Manual In-line Stabilization Increases Pressures Applied by the Laryngoscope Blade during Direct Laryngoscopy and Orotracheal Intubation
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Manual in-line stabilization (MILS) is recommended during direct laryngoscopy and intubation in patients with known or suspected cervical spine instability. Because MILS impairs glottic visualization, the authors hypothesized that anesthesiologists would apply greater pressure during intubations with MILS than without. Methods: Nine anesthetized and pharmacologically paralyzed patients underwent two sequential laryngoscopies and intubations, one with MILS and one without, in random order. A transducer array along a Macintosh 3 laryngoscope blade continuously measured applied pressures, and glottic view was characterized. Results: With MILS, glottic visualization was worse in six patients, and intubation failure occurred in two of these six patients. Maximum laryngoscope pressure at best glottic view was greater with MILS than without (717 +/- 339 mmHg vs. 363 +/- 121 mmHg, respectively; n = 8; P = 0.023). Other measures of pressure application also indicated comparable increases with MILS. Conclusion: Pressures applied to airway tissues by the laryngoscope blade are secondarily transmitted to the cervical spine and result in cranio-cervical motion. In the presence of cervical instability, impaired glottic visualization and secondary increases in pressure application with MILS have the potential to increase pathologic cranio-cervical motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Manoach, S., & Paladino, L. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.01.009 · Cited by 123 · cited 9×
“Intubation with MILS was associated with significantly less subluxation at the unstable segment compared to intubation with collar/head fixation.24 Notably, glottic visualization was significantly worse with collar/head fixation than with MILS.”
ResultInfluentialLeGrand, S. A., Hindman, B. J., Dexter, F., Weeks, J. B., & Todd, M. M. (2007) · Anesthesiology · doi:10.1097/01.anes.0000291461.62404.46 · Cited by 45 · cited 1×
“scope blade are secondarily transmitted to the cervical spine and result in cranio-cervical motion (extension).(18)”
BackgroundSelf-citation
Cited by
Thiboutot, F., Nicole, P. C., Trépanier, C. A., Turgeon, A. F., & Lessard, M. R. (2009) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-009-9089-7 · Cited by 86
Michailidou, M., O’Keeffe, T., Mosier, J. M., Friese, R. S., Joseph, B., Rhee, P., & Sakles, J. C. (2015) · World Journal of Surgery · doi:10.1007/s00268-014-2845-z · Cited by 79
Bathory, I., Frascarolo, P., Kern, C., & Schoettker, P. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2009.06075.x · Cited by 64
Maxillofacial trauma patient: coping with the difficult airway
Krausz, A. A., el-Naaj, I. A., & Barak, M. (2009) · World Journal of Emergency Surgery · doi:10.1186/1749-7922-4-21 · Cited by 44
Management of the airway in multitrauma
Dupanovic, M., Fox, H., & Kovac, A. (2010) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e3283360b4f · Cited by 39
Metadata
- Authors
- Santoni, B. G., Hindman, B. J., Puttlitz, C. M., Weeks, J. B., Johnson, N., Maktabi, M. A., & Todd, M. M.
- Venue
- Anesthesiology
- Published
- 2009-01-01
- Volume
- 110
- Issue
- 1
- Pages
- 24-31
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1995983413
- Cited by
- 133
- References
- 2
- FWCI
- 12.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Manual In-line Stabilization Increases Pressures Applied by the Laryngoscope Blade during Direct Laryngoscopy and Orotracheal Intubation. https://app.cochat.ai/papers/10.1097/aln.0b013e318190b556
- The paper
- Santoni, B. G., Hindman, B. J., Puttlitz, C. M., Weeks, J. B., Johnson, N., Maktabi, M. A., & Todd, M. M. (2009). Manual In-line Stabilization Increases Pressures Applied by the Laryngoscope Blade during Direct Laryngoscopy and Orotracheal Intubation. Anesthesiology. https://doi.org/10.1097/aln.0b013e318190b556
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.