Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 178

The DOI matches its Crossref record.

Current Steering and Current Focusing in Cochlear Implants: Comparison of Monopolar, Tripolar, and Virtual Channel Electrode Configurations

Berenstein, Carlo K., Mens, Lucas H. M., Mulder, Jef J. S., Vanpoucke, Filiep J. · 2008 · Ear & Hearing

Abstract

In Brief Objectives: To compare the effects of Monopole (Mono), Tripole (Tri), and “Virtual channel” (Vchan) electrode configurations on spectral resolution and speech perception in a crossover design. Design: Nine experienced adults who received an Advanced Bionics CII/90K cochlear implant participated in a crossover design using three experimental strategies for 2 wk each. Three strategies were compared: (1) Mono; (2) Tri with current partly returning to adjacent electrodes and partly (25 or 75%) to the extracochlear reference; and (3) a monopolar “Vchan” strategy creating seven intermediate channels between two contacts. Each strategy was a variant of the standard “HiRes” processing strategy using 14 channels and 1105 pulses/sec/channel, and a pulse duration of 32 μsec/phase. Spectral resolution was measured using broadband noise with a sinusoidally rippled spectral envelope with peaks evenly spaced on a logarithmic frequency scale. Speech perception was measured for monosyllables in quiet and in steady-state and fluctuating noises. Subjective comments on music experience and preferences in everyday use were assessed through questionnaires. Results: Thresholds and most comfortable levels with Mono and Vchan were both significantly lower than levels with Tri. Spectral resolution was significantly higher with Tri than with Mono; spectral resolution with Vchan did not differ significantly from the other configurations. Moderate but significant correlations between word recognition and spectral resolution were found in speech in quiet and fluctuating noise. For speech in quiet, word recognition was best with Mono and worst with Vchan; Tri did not significantly differ from the other configurations. Pooled across the noise conditions, word recognition was best with Tri and worst with Vchan (Mono did not significantly differ from the other configurations). These differences were small and insufficient to result in a clear increase in performance across subjects if the result from the best configuration per subject was compared with the result from Mono. Across all subjects, music appreciation and satisfaction in everyday use did not clearly differ between configurations. Conclusions: (1) Although spectral resolution was improved with the tripolar configuration, differences in speech performance were too small in this limited group of subjects to justify clinical introduction. (2) Overall spectral resolution remained extremely poor compared with normal hearing; it remains to be seen whether further manipulations of the electrical field will be more effective. Compared to Monopolar stimulation currently used in cochlear implants, Tripolar stimulation has been shown to increase spatial selectivity in animal studies. The “Virtual channels” approach attempts to increase spectral resolution by providing a high number of effectively Monopolar channels. In this study, we compared the effects of Monopole, Tripole, and “Virtual channel” electrode configurations on spectral resolution and on speech perception using a crossover design in nine adults who received an Advanced Bionics CII/90K cochlear implant. “Hybrid” Tripolar configurations had to be used with current partly flowing to the extracochlear reference to enable sufficient loudness growth. Although spectral resolution improved slightly with the Tripolar configuration, the differences were small in this limited group of subjects. More efficient stimulation schemes are necessary for future testing of Tripolar stimulation benefits.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aud.0b013e3181645336

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Berenstein, C. K., Mens, L. H. M., Mulder, J. J. S., & Vanpoucke, F. J.
Venue
Ear & Hearing
Published
2008-04
Volume
29
Issue
2
Pages
250-260
ISSN
0196-0202 (ISSN-L)
OpenAlex
W2120790466
Cited by
178
References
0
FWCI
4.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current Steering and Current Focusing in Cochlear Implants: Comparison of Monopolar, Tripolar, and Virtual Channel Electrode Configurations. https://app.cochat.ai/papers/10.1097/aud.0b013e3181645336
The paper
Berenstein, C. K., Mens, L. H. M., Mulder, J. J. S., & Vanpoucke, F. J. (2008). Current Steering and Current Focusing in Cochlear Implants: Comparison of Monopolar, Tripolar, and Virtual Channel Electrode Configurations. Ear & Hearing. https://doi.org/10.1097/aud.0b013e3181645336

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.