Story
The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
The veins contain approximately 70% of total blood volume and are 30 times more compliant than arteries; therefore, changes in blood volume within the veins are associated with relatively small changes in venous pressure. The terms venous capacity, compliance, and stressed and unstressed volumes are defined. Decreases in flow into a vein are associated with decreases in intravenous pressure and volume, and vice versa. Changes in resistance in the small arteries and arterioles may affect venous return in opposite directions; this is explained by a two-compartment model: compliant (mainly splanchnic veins) and noncompliant (nonsplanchnic veins). Effects of intrathoracic and intraabdominal pressures on venous return and central venous pressure as well as the value of central venous pressure as a diagnostic variable are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Presynaptic regulation of the release of catecholamines.
Langer, S. Z. (1980) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)06843-7 · Cited by 1,490
MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.1.9903035 · Cited by 1,458
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Rowell, L. B. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199312000-00021 · Cited by 1,092
Passive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952
Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
The Pathophysiology of Aortic Cross-clamping and Unclamping
Gelman, S. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00027 · Cited by 603
Self-citationDetermination of Cardiac Output By Equating Venous Return Curves With Cardiac Response Curves
Guyton, A. C. (1955) · Physiological Reviews · doi:10.1152/physrev.1955.35.1.123 · Cited by 588
Venous Return at Various Right Atrial Pressures and the Normal Venous Return Curve
Guyton, A. C., Lindsey, A. W., Abernathy, B., & Richardson, T. (1957) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1957.189.3.609 · Cited by 544
Cited by
Malbrain, M. L. N. G., Marik, P. E., Witters, I., Cordemans, C., Kirkpatrick, A. W., Roberts, D. J., & Van Regenmortel, N. (2014) · Anestezjologia Intensywna Terapia · doi:10.5603/ait.2014.0060 · Cited by 702
Testani, J. M., Chen, J., McCauley, B. D., Kimmel, S. E., & Shannon, R. P. (2010) · Circulation · doi:10.1161/circulationaha.109.933275 · Cited by 680
Kinsella, S. M., Carvalho, B., Dyer, R. A., Fernando, R., McDonnell, N., Mercier, F. J., Palanisamy, A., Sia, A. T. H., Van de Velde, M., Vercueil, A., et al. (2018) · Anaesthesia · doi:10.1111/anae.14080 · Cited by 585
Congestion in heart failure: a contemporary look at physiology, diagnosis and treatment
Boorsma, E. M., ter Maaten, J. M., Damman, K., Dinh, W., Gustafsson, F., Goldsmith, S., Burkhoff, D., Zannad, F., Udelson, J. E., & Voors, A. A. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0379-7 · Cited by 365
Cannesson, M., Pestel, G., Ricks, C., Hoeft, A., & Perel, A. (2011) · Critical Care · doi:10.1186/cc10364 · Cited by 310
Fallick, C., Sobotka, P. A., & Dunlap, M. E. (2011) · Circulation: Heart Failure · doi:10.1161/circheartfailure.111.961789 · Cited by 296
A rational approach to fluid therapy in sepsis
Marik, P., & Bellomo, R. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aev349 · Cited by 261
Role of Volume Redistribution in the Congestion of Heart Failure
Fudim, M., Hernandez, A. F., & Felker, G. M. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.006817 · Cited by 199
“Consequently, the venous system contains 70% of total blood volume and is roughly 30 times more compliant to store blood than the arterial system.(12) The high vascular compliance allows veins to adapt to changes in the blood volume more easily.”
BackgroundJCS/JHFS 2025 Guideline on Diagnosis and Treatment of Heart Failure
Kitai, T., Kohsaka, S., Kato, T., Kato, E., Sato, K., Teramoto, K., Yaku, H., Akiyama, E., Ando, M., Izumi, C., et al. (2025) · Circulation Journal · doi:10.1253/circj.cj-25-0002 · Cited by 191
Gastrointestinal and Liver Issues in Heart Failure
Sundaram, V., & Fang, J. C. (2016) · Circulation · doi:10.1161/circulationaha.115.020894 · Cited by 173
“tors and therefore are responsive to the sympathetic nervous system.(12) In HF, the amplified sympathetic nervous system”
BackgroundIatrogenic salt water drowning and the hazards of a high central venous pressure
Marik, P. E. (2014) · Annals of Intensive Care · doi:10.1186/s13613-014-0021-0 · Cited by 168
“The MCFP in humans is normally in the range of 8 to 10 mmHg [80].”
BackgroundTestani, J. M., Brisco, M. A., Chen, J., McCauley, B. D., Parikh, C. R., & Tang, W. H. W. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.027 · Cited by 167
Jolley, M., Colan, S. D., Rhodes, J., & DiNardo, J. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000717 · Cited by 163
Obesity, venous capacitance, and venous compliance in heart failure with preserved ejection fraction
Sorimachi, H., Burkhoff, D., Verbrugge, F. H., Omote, K., Obokata, M., Reddy, Y. N. V., Takahashi, N., Sunagawa, K., & Borlaug, B. A. (2021) · European Journal of Heart Failure · doi:10.1002/ejhf.2254 · Cited by 124
Okamoto, L. E., Diedrich, A., Baudenbacher, F. J., Harder, R., Whitfield, J. S., Iqbal, F., Gamboa, A., Shibao, C. A., Black, B. K., Raj, S. R., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07199 · Cited by 79
“The splanchnic circulation contains a large and highly compliant venous bed, which normally stores ≈25% of the blood volume at rest,(26) and receives ≤25% of the resting cardiac output.(27) Splanchnic veins are highly innervated by sympathetic nerves and represent the largest blood volume reservoir in the human body.”
BackgroundResultPerner, A., & De Backer, D. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3223-x · Cited by 46
Smith, E. C., Diedrich, A., Raj, S. R., Gamboa, A., Shibao, C. A., Black, B. K., Peltier, A., Paranjape, S. Y., Biaggioni, I., & Okamoto, L. E. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.120.016196 · Cited by 16
Metadata
- Authors
- Gelman, S., Warner, D. S., & Warner, M. A.
- Venue
- Anesthesiology
- Published
- 2008-04-01
- Volume
- 108
- Issue
- 4
- Pages
- 735-748
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1968217945
- Cited by
- 575
- References
- 61
- FWCI
- 26.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.