Capnography Outside the Operating Rooms
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
HISTORICALLY, anesthesiologists seem to be the forerunners in implementing tools and standards for safety in the medical fraternity. In the United States, since 1985, there has been a dramatic decrease in the malpractice insurance premiums of anesthesiologists. Such a decrease has not been seen in other medical or surgical specialties over this time frame. Thanks to the foresight of the American Society of Anesthesiologists (ASA), Anesthesia Patient Safety Foundation (APSF), Association of Anaesthetists of Great Britain and Ireland (AAGBI), and the Association of Anesthesiologists in Holland, capnography was embraced and incorporated into the standards of monitoring during anesthesia to enhance patient safety. Currently, anesthesiologists in many developing countries follow these recommendations (India, Government of Andhra Pradesh Order, AST/775/F25/dated September 2011. Capnography is mandatory for laparoscopic surgeries for reimbursement). Although capnography has become an integral part of anesthesia care in operating rooms for more than 25 yr, its value has been limited to these situations and is not well appreciated beyond these confinements. It is not uncommon in our practice to observe an intubated and ventilated patient, originally monitored with capnography in the operating room, but then transported to the intensive care unit (ICU) without capnography. It is even more surprising that many ICUs do not have capnography either to confirm endotracheal intubation or to continually monitor ventilation. As anesthesiologists, we use capnography to monitor sedation in the operating room because we appreciate that the line between consciousness and unconsciousness is very thin, and the patient can drift from one state to another. However, in many institutions, capnography is not used to monitor ventilation during sedation for procedures performed particularly by nonanesthesiologists outside of the operating rooms. One of the obvious reasons seems to be a lack of a single society overseeing the safety of outside-the-operating-room procedures the way ASA and AAGBI do in the operating room. Nonetheless, in the last 2 yr there has been a surge in understanding and recognizing the value of capnography outside of the operating rooms.1,2This “Clinical Concepts and Commentary” will summarize physiology and clinical interpretation of capnography and update the current status of capnography outside of the operating rooms, including public and media awareness, and suggest probable future directions.Infrared technology is by far the most common and cost-effective method of carbon dioxide measurement and monitoring. Efforts have been made to decrease the response time and increase the accuracy of infrared technology to produce superior capnography waveforms even in premature babies with small tidal volumes and rapid respiratory rates.3The carbon dioxide values are usually displayed as partial pressure (PCO2). Depending on the location of the carbon dioxide measuring device, there are two sensor types: mainstream and sidestream. In mainstream sensors, the adaptor housing the sensor is interposed between the tracheal tube and breathing circuit, and the measurement of carbon dioxide is made across the airway. In sidestream technology, the respiratory gases are aspirated via an adaptor and a 6-foot sampling tube to the monitor housing the infrared sensor. The transport of gases to the infrared measuring device results in a delay of 1–4 s in carbon dioxide measurement and display of capnograms in sidestream capnography.A conventional capnogram in adults results in a more or less identical shape in all healthy individuals. Any variation from this requires an analysis to determine a physiologic or pathologic cause of the variation. Carbon dioxide waveforms can be plotted against time (time capnogram, fig. 1A) or expired volume (volumetric capnogram, fig. 1B). Time capnography is used more commonly in clinical practice. A time capnogram has two important segments: inspiratory (phase 0) and expiratory.4–6The expiratory segment is further divided into three phases (I, II, III), and an occasional phase IV (fig. 1C), based on the physiology of carbon dioxide evolution from the lungs and airways. Phase I does not contain any expired carbon dioxide (dead space gases, zero PCO2). In phase II, the PCO2rises rapidly as carbon dioxide–laden alveolar gas replaces zero-carbon dioxide dead space gas. Phase III is the alveolar plateau that represents the evolution of carbon dioxide from alveoli. If all the alveoli had the same PCO2, the alveolar plateau would be perfectly flat. In reality, there is a considerable spatial and temporal mismatch in the lungs resulting in variable V/Q ratios and thus, variable PCO2. Usually the alveoli with lower V/Q ratios and with longer time constants (containing relatively more carbon dioxide) contribute to the later part of phase III. This results in a slight upward slope of the alveolar partial pressure “
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cook, T. M., Woodall, N., & Frerk, C. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer058 · Cited by 2,415
Cook, T. M., Woodall, N., Harper, J., & Benger, J. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer059 · Cited by 1,065
Cited by
Big Data In Health Care: Using Analytics To Identify And Manage High-Risk And High-Cost Patients
Bates, D. W., Saria, S., Ohno-Machado, L., Shah, A., & Escobar, G. (2014) · Health Affairs · doi:10.1377/hlthaff.2014.0041 · Cited by 1,235
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919
“Several reasons have been enumerated by Shankar [58] from Harvard Medical School to explain why capnography should be considered a routine monitor, highlighting that this method can be used as a guide to metabolic rate, or as an essential adjunct to monitor the integrity of airway, cardiac output and ventilation.”
BackgroundMethodInfluential
Metadata
- Authors
- Kodali, B. S.
- Venue
- Anesthesiology
- Published
- 2013-01-01
- Volume
- 118
- Issue
- 1
- Pages
- 192-201
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2151592172
- Cited by
- 158
- References
- 2
- FWCI
- 13.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capnography Outside the Operating Rooms. https://app.cochat.ai/papers/10.1097/aln.0b013e318278c8b6
- The paper
- Kodali, B. S. (2013). Capnography Outside the Operating Rooms. Anesthesiology. https://doi.org/10.1097/aln.0b013e318278c8b6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.