Obstructive Sleep Apnea in Pregnancy: Assessment of Current Screening Tools
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To estimate the predictive ability of current obstructive sleep apnea (OSA) screening tools and the individual questions in these tools at identifying pregnant women who have OSA. METHODS: A total of 293 third-trimester patients were enrolled between 2010 and 2012, and 248 patients had sleep monitor results. Recruited participants completed a questionnaire consisting of six OSA screening tools and overnight portable sleep monitoring. Predictive ability of the screening tools for OSA compared with results of the diagnosis from overnight sleep monitoring was estimated using the area under receiver operating characteristic curves. RESULTS: Two hundred eighteen (88%) of the patients were OSA-negative, and 30 patients (12%) were OSA-positive based on sleep monitoring results. Compared with OSA-negative patients, OSA-positive patients had greater body mass indices and neck circumferences as well as significantly higher rates of hypertension (chronic and gestational), pregestational diabetes mellitus, asthma, and preeclampsia. The overall predictive ability of the screening tools for OSA was modest (area under receiver operating characteristic curves 0.62-0.695). However, individual components of the questionnaire were strongly associated with OSA. CONCLUSION: We found that none of the studied OSA screening tools accurately detected OSA in pregnant women in the third trimester. We have identified proposed elements of a new screening tool based on promising components from several tools that may more accurately detect patients with OSA. LEVEL OF EVIDENCE: II.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cicchetti, D. V. (1994) · Psychological Assessment · doi:10.1037/1040-3590.6.4.284 · Cited by 9,349
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355 · cited 1×
“034 Gestational 20 (8) 15 (7) 5 (17) NS Asthma 54 (22) 42 (19) 12 (40) .”
High STOP-Bang score indicates a high probability of obstructive sleep apnoea
Chung, F., Subramanyam, R., Liao, P., Sasaki, E., Shapiro, C., & Sun, Y. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes022 · Cited by 988
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d91b5 · Cited by 571
Risk factors for sleep-disordered breathing in pregnancy
Pien, G. W., Pack, A. I., Jackson, N., Maislin, G., Macones, G. A., & Schwab, R. J. (2014) · Thorax · doi:10.1136/thoraxjnl-2012-202718 · Cited by 281 · cited 3×
“001 Hypertension (chronic or gestational) 68 (27) 51 (23) 17 (57) ,.”
Louis, J. M., Mogos, M. F., Salemi, J. L., Redline, S., & Salihu, H. M. (2014) · Sleep · doi:10.5665/sleep.3644 · Cited by 279
Effects of maternal obstructive sleep apnoea on fetal growth: a prospective cohort study
Fung, A. M., Wilson, D. L., Lappas, M., Howard, M., Barnes, M., O'Donoghue, F., Tong, S., Esdale, H., Fleming, G., & Walker, S. P. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068057 · Cited by 119
Cited by
Chung, F., Memtsoudis, S. G., Ramachandran, S. K., Nagappa, M., Opperer, M., Cozowicz, C., Patrawala, S., Lam, D., Kumar, A., Joshi, G. P., et al. (2016) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001416 · Cited by 360
“126 135 Unfortunately, screening tools appear less accurate and have not been validated in the obstetric population, 136 and currently, there are no pregnancy-specific guidelines for the diagnosis and treatment of OSA.”
MethodLu, Q., Zhang, X., Wang, Y., Li, J., Xu, Y., Song, X., Su, S., Zhu, X., Vitiello, M. V., Shi, J., et al. (2021) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2021.101436 · Cited by 311
Liu, L., Su, G., Wang, S., & Zhu, B. (2019) · Sleep and Breathing · doi:10.1007/s11325-018-1714-7 · Cited by 124
Predictors of sleep-disordered breathing in pregnancy
Louis, J. M., Koch, M. A., Reddy, U. M., Silver, R. M., Parker, C. B., Facco, F. L., Redline, S., Nhan-Chang, C.-L., Chung, J. H., Pien, G. W., et al. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.01.031 · Cited by 106
Maternal Sleep-Disordered Breathing
Pamidi, S., & Kimoff, R. J. (2018) · Chest · doi:10.1016/j.chest.2017.10.011 · Cited by 61
Metadata
- Authors
- Lockhart, E. M., Ben Abdallah, A., Tuuli, M. G., & Leighton, B. L.
- Venue
- Obstetrics & Gynecology
- Published
- 2015-07
- Volume
- 126
- Issue
- 1
- Pages
- 93-102
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1074283636
- Cited by
- 88
- References
- 7
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Obstructive Sleep Apnea in Pregnancy: Assessment of Current Screening Tools. https://app.cochat.ai/papers/10.1097/aog.0000000000000848
- The paper
- Lockhart, E. M., Ben Abdallah, A., Tuuli, M. G., & Leighton, B. L. (2015). Obstructive Sleep Apnea in Pregnancy: Assessment of Current Screening Tools. Obstetrics & Gynecology. https://doi.org/10.1097/aog.0000000000000848
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.