CoChat

Psychometric Properties and Factor Structure of a New Scale to Measure Hyperacusis: Introducing the Inventory of Hyperacusis Symptoms

Greenberg, Benjamin, Carlos, Megan · 2018 · Ear & Hearing
Cited by 81

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

Objectives: Despite increasing interest in hyperacusis and other disorders of auditory sensitivity, there is still a lack of valid, standardized assessment tools to measure symptom severity, treatment outcomes, and diagnostic differentiation. Accordingly, this study sought to create a new scale that is reliable, valid, brief, and easy to score with the purpose of filling this gap. Design: Original items were constructed through review of currently existing models of hyperacusis measurement, as well as qualitative data collected from professional audiologists and individuals reporting heightened audiological sensitivity with tinnitus. An initial 26-item scale yielded sound reliability and validity properties. Refinement based on review of initial data resulted in a 25-question second version with a maximum score of 100. A total of 450 completed survey protocols were analyzed from 469 refined Inventory of Hyperacusis Symptoms (IHS) administrations collected online, representing individuals from 37 countries with a mean age of 34.8 years. Results: Internal consistency reliability analysis yielded a Cronbach’s α of 0.93, indicating excellent reliability. Furthermore, the IHS showed sound convergent validity with established measures of quality of life, anxiety, and depression in bivariate correlation analysis of Pearson’s r. Factor analysis revealed a dimensional structure containing five factors, which were designated psychosocial impact, emotional arousal, functional impact, general loudness, and communication. Analysis of variance between perceived global hyperacusis severity categories provided a preliminary framework for scoring thresholds. Although the level of hearing loss did not correlate with IHS scores, increased tinnitus symptoms were a significant factor in predicting hyperacusis distress and severity. Conclusions: These initial results demonstrated sound statistical properties of the IHS and usefulness as a hyperacusis measurement tool in research and clinical practice. Factor structure and scale dimensions allow for differentiation between subtypes of loudness, annoyance, fear, and pain based on responses to clusters of specific items within the dimensional factor structure of the scale, and may thus prove useful in clinical practice and research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aud.0000000000000583

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

Metadata

Authors
Greenberg, B., & Carlos, M.
Venue
Ear & Hearing
Published
2018-09
Volume
39
Issue
5
Pages
1025-1034
ISSN
0196-0202 (ISSN-L)
OpenAlex
W2800443505
Cited by
81
References
21
FWCI
2.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Psychometric Properties and Factor Structure of a New Scale to Measure Hyperacusis: Introducing the Inventory of Hyperacusis Symptoms. https://app.cochat.ai/papers/10.1097/aud.0000000000000583
The paper
Greenberg, B., & Carlos, M. (2018). Psychometric Properties and Factor Structure of a New Scale to Measure Hyperacusis: Introducing the Inventory of Hyperacusis Symptoms. Ear & Hearing. https://doi.org/10.1097/aud.0000000000000583

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.