Predictors and Clinical Outcomes from Failed Laryngeal Mask Airway Unique™: A Study of 15,795 Patients
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Background: Although the estimated risk of life-threatening adverse respiratory events during supraglottic airway device use is rare, the reported rate of events leading to failure of the airway device is 0.2-8%. Little is known about the risk-adjusted prediction of Laryngeal Mask Airway failure requiring rescue tracheal intubation and its impact on patient outcomes. Methods: All adult patients in whom a laryngeal mask airway (LMA Unique™, uLMA™; LMA North America, Inc., San Diego, CA) was used in ambulatory and nonambulatory anesthesia settings were included. The primary outcome was uLMA™ failure, defined as an airway event requiring uLMA™ removal and tracheal intubation. The secondary outcomes were the incidence of difficult mask ventilation and unplanned hospital admissions. Results: Of the 15,795 cases included in our study, 170 (1.1%) experienced the primary outcome of uLMA™ failure. More than 60% of patients with uLMA™ failure experienced significant hypoxia, hypercapnia, or airway obstruction, whereas 42% presented with inadequate ventilation related to leak. Four independent risk factors for failed uLMA™ were identified: surgical table rotation, male sex, poor dentition, and increased body mass index. A 3-fold increased incidence of difficult mask ventilation was observed in patients with uLMA™ failure. Among outpatients with uLMA™ failure, 13.7% had unplanned hospital admission, 5.6% of whom needed intensive care for persistent hypoxemia. Conclusions: The study supports the use of the uLMA™ as an effective supraglottic airway device with a relatively low failure rate. However, there are clinically relevant consequences of uLMA™ failure, as evidenced by the high rate of acute respiratory events and need for unplanned hospital admissions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Updated by the Committee on Standards and Practice Parameters, Apfelbaum, J. L., Hagberg, C. A., Caplan, R. A., Blitt, C. D., Connis, R. T., Nickinovich, D. G., Hagberg, C. A., The previous update was developed by the American Society of Anesthesiologists Task Force on Difficult Airway Management, Caplan, R. A., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31827773b2 · Cited by 2,559
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Difficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
The Risk of Determining Risk with Multivariable Models
Concato, J., Feinstein, A. R., & Holford, T. R. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-118-3-199302010-00009 · Cited by 1,115 · cited 2×
“In addition, we limited the analyzed variables to prevent regression model over-fitting.(25) It should be noted that an unmeasured selection bias existed for the patient population, which may have influenced the primary choice of uLMATM over a endotracheal tube.”
BackgroundMethodStatistics review 14: Logistic regression.
Bewick, V., Cheek, L., & Ball, J. (2005) · Critical Care · doi:10.1186/cc3045 · Cited by 716 · cited 2×
“The Omnibus test was used to evaluate the goodness of fit by the presence of statistically significant differences between the explained and unexplained variance within the model.(22) The resultant chi-square statistic value is a measure of the relationship between observed and expected frequencies.”
BackgroundMethodIncidence and Predictors of Difficult and Impossible Mask Ventilation
Kheterpal, S., Han, R., Tremper, K. K., Shanks, A., Tait, A. R., O’Reilly, M., & Ludwig, T. A. (2006) · Anesthesiology · doi:10.1097/00000542-200611000-00007 · Cited by 655 · cited 1×
“Airway-related variables included modified Mallampati class 3–4, reduced thyromental distance estimated less than 6 cm,(11,12) reduced mouth opening estimated less than 3 cm,(13) inability to protrude lower incisors anterior to upper incisors,(11,13) qualitatively assessed thick neck,(12,15) beard presence,(13) clinic…”
MethodSelf-citationThe airway: problems and predictions in 18,500 patients
Rose, D. K., & Cohen, M. M. (1994) · Canadian Journal of Anaesthesia · doi:10.1007/bf03009858 · Cited by 645
Prediction and Outcomes of Impossible Mask Ventilation: A Review of 50,000 Anesthetics
Kheterpal, S., Martin, L., Shanks, A. M., & Tremper, K. K. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819b5b87 · Cited by 467 · cited 1×
“Through a consistent recording of these data, a searchable database for observational research has been established and recently used in multiple large-scale clinical studies.(11,12) From this prospectively populated computerized database, a search query was performed to obtain all relevant data for this study.”
MethodSelf-citationThe advantages of the LMA over the tracheal tube or facemask: a meta-analysis
Brimacombe, J. R. (1995) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03011075 · Cited by 376 · cited 1×
“Recent upper respiratory tract infections, asthma, chronic obstructive pulmonary disease, and current smoking also were assessed both individually and collapsed as one variable because hyperreactive airways have been shown to be associated with an increased incidence of adverse respiratory events with LMA anesthesia.(…”
Method
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Guidelines for the management of tracheal intubation in critically ill adults
Higgs, A., McGrath, B. A., Goddard, C., Rangasami, J., Suntharalingam, G., Gale, R., & Cook, T. M. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.10.021 · Cited by 900
Mushambi, M. C., Kinsella, S. M., Popat, M., Swales, H., Ramaswamy, K. K., Winton, A. L., & Quinn, A. C. (2015) · Anaesthesia · doi:10.1111/anae.13260 · Cited by 608
Complications and failure of airway management
Cook, T. M., & MacDougall-Davis, S. R. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes393 · Cited by 525
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Failed tracheal intubation during obstetric general anaesthesia: a literature review
Kinsella, S. M., Winton, A. L., Mushambi, M. C., Ramaswamy, K., Swales, H., Quinn, A. C., & Popat, M. (2015) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2015.06.008 · Cited by 333
The difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Kovacs, G., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02008-z · Cited by 203
Memtsoudis, S. G., Cozowicz, C., Nagappa, M., Wong, J., Joshi, G. P., Wong, D. T., Doufas, A. G., Yilmaz, M., Stein, M. H., Krajewski, M. L., et al. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003434 · Cited by 186
Self-citationStrategies for the prevention of airway complications – a narrative review
Cook, T. M. (2018) · Anaesthesia · doi:10.1111/anae.14123 · Cited by 167
Metadata
- Authors
- Ramachandran, S. K., Mathis, M. R., Tremper, K. K., Shanks, A. M., & Kheterpal, S.
- Venue
- Anesthesiology
- Published
- 2012-06-01
- Volume
- 116
- Issue
- 6
- Pages
- 1217-1226
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2025075387
- Cited by
- 169
- References
- 22
- FWCI
- 21.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.