The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Predictors and Clinical Outcomes from Failed Laryngeal Mask Airway Unique™: A Study of 15,795 Patients
Abstract
Background: Although the estimated risk of life-threatening adverse respiratory events during supraglottic airway device use is rare, the reported rate of events leading to failure of the airway device is 0.2-8%. Little is known about the risk-adjusted prediction of Laryngeal Mask Airway failure requiring rescue tracheal intubation and its impact on patient outcomes. Methods: All adult patients in whom a laryngeal mask airway (LMA Unique™, uLMA™; LMA North America, Inc., San Diego, CA) was used in ambulatory and nonambulatory anesthesia settings were included. The primary outcome was uLMA™ failure, defined as an airway event requiring uLMA™ removal and tracheal intubation. The secondary outcomes were the incidence of difficult mask ventilation and unplanned hospital admissions. Results: Of the 15,795 cases included in our study, 170 (1.1%) experienced the primary outcome of uLMA™ failure. More than 60% of patients with uLMA™ failure experienced significant hypoxia, hypercapnia, or airway obstruction, whereas 42% presented with inadequate ventilation related to leak. Four independent risk factors for failed uLMA™ were identified: surgical table rotation, male sex, poor dentition, and increased body mass index. A 3-fold increased incidence of difficult mask ventilation was observed in patients with uLMA™ failure. Among outpatients with uLMA™ failure, 13.7% had unplanned hospital admission, 5.6% of whom needed intensive care for persistent hypoxemia. Conclusions: The study supports the use of the uLMA™ as an effective supraglottic airway device with a relatively low failure rate. However, there are clinically relevant consequences of uLMA™ failure, as evidenced by the high rate of acute respiratory events and need for unplanned hospital admissions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Mushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Metadata
- Authors
- Ramachandran, S. K., Mathis, M. R., Tremper, K. K., Shanks, A. M., & Kheterpal, S.
- Venue
- Anesthesiology
- Published
- 2012-06-01
- Volume
- 116
- Issue
- 6
- Pages
- 1217-1226
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2025075387
- Cited by
- 169
- References
- 1
- FWCI
- 21.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predictors and Clinical Outcomes from Failed Laryngeal Mask Airway Unique™: A Study of 15,795 Patients. https://app.cochat.ai/papers/10.1097/aln.0b013e318255e6ab
- The paper
- Ramachandran, S. K., Mathis, M. R., Tremper, K. K., Shanks, A. M., & Kheterpal, S. (2012). Predictors and Clinical Outcomes from Failed Laryngeal Mask Airway Unique™: A Study of 15,795 Patients. Anesthesiology. https://doi.org/10.1097/aln.0b013e318255e6ab
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.