Invasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Noninvasive (NIBP) and intraarterial (ABP) blood pressure monitoring are used under different circumstances and may yield different values. The authors endeavored to characterize these differences and hypothesized that there could be differences in interventions associated with the use of ABP alone ([ABP]) versus ABP in combination with NIBP ([ABP+NIBP]). Methods: Simultaneous measurements of ABP and NIBP made during noncardiac cases were extracted from electronic anesthesia records; the differences were subjected to regression analysis. Records of blood products, vasopressors, and antihypertensives administered were also extracted, and associations between the use of these therapies and monitoring strategy ([ABP] vs. [ABP+NIBP]) were tested using univariate, multivariate, and propensity score matched analyses. Results: Among 24,225 cases, 63% and 37% used [ABP+NIBP] and [ABP], respectively. Systolic NIBP was likely to be higher than ABP when ABP was less than 111 mmHg and lower than ABP otherwise. Among patients with hypotension, transfusion occurred in 27% versus 43% of patients in the [ABP+NIBP] versus [ABP] group, respectively (odds ratio = 0.4; 95% CI 0.35-0.46), and 7% versus 18% of patients in the [ABP+NIBP] versus [ABP] group received vasopressor infusions, respectively (P < 0.01). Among hypertensive patients, 12% versus 44% of those in the [ABP+NIBP] versus [ABP] group received antihypertensive agents, respectively (P < 0.01). Conclusions: NIBP was generally higher than ABP during periods of hypotension and lower than ABP during periods of hypertension. The use of NIBP measurements to supplement ABP measurements was associated with decreased use of blood transfusions, vasopressor infusions, and antihypertensive medications compared with the use of ABP alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 1×
“The concordance correlation coefficients between ABP and NIBP were also calculated.(4,5) Patients with more than 20 records (5 min cumulative) of systolic ABP less than 90 mmHg were considered hypotensive, and those with systolic ABP more than 140 mmHg were considered hypertensive.”
MethodPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Kaur, B., Kaur, S., Yaddanapudi, L. N., & Singh, N. V. (2019) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000358 · Cited by 22
Metadata
- Authors
- Wax, D. B., Lin, H.-M., & Leibowitz, A. B.
- Venue
- Anesthesiology
- Published
- 2011-11-01
- Volume
- 115
- Issue
- 5
- Pages
- 973-978
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1991652362
- Cited by
- 178
- References
- 2
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Invasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring. https://app.cochat.ai/papers/10.1097/aln.0b013e3182330286
- The paper
- Wax, D. B., Lin, H.-M., & Leibowitz, A. B. (2011). Invasive and Concomitant Noninvasive Intraoperative Blood Pressure Monitoring. Anesthesiology. https://doi.org/10.1097/aln.0b013e3182330286
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.