The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Minimally Invasive Measurement of Cardiac Output during Surgery and Critical Care: A Meta-analysis of Accuracy and Precision
Abstract
When assessing the accuracy and precision of a new technique for cardiac output measurement, the commonly quoted criterion for acceptability of agreement with a reference standard is that the percentage error (95% limits of agreement/mean cardiac output) should be 30% or less. We reviewed published data on four different minimally invasive methods adapted for use during surgery and critical care: pulse contour techniques, esophageal Doppler, partial carbon dioxide rebreathing, and transthoracic bioimpedance, to assess their bias, precision, and percentage error in agreement with thermodilution. An English language literature search identified published papers since 2000 which examined the agreement in adult patients between bolus thermodilution and each method. For each method a meta-analysis was done using studies in which the first measurement point for each patient could be identified, to obtain a pooled mean bias, precision, and percentage error weighted according to the number of measurements in each study. Forty-seven studies were identified as suitable for inclusion: N studies, n measurements: mean weighted bias [precision, percentage error] were: pulse contour N = 24, n = 714: -0.00 l/min [1.22 l/min, 41.3%]; esophageal Doppler N = 2, n = 57: -0.77 l/min [1.07 l/min, 42.1%]; partial carbon dioxide rebreathing N = 8, n = 167: -0.05 l/min [1.12 l/min, 44.5%]; transthoracic bioimpedance N = 13, n = 435: -0.10 l/min [1.14 l/min, 42.9%]. None of the four methods has achieved agreement with bolus thermodilution which meets the expected 30% limits. The relevance in clinical practice of these arbitrary limits should be reassessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
5 retracted
Mayer, J., Boldt, J., Schöllhorn, T., Röhm, K. D., Mengistu, A. M., & Suttner, S. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/ael341 · Cited by 146
RetractedMayer, J., Boldt, J., Poland, R., Peterson, A. J., & Manecke, G. R. (2009) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2009.03.003 · Cited by 142
RetractedMayer, J., Boldt, J., Wolf, M. W., Lang, J. K., & Suttner, S. W. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318161964d · Cited by 101
RetractedSuttner, S. W., Schöllhorn, T., Boldt, J., Mayer, J., Röhm, K. D., Lang, K., & Piper, S. N. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0409-x · Cited by 88
RetractedMayer, J., Boldt, J., Beschmann, R., Stephan, A., & Suttner, S. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep133 · Cited by 24
RetractedPreferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & the PRISMA Group* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-4-200908180-00135 · Cited by 37,554
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Methods of Meta-Analysis: Correcting Error and Bias in Research Findings
Schmidt, F. L., & Hunter, J. E. (2015) · doi:10.4135/9781483398105 · Cited by 5,542
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04337-3 · Cited by 5,373
The Revised CONSORT Statement for Reporting Randomized Trials: Explanation and Elaboration
Altman, D. G., Schulz, K. F., Moher, D., Egger, M., Davidoff, F., Elbourne, D., Gøtzsche, P. C., Lang, T., & for the CONSORT Group (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-8-200104170-00012 · Cited by 3,835
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065
Critchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325
I. Using the Bland–Altman method to measure agreement with repeated measures
Myles, P. S., & Cui, J. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem214 · Cited by 620
Assessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.212 · Cited by 583
Stetz, C. W., Miller, R. G., Kelly, G. E., & Raffin, T. A. (1982) · PubMed · doi:10.1164/arrd.1982.126.6.1001 · Cited by 447
Zöllner, C., Haller, M., Weis, M., Mörstedt, K., Lamm, P., Kilger, E., & Goetz, A. E. (2000) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(00)90003-x · Cited by 375
Abbas, S. M., & Hill, A. G. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05233.x · Cited by 296
Della Rocca, G., Costa, M. G., Pompei, L., Coccia, C., & Pietropaoli, P. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.3.350 · Cited by 239
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
Funk, D. J., Moretti, E. W., & Gan, T. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31818ffd99 · Cited by 202
Button, D., Weibel, L., Reuthebuch, O., Genoni, M., Zollinger, A., & Hofer, C. K. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem188 · Cited by 176
Biancofiore, G., Critchley, L. A. H., Lee, A. S. Y., Bindi, L. M., Bisà, M., Esposito, M., Meacci, L., Mozzo, R., SIMONE, P. D., Urbani, L., et al. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen343 · Cited by 174
Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery
Sageman, W. S., Riffenburgh, R. H., & Spiess, B. D. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.29635 · Cited by 160
Albert, N. M., Hail, M. D., Li, J., & Young, J. B. (2004) · American Journal of Critical Care · doi:10.4037/ajcc2004.13.6.469 · Cited by 153
An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery
de Wilde, R. B. P., Schreuder, J. J., Berg, P. C. M. V. D., & Jansen, J. R. C. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05135.x · Cited by 149
Rocca, G. D., Costa, M. G., Coccia, C., Pompei, L., Marco, P. D., Vilardi, V., & Pietropaoli, P. (2003) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03018714 · Cited by 140
Drazner, M. H., Thompson, B. S., Rosenberg, P. B., Kaiser, P. A., Boehrer, J. D., Baldwin, B. J., Dries, D. L., & Yancy, C. W. (2002) · The American Journal of Cardiology · doi:10.1016/s0002-9149(02)02257-9 · Cited by 139
Accurate, Noninvasive Continuous Monitoring of Cardiac Output by Whole-Body Electrical Bioimpedance
Cotter, G., Moshkovitz, Y., Kaluski, E., Cohen, A. J., Miller, H. I., Goor, D. A., & Vered, Z. (2004) · CHEST Journal · doi:10.1378/chest.125.4.1431 · Cited by 135
A pilot assessment of the FloTracTM cardiac output monitoring system
Opdam, H. I., Wan, L., & Bellomo, R. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0410-4 · Cited by 124
Sander, M., Spies, C., Grubitzsch, H., Foer, A., Müller, M. C., & von Heymann, C. (2006) · Critical Care · doi:10.1186/cc5103 · Cited by 121
Validation of a new arterial pulse contour-based cardiac output device
de Waal, E. E. C., Kalkman, C. J., Rex, S., & Bühre, W. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000275429.45312.8c · Cited by 114
Costa, M. G., Rocca, G. D., Chiarandini, P., Mattelig, S., Pompei, L., Sainz‐Barriga, M., Reynolds, T. E., Cecconi, M., & Pietropaoli, P. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0878-6 · Cited by 113
McGee, W. T., Horswell, J. L., Calderon, J., Janvier, G., Severen, T. V., den Berghe, G. V., & Kozikowski, L. (2007) · Critical Care · doi:10.1186/cc6125 · Cited by 111
Zoremba, N., Bickenbach, J., Krauss, B., Rossaint, R., Kuhlen, R., & Schälte, G. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01445.x · Cited by 106
Botero, M., Kirby, D. S., Lobato, E. B., Staples, E. D., & Gravenstein, N. L. (2004) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.07.005 · Cited by 98
Bajorat, J., Hofmockel, R., Vagts, D. A., Janda, M., Pohl, B., Beck, C. E., & Noeldge‐Schomburg, G. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021505001717 · Cited by 96
Comparison of continuous cardiac output measurements in patients after cardiac surgery
Mielck, F., Bühre, W., Hanekop, G., Tirilomis, T., Hilgers, R., & Sonntag, H. (2003) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2003.49 · Cited by 92
Pulse contour analysis versus thermodilution in cardiac surgery patients
Rauch, H., Müller, M. C., Fleischer, F., Bauer, H., Martin, E., & Böttiger, B. W. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.460416.x · Cited by 91
Lack of agreement between thermodilution and carbon dioxide‐rebreathing cardiac output
Nilsson, L. B., Eldrup, N., & Berthelsen, P. G. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.045006680.x · Cited by 85
Felbinger, T. W., Reuter, D. A., Eltzschig, H. K., Bayerlein, J., & Goetz, A. E. (2005) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2004.06.013 · Cited by 84
Odenstedt, H., Stenqvist, O., & Lundin, S. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.460205.x · Cited by 77
Clinical Evaluation of the Non-Invasive Cardiac Output (NICO) Monitor in the Intensive Care Unit
van Heerden, P. V., Baker, S., Lim, S.-K., Weidman, C., & Bulsara, M. K. (2000) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0002800412 · Cited by 75
Rocco, M., Spadetta, G., Morelli, A., Dell’Utri, D., Porzi, P., Conti, G., & Pietropaoli, P. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2069-4 · Cited by 75
Pulse contour analysis after normothermic cardiopulmonary bypass in cardiac surgery patients
Sander, M., von Heymann, C., Foer, A., von Dossow, V., Grosse, J., Dushe, S., Konertz, W. F., & Spies, C. (2005) · Critical Care · doi:10.1186/cc3903 · Cited by 69
de Vaal, J. B., de Wilde, R. B. P., Berg, P. C. M. V. D., Schreuder, J. J., & Jansen, J. R. C. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei189 · Cited by 68
Garcia-Rodriguez, C., Pittman, J., Cassell, C. H., Sum-Ping, J., El-Moalem, H. E., Young, C., & Mark, J. B. (2002) · Critical Care Medicine · doi:10.1097/00003246-200210000-00004 · Cited by 65
The Accuracy of the Vigileo/FloTrac Continuous Cardiac Output Monitor
Zimmermann, A., Kufner, C., Hofbauer, S., Steinwendner, J., Hitzl, W., Fritsch, G., Schistek, R., Kirnbauer, M., & Pauser, G. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2007.11.001 · Cited by 64
Oesophageal Doppler monitoring overestimates cardiac output during lumbar epidural anaesthesia
Leather, H. A., & Wouters, P. F. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/86.6.794 · Cited by 63
Felbinger, T. W., Reuter, D. A., Eltzschig, H. K., Mörstedt, K., Gödje, O. L., & Goetz, A. E. (2002) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(02)00363-x · Cited by 56
Chakravarthy, M., Patil, T., Jayaprakash, K., Kalligudd, P., Prabhakumar, D., & Jawali, V. (2007) · Annals of Cardiac Anaesthesia · doi:10.4103/0971-9784.37937 · Cited by 54
Arterial Pulse Cardiac Output Agreement With Thermodilution in Patients in Hyperdynamic Conditions
Rocca, G. D., Costa, M. G., Chiarandini, P., Bertossi, G., Lugano, M., Pompei, L., Coccia, C., Sainz‐Barriga, M., & Pietropaoli, P. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2008.02.021 · Cited by 54
Imhoff, M., Lehner, J. H., & Löhlein, D. (2000) · Critical Care Medicine · doi:10.1097/00003246-200008000-00022 · Cited by 53
Evaluation of a thoracic bioimpedance cardiac output monitor during cardiac catheterization
Barin, E. S., Haryadi, D. G., Schookin, S. I., Westenskow, D. R., Zubenko, V. G., Beliaev, K. R., & Morozov, A. A. (2000) · Critical Care Medicine · doi:10.1097/00003246-200003000-00016 · Cited by 49
Critchley, L. A. H., Calcroft, R. M., Tan, P., Kew, J., & Critchley, J. (2000) · Intensive Care Medicine · doi:10.1007/s001340051232 · Cited by 49
Hirschl, M. M., Kittler, H., Woisetschläger, C., Siostrzonek, P., Staudinger, T., Kofler, J., Oschatz, E., Bur, A., Gwechenberger, M., & Laggner, A. N. (2000) · Critical Care Medicine · doi:10.1097/00003246-200006000-00017 · Cited by 47
Mutoh, T., Ishikawa, T., Nishino, K., & Yasui, N. (2009) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0b013e3181a4cd8b · Cited by 46
Kim, K., Kwak, I. S., Chang, H., & Han, T.-H. (2004) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000105925.51950.08 · Cited by 45
Evaluation of Invasive and Noninvasive Hemodynamic Monitoring in Trauma Patients
Shoemaker, W. C., Wo, C. C. J., Chien, L.-C., Lu, K., Ahmadpour, N., Belzberg, H., & Δημητριάδης, Δ. (2006) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000197925.92635.56 · Cited by 45
Improved Accuracy Of Cardiac Output Estimation By The Partial CO2 Rebreathing Method
Kotake, Y., Yamada, T., Nagata, H., et al. (2009) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-009-9172-1 · Cited by 44
Sharma, J., Bhise, M. D., Singh, A., Mehta, Y., & Trehan, N. (2005) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2004.11.038 · Cited by 43
Raue, W., Swierzy, M., Koplin, G., & Schwenk, W. (2009) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32832bfd94 · Cited by 41
Cardiac output – pulse contour analysis vs. pulmonary artery thermodilution
Østergaard, M. V., Nielsen, J., Rasmussen, J., & Berthelsen, P. G. (2006) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01080.x · Cited by 41
Is It a Bird? Is It a Plane? The Role of Patient Monitors in Medical Decision Making
Feldman, J. M. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318196c7b6 · Cited by 40
Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements
Heringlake, M., Handke, U., Hanke, T., Eberhardt, F., Schumacher, J. O., Gehring, H., & Heinze, H. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0828-3 · Cited by 39
Missant, C., Rex, S., & Wouters, P. F. (2007) · European Journal of Anaesthesiology · doi:10.1017/s0265021507002979 · Cited by 37
Measurement of cardiac output after cardiac surgery by a new transesophageal doppler device
Jaeggi, P., Hofer, C. K., Klaghofer, R., Fodor, P., Genoni, M., & Zollinger, A. (2003) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2003.50 · Cited by 36
Evaluation of a noninvasive method for cardiac output measurement in critical care patients
Murias, G. E., Villagra, A. L. R., Vatua, S., Fernandez, M. D. M., Solar, H., Ochagavía, A., Fernández, R., López‐Aguilar, J., Romero, P. V., & Blanch, L. L. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1477-1 · Cited by 35
The Effects of Vasodilation on Cardiac Output Measured by PiCCO
Yamashita, K., Nishiyama, T., Yokoyama, T., Abe, H., & Manabe, M. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2008.04.007 · Cited by 34
Lafanechère, A., Albaladejo, P., Raux, M., Geeraerts, T., Bocquet, R., Wernet, A., Castier, Y., & Marty, J. (2006) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2005.07.029 · Cited by 33
Clinical Evaluation of the HemoSonic Monitor in Cardiac Surgical Patients in the ICU
Moxon, D., Pinder, M., van Heerden, P. V., & Parsons, R. W. (2003) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0303100410 · Cited by 32
Segal, E., Katzenelson, R., Berkenstadt, H., & Perel, A. (2002) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(02)00345-8 · Cited by 31
Linton, N., & Linton, R. A. F. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/aef530 · Cited by 26
Peyton, P. J., Thompson, D., & Junor, P. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-008-9131-2 · Cited by 25
Self-citationA comparison of cardioq and thermodilution cardiac output during off-pump coronary artery surgery
HULLETT, B. J., Gibbs, N. M., Weightman, W. M., Thackray, M., & Newman, M. A. J. (2003) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2003.09.013 · Cited by 24
Staier, K., Wiesenack, C., Günkel, L., & Keyl, C. (2008) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03017593 · Cited by 23
Compton, F., Wittrock, M., Schaefer, J.-H., Zidek, W., Tepel, M., & Scholze, A. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297440.52059.2c · Cited by 20
Pulse contour cardiac output: an evaluation of the FloTrac method
Østergaard, M., Nielsen, J., & Nygaard, E. (2009) · European Journal of Anaesthesiology · doi:10.1097/eja.0b013e32831f343f · Cited by 17
Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery
Mekiš, D., Kamenik, M., Starc, V., & Jeretin, S. (2007) · European Journal of Anaesthesiology · doi:10.1017/s0265021507002669 · Cited by 17
Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output
Collins, S. É., Girard, F., Boudreault, D., Chouinard, P., Normandin, L., Couture, P., Caron, M.-J., & Ruel, M. M. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03022062 · Cited by 17
Tachibana, K., Imanaka, H., Takeuchi, M., Nishida, T., Takauchi, Y., & Nishimura, M. (2005) · Critical Care · doi:10.1186/cc3801 · Cited by 15
Comparing different methods of cardiac output determination
Bein, B., Renner, J., Scholz, J., & Tonner, P. H. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021506211128 · Cited by 13
Killick, C. J., & Parkin, W. G. (2008) · Anaesthesia and Intensive Care · doi:10.1177/0310057x0803600506 · Cited by 7
Cited by
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Checketts, M. R., Alladi, R., Ferguson, K., Gemmell, L., Handy, J. M., Klein, A. A., Love, N. J., Misra, U., Morris, C., Nathanson, M. H., et al. (2016) · Anaesthesia · doi:10.1111/anae.13316 · Cited by 490
Low-Cardiac-Output Syndrome After Cardiac Surgery
Lomivorotov, V. V., Efremov, S. M., Kirov, M. Y., Fominskiy, E. V., & Karaskov, A. M. (2017) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.05.029 · Cited by 315
Geller, B. J., Sinha, S. S., Kapur, N. K., Bakitas, M., Balsam, L. B., Chikwe, J., Klein, D. G., Kochar, A., Masri, S. C., Sims, D. B., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001076 · Cited by 274
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Metadata
- Authors
- Peyton, P. J., & Chong, S. W.
- Venue
- Anesthesiology
- Published
- 2010-11-01
- Volume
- 113
- Issue
- 5
- Pages
- 1220-1235
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2083240044
- Cited by
- 456
- References
- 85
- FWCI
- 31.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.