Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 290

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation

Lujan, Trevor J, Henderson, Chris E, Madey, Steven M, Fitzpatrick, Dan C, Marsh, J Lawrence, Bottlang, Michael·2010·Journal of Orthopaedic Trauma

Abstract

OBJECTIVES: Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. DESIGN: Retrospective cohort study. SETTING: One Level I and one Level II trauma center. PATIENTS: Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. INTERVENTION: Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. MAIN OUTCOME MEASUREMENT: Periosteal callus size on lateral and anteroposterior radiographs. RESULTS: Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. CONCLUSIONS: Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/bot.0b013e3181be6720

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 290

Metadata

Authors
Lujan, T. J., Henderson, C. E., Madey, S. M., Fitzpatrick, D. C., Marsh, J. L., & Bottlang, M.
Venue
Journal of Orthopaedic Trauma
Published
2010-03
Volume
24
Issue
3
Pages
156-162
ISSN
0890-5339 (ISSN-L)
OpenAlex
W2003465489
Cited by
290
References
27
FWCI
10.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation. https://app.cochat.ai/papers/10.1097/bot.0b013e3181be6720
The paper
Lujan, T. J., Henderson, C. E., Madey, S. M., Fitzpatrick, D. C., Marsh, J. L., & Bottlang, M. (2010). Locked Plating of Distal Femur Fractures Leads to Inconsistent and Asymmetric Callus Formation. Journal of Orthopaedic Trauma. https://doi.org/10.1097/bot.0b013e3181be6720

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.